Muntean Daniel Beniamin

Prof. Muntean Daniel Beniamin

Building Services, Politehnica University Timișoara, Timişoara, Timiş, Romania
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
ATAdriana Tokar
Adriana Tokar
MBMuntean Daniel Beniamin
Muntean Daniel Beniamin
DTDanut Tokar
Danut Tokar
DBDaniel Bisorca
Daniel Bisorca
The study was carried out to evaluate theoretically and in laboratory conditions the capacity of a hybrid heating and cooling system that sustainably uses thermal energy extracted from surface waters in order to decarbonize buildings located near water sources. The novelty of the research consists in the realization of two experimental systems, one for the rapid evaluation of the performance of the water–water heat pump heating system and one for the evaluation of the operating behavior of a cooling system with fan coil units. Starting with the heating and cooling demand, and the climatic and hydrological local characteristics, a hybrid system model for the heating and cooling of the analyzed building was established and implemented. The forecasted energy consumption and CO2 emissions for the operation of the new equipment were compared with the historical values of the old systems with which the building was equipped (thermal energy supply from the district heating and cooling system with an air conditioning unit). Also, the results were extrapolated for forecasting the energy potential of the surface waters. The study highlights a percentage reduction in annual energy consumption of 67.71% and CO2 emissions of 80.13% through the implementation of the hybrid system.

21 January 2026 in Buildings
Verified
Journal Article
Open access
PDF file
ATAdriana Tokar
Adriana Tokar
MBMuntean Daniel Beniamin
Muntean Daniel Beniamin
DTDanut Tokar
Danut Tokar
DBDaniel Bisorca
Daniel Bisorca
One of the important stages of energy efficiency measures for buildings is the optimal choice of heating and cooling systems, as well as that of heat/cold production sources, so as to minimize dependence on conventional fuels and the national energy system. Currently, the option for integrating renewable energy sources addressed in the building efficiency stage is the installation of solar systems. In the context of the need to reduce energy consumption and reduce pollutant emissions, and the need to integrate renewable energy sources, the article addresses the implementation of a hybrid system with a water-to-water heat pump and photovoltaic panels, capable of achieving the decarbonization of the heating/cooling of a University Politehnica Timisoara teaching/research laboratory. The analyzed hybrid system uses the thermal potential of the Bega channel as a heat/cold source, and as a source for electricity production, a PV system, supported by the national energy system. Following the analysis of the operation of the building’s hybrid system for heating and cooling, during 4 November 2024–12 September 2025, an energy independence of approximately 90.7% and a reduction in CO2 emissions of 4.17 t/year was found.

29 September 2026 in Toxics
Verified
Journal Article
Open access
PDF file
ATAdriana Tokar
Adriana Tokar
DBDaniel Bisorca
Daniel Bisorca
DTDanut Tokar
Danut Tokar
MBMuntean Daniel Beniamin
Muntean Daniel Beniamin
ATAndreea-Miruna Tokar
Andreea-Miruna Tokar
The need to build multistory parking in congested areas of cities presents new challenges regarding the estimation of the impact of these investments on the environment and neighboring buildings. The authors synthesize the data available in the official EU documentation and in the scientific literature and propose a method for calculating polluting gaseous emissions generated in multistory car parks. For the case study targeting the MB-UPT car park, a scheme with functional blocks was created, with elements that quantitatively and qualitatively influence the polluting gaseous emissions (CO, CO2, NMVOC, NOx, NH3) generated by the operation of the car park. The study considers a fleet of motor vehicles with characteristics like those of the motor vehicles in the car park in Timiș County. The calculation method was applied considering three operating scenarios with high-level emissions, estimated to be encountered in real operation. Considering the operating modes of the motor vehicles, emission factors and correction coefficients were chosen for the highest possible degree of confidence in the emission estimates. The results are presented graphically and in tabular form. From the analysis of the results, for each pollutant species analyzed, the relevant critical factor was determined in the context of the three scenarios. The method proposed by the authors allows for the quantitative determination of polluting gaseous emissions and easy identification of episodes and zones with high emissions.

9 April 2026 in Buildings
Verified
Journal Article
Open access
PDF file
ATAdriana Tokar
Adriana Tokar
MBMuntean Daniel Beniamin
Muntean Daniel Beniamin
DTDanut Tokar
Danut Tokar
To achieve climate neutrality by 2050, new buildings, but also approximately 75% of the existing building stock in the EU, must begin the transition process towards decarbonization. The article models, analyses, develops and experimentally tests a hybrid technical system that provides heating, cooling and hot water for an educational building located in Timisoara, Romania. The hybrid system was designed by the authors to integrate renewable technologies for reducing operational CO2 emissions generated by technical systems in tertiary buildings. The hybrid system can provide, by PV system, 17.94% of hot water and heating agent for the winter season, and 78.61% of hot water and chilled water for building cooling in the summer season. The results obtained show a decrease in electricity consumption from the national energy system of 2.5 MWh. In terms of operational CO2 emissions, there was a reduction of 84.47% when compared with the classic system in which the building was connected to the city’s centralized system, which is currently dependent on fossil fuels (a coal and gas addition of approximately 10–15%).