Daniel Bisorca

Dr. Daniel Bisorca

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
DMDan-Marius Mustață
Dan-Marius Mustață
DBDaniel Bisorca
Daniel Bisorca
Ioana IonelIoana Ionel
Ioana Ionel
AHMED ADJALAHMED ADJAL
AHMED ADJAL
BBBalogh Balogh
Balogh Balogh
This study presents real-time measurements of particulate matter (PM1, PM2.5, PM10) and carbon dioxide (CO2) concentrations across five university indoor environments with varying occupancy levels and natural ventilation conditions. CO2 concentrations frequently exceeded the 1000 ppm guideline, with peak values reaching 3018 ppm and 2715 ppm in lecture spaces, whereas one workshop environment maintained levels well below limits (mean = 668 ppm). PM concentrations varied widely: PM10 reached 541.5 µg/m3 in a carpeted amphitheater, significantly surpassing the 50 µg/m3 legal daily limit, while a well-ventilated classroom exhibited lower levels despite moderate occupancy (PM10 max = 116.9 µg/m3). Elevated PM values were strongly associated with flooring type and occupant movement, not just activity type. Notably, window ventilation during breaks reduced CO2 concentrations by up to 305 ppm (p < 1 × 10−47) and PM10 by over 20% in rooms with favorable layouts. These findings highlight the importance of ventilation strategy, spatial orientation, and surface materials in shaping indoor air quality. The study emphasizes the need for targeted, non-invasive interventions to reduce pollutant exposure in historic university buildings where mechanical ventilation upgrades are often restricted.

1 February 2022 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
RCR V Corlan
R V Corlan
Ioana IonelIoana Ionel
Ioana Ionel
MBMaria Elena Boatca
Maria Elena Boatca
Anca DraghiciAnca Draghici
Anca Draghici
RBR M Balogh
R M Balogh
DBDaniel Bisorca
Daniel Bisorca
Improving conditions and quality of life depends, among others, on the environment. People spend most of their time in a day inside buildings to work, sleep, eat, rest, and do sports and other activities. The article refers to a case study based on research on indoor environment within a furniture factory; the research is achieved via instruments for collecting diverse indoor parameters, such as temperature, CO2, PM (particulate matter) concentrations, noise, and humidity levels. All data recorded are needed to evaluate the conditions of the indoor climate in which the workers are activating. The measuring methods are shortly introduced and the IAQ (indoor air quality) index is expressed. The personnel activating in this factory is working intensely, standing up, and having to wear a mask considering the Covid-19 context. Thus, it is important to depict each aspect that might trigger a concern if IAQ limits are over passed, not mentioning the synergetic context of the diverse effects. Through revealing the IAQ, and the comfort/discomfort level PMV/PPD (predicted mean vote and predicted percentage dissatisfied) employees and company management can benefit from this awareness and enhance the behaviour in such a way that one might improve the indoor condition. The rapid and irreversible climate changes, mostly due to increasing pollution level and exhaust of greenhouse gases should push humanity to make more studies of this kind and, accordingly, realize the need of improvement and development of new solutions whereby one can sustain the indoor environment as proper as possible, in addition to the outdoor climate.

25 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
ATAdriana Tokar
Adriana Tokar
MBMuntean Daniel Beniamin
Muntean Daniel Beniamin
DTDanut Tokar
Danut Tokar
DBDaniel Bisorca
Daniel Bisorca
The study was carried out to evaluate theoretically and in laboratory conditions the capacity of a hybrid heating and cooling system that sustainably uses thermal energy extracted from surface waters in order to decarbonize buildings located near water sources. The novelty of the research consists in the realization of two experimental systems, one for the rapid evaluation of the performance of the water–water heat pump heating system and one for the evaluation of the operating behavior of a cooling system with fan coil units. Starting with the heating and cooling demand, and the climatic and hydrological local characteristics, a hybrid system model for the heating and cooling of the analyzed building was established and implemented. The forecasted energy consumption and CO2 emissions for the operation of the new equipment were compared with the historical values of the old systems with which the building was equipped (thermal energy supply from the district heating and cooling system with an air conditioning unit). Also, the results were extrapolated for forecasting the energy potential of the surface waters. The study highlights a percentage reduction in annual energy consumption of 67.71% and CO2 emissions of 80.13% through the implementation of the hybrid system.


21 January 2026 in Buildings
Verified
Journal Article
Open access
PDF file
ATAdriana Tokar
Adriana Tokar
MBMuntean Daniel Beniamin
Muntean Daniel Beniamin
DTDanut Tokar
Danut Tokar
DBDaniel Bisorca
Daniel Bisorca
One of the important stages of energy efficiency measures for buildings is the optimal choice of heating and cooling systems, as well as that of heat/cold production sources, so as to minimize dependence on conventional fuels and the national energy system. Currently, the option for integrating renewable energy sources addressed in the building efficiency stage is the installation of solar systems. In the context of the need to reduce energy consumption and reduce pollutant emissions, and the need to integrate renewable energy sources, the article addresses the implementation of a hybrid system with a water-to-water heat pump and photovoltaic panels, capable of achieving the decarbonization of the heating/cooling of a University Politehnica Timisoara teaching/research laboratory. The analyzed hybrid system uses the thermal potential of the Bega channel as a heat/cold source, and as a source for electricity production, a PV system, supported by the national energy system. Following the analysis of the operation of the building’s hybrid system for heating and cooling, during 4 November 2024–12 September 2025, an energy independence of approximately 90.7% and a reduction in CO2 emissions of 4.17 t/year was found.

4 February 2026 in Chemosensors
Verified
Journal Article
Open access
PDF file
DMDan-Marius Mustață
Dan-Marius Mustață
Ioana IonelIoana Ionel
Ioana Ionel
DBDaniel Bisorca
Daniel Bisorca
VNVenera-Stanca Nicolici
Venera-Stanca Nicolici
Roadside public transport stops represent localized air pollution hotspots where short-term exposure may differ substantially from levels reported by urban background monitoring. This study investigates the application of low-cost air quality sensors for long-term characterization of particulate matter and gaseous pollutants in a traffic-dominated urban microenvironment. The novelty of this work lies in the combined use of collocated low-cost sensors, energy-independent solar-powered deployment, height-resolved placement representative of different breathing zones, and integrated statistical and predictive analysis to resolve exposure-relevant pollutant dynamics at a single transport stop. Hourly concentrations of particulate matter (PM) PM1, PM2.5, PM10, nitrogen dioxide (NO2), and ozone (O3) were measured over one year at a roadside transport stop adjacent to a four-lane urban road carrying approximately 30,000 vehicles per day. Measurements were obtained using two collocated low-cost sensor units based on optical particle sensing for particulate matter and electrochemical sensing for gases, together with concurrent meteorological observations. Strong agreement between the two particulate matter sensors supported the use of averaged concentrations. Mean PM2.5 concentrations were substantially higher in winter (32.4 µg/m3) than in summer (10.4 µg/m3), indicating pronounced seasonal variability. PM1 and PM2.5 exhibited closely aligned temporal patterns, while PM10 showed greater variability. NO2 displayed sharp diurnal peaks associated with traffic activity, whereas O3 exhibited opposing seasonal and diurnal behavior and was negatively correlated with both PM2.5 (r = −0.32) and NO2 (r = −0.29). One-hour-ahead predictive models incorporating meteorological and temporal variables achieved coefficients of determination up to 0.84. The results demonstrate that energy-independent low-cost sensor systems can robustly capture temporal patterns, pollutant interactions, and short-term predictability in localized roadside environments relevant to exposure assessment.