Natural zeolite clinoptilolite was successfully applied in the sensing technology for electrochemical detection of ammonium. A novel ammonium-selective sensor was developed based on clinoptilolite, possessing intrinsic ammonium-sieving and ion exchange capacity. The sensor design allowed measurements in both differential mode and requiring no classical reference electrode. The sensor selectivity towards Na+, K+, Ca2+, Mg2+, and Al3+ was studied. The limit of detection and the dynamic range of the ammonium-selective conductometric microsensor, determined in the phosphate buffer solution, were 1.0 × 10−8 M and 0–8 mM, respectively. The ammonium sensor presented high operational and storage stability.
The conductometric sensor based on 25,27-di-(5-thio-octyloxy)calix[4]arene-crown-6 was developed for the quantitative analysis of ammonium. The calixarene was immobilized on the surface of the planar interdigitated electrodes by attachment of its dialkyl sulfide groups to the surface of the gold electrodes. The intrinsic ability of the calixarene to capture ammonium was studied in the conductometric measuring mode and by the electrochemical impedance spectroscopy. The developed sensor showed high selectivity to ammonium in the presence of mono-, di-, and trivalent cations. Selective and highly sensitive detection of ammonium resulted from the complexation between the ammonium ions and a crown-ether fragment of the upper rim of the 25,27-di-(5-thio-octyloxy)calix[4]arene-crown-6 macrocycle. The developed sensor had high signal repeatability. Its sensitivity was found to be satisfactory for the forthcoming sensor application in the water-sample analysis; the linear range was 0.01–1.5 mM and limit of detection 10 μM.
The present study reports on the development, adaptation, and optimization of a novel monoenzyme conductometric biosensor based on a recombinant arginine deiminase (ADI) for the determination of arginine in dietary supplements with a high accuracy of results. Aiming for the highly sensitive determination of arginine in real samples, we studied the effect of parameters of the working buffer solution (its pH, buffer capacity, ionic strength, temperature, and protein concentration) on the sensitivity of the biosensor to arginine. Thus, it was determined that the optimal buffer is a 5 mM phosphate buffer solution with pH 6.2, and the optimal temperature is 39.5 °C. The linear functioning range is 2.5–750 µM of L-arginine with a minimal limit of detection of 2 µM. The concentration of arginine in food additive samples was determined using the developed ADI-based biosensor. Based on the obtained results, the most effective method of biosensor analysis using the method of standard additions was chosen. It was also checked how the reproducibility of the biosensor changes during the analysis of pharmaceutical samples. The results of the determination of arginine in real samples using a conductometric biosensor based on ADI clearly correlated with the data obtained using the method of ion-exchange chromatography and enzymatic spectrophotometric analysis. We concluded that the developed biosensor would be effective for the accurate and selective determination of arginine in dietary supplements intended for the prevention and/or elimination of arginine deficiency.
В роботі розроблено аргінін-чутливий кондуктометричний біосенсор. Як кондуктометричний перетворювач використовували дві пари золотих гребінчастих електродів, нанесених на ситалову підкладинку. Для створення біоселективної мембрани використовували фермент аргініндeіміназу, яку іммобілізували шляхом ковалентного зшивання глутаровим альдегідом на чутливу поверхню однієї пари електродів кондуктометричного перетворювача, на другу пару електродів наносили референтну мембрану на основі бичачого сироваткового альбуміну. Визначено оптимальні умови іммобілізації ферменту. Вивчено вплив параметрів розчину (іонна сила, буферна ємність, рН та концентрація білкa) на роботу розробленого біосенсора. Досліджено стабільність функціонування та зберігання запропонованого біосенсора. Вивчено селективність біосенсора та його основні аналітичні характеристики (мінімальна границя визначення, лінійний та динамічний діапазон роботи біосенсора тощо). Показано, що розроблений біосенсор є перспективним для кількісного визначення вмісту аргініну в реальних зразках.