This work presents the development of an amperometric biosensor for detecting aspartate aminotransferase (AST) activity in biological fluids using a platinum disk electrode as the working transducer. Optimal concentrations of substrates (aspartate, α-ketoglutarate) and the coenzyme (pyridoxal phosphate) were determined to ensure efficient biosensor operation. A semi-permeable poly-m-phenylenediamine membrane was applied to enhance selectivity against electroactive interferents. The biosensor demonstrated good stability (storage, continuous operation, and production reproducibility) and analytical performance (sensitivity 8.56 nA/min for 50 U/L AST, LOD 1 U/L, linear range 1–110 U/L). Testing with real samples showed a high correlation (R = 0.989) with spectrophotometric analysis, supporting its potential for further applications.
5 April 2023 in Sensor Electronics and Microsystem Technologies
В роботі розроблено аргінін-чутливий кондуктометричний біосенсор. Як кондуктометричний перетворювач використовували дві пари золотих гребінчастих електродів, нанесених на ситалову підкладинку. Для створення біоселективної мембрани використовували фермент аргініндeіміназу, яку іммобілізували шляхом ковалентного зшивання глутаровим альдегідом на чутливу поверхню однієї пари електродів кондуктометричного перетворювача, на другу пару електродів наносили референтну мембрану на основі бичачого сироваткового альбуміну. Визначено оптимальні умови іммобілізації ферменту. Вивчено вплив параметрів розчину (іонна сила, буферна ємність, рН та концентрація білкa) на роботу розробленого біосенсора. Досліджено стабільність функціонування та зберігання запропонованого біосенсора. Вивчено селективність біосенсора та його основні аналітичні характеристики (мінімальна границя визначення, лінійний та динамічний діапазон роботи біосенсора тощо). Показано, що розроблений біосенсор є перспективним для кількісного визначення вмісту аргініну в реальних зразках.
30 September 2026 in Sensor Electronics and Microsystem Technologies
This paper presents the development and optimization of a biosensor for the accurate and rapid determination of L-lactate concentration in human serum samples. The biosensor uses lactate oxidase (LOx) immobilized in a bovine serum albumin matrix on a platinum transducer, modified with a semipermeable poly-meta-phenylenediamine (PPD) membrane. The PPD membrane minimizes influence from solution parameters like ionic strength and protein content, as well as interferents in blood serum on an analysis result. The biosensor offers a broad linear range (7–1000 μM), low detection limit (7 μM), and short analysis time (less than 10 min), making it suitable for real serum samples measurement. Results showed high correlation with reference methods, with a correlation coefficient of 0.982 in comparison with standard analysis method. Stability tests indicated an RSD of 1.5% and 5.4% for model and real samples analysis, with functionality sustained over 5 days with continuous use. This biosensor is promising for clinical diagnostics due to its speed, accuracy, and stability in measuring L-lactate.
28 March 2025 in Sensor Electronics and Microsystem Technologies
The work describes the development of a monoenzyme conductometric biosensor for the determination of arginine in pharmaceutical samples. The biosensor was created by immobilizing recombinant arginine deiminase (ADI) on electrodes using covalent cross linking in glutaraldehyde vapours. To achieve maximum sensitivity, the influence of the working buffer solution parameters, such as pH, buffer capacity, ionic strength, temperature, and protein concentration, on the operation of the biosensor was investigated. The analytical characteristics, signal reproducibility, and storage stability of the biosensor with the optimized buffer solution were studied. To test the biosensor, arginine in food additives was determined using the standard addition biosensor method. The work shows that the results correlate well with ion-exchange chromatography and enzymatic spectrophotometric analysis. The influence of different sample preparation options on the accuracy of arginine determination was also studied. The biosensor is effective for the accurate determination of arginine in dietary supplements intended to correct its deficiency.
In this study, the additional enzyme catalase is added to the bioselective membrane of the monoenzyme biosensor to improve the analytical characteristics of the biosensor. In this case, catalase is used to increase the saturate the biomembrane with oxygen, and, accordingly, facilitate the passage of the reaction catalyzed by enzymes of the oxidase class. A standard monoenzyme conductometric biosensor based on glucose oxidase for glucose determination and a new bi-enzyme biosensor based on glucose oxidase and catalase were compared. The optimal method of coimmobilization of enzymes on the surface of the conductometric transducer was investigated, as well as the dependence of the biosensor performance on the concentration of catalase in the bioselective membrane. The stability of the biosensor preparation procedure and the reproducibility of its results were verified. The analytical characteristics of the proposed bi-enzyme biosensor are compared with the monoenzyme biosensor. It is shown that the addition of catalase to the bioselective element of the biosensor as an additional enzyme significantly improves the analytical characteristics of the biosensor, including sensitivity, reproducibility of measurement results, and linear and dynamic ranges of operation. The developed method could be used in future to improve the parameters of other oxidase-based biosensors.