Representative Publications

View All Publications
13 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
KNKatarzyna Justyna Nowak-Dzieszko
Katarzyna Justyna Nowak-Dzieszko
Maciej MijakowskiMaciej Mijakowski
Maciej Mijakowski
JMJarosław Müller
Jarosław Müller
There are many different factors affecting indoor air quality: environmental ones such as temperature, humidity, human activities within the building, smoking, cooking, and cleaning, but also external pollutants such as particulate matter, biological contaminants, and viruses or allergens. This study investigated the indoor air quality (IAQ) of a primary-school classroom in Cracow, Poland, based only on CO2 concentration levels exhaled by occupants. In the 1960s, over a thousand schools were built in Poland using similar technology. Most of them are still in use, and in many cases, modernization works are being carried out to improve their building envelope and the comfort of their use. The analyzed school is one of several hundred similar ones in southern Poland. Therefore, analyzing the possibilities of improving IAQ is an important topic, and the results can be used in the modernization process for many other buildings. Measurements indicated that the CO2 levels significantly exceeded acceptable standards, signaling poor air quality during usage time. This problem was connected mainly with the low efficiency of the natural ventilation system being used in the classroom. It is worth emphasizing that this type of ventilation system is the most commonly used ventilation solution in Polish schools. To address this problem, the classroom environment was simulated using CONTAM software, and the model was validated by comparing the simulated measurement data against the collected measurement data. Next, simulations for the entire heating season in Cracow were conducted, revealing that the IAQ remained consistently poor throughout this period. These findings highlight the persistent problem of inadequate ventilation in the classroom, which can have adverse effects on the health and performance of students and teachers. This article shows the usefulness of CONTAM for modeling not only gravity ventilation but also the window-opening process. The validated CONTAM model will be subsequently utilized to simulate annual IAQ conditions under various ventilation strategies in order to identify the most effective methods for maintaining acceptable IAQ while minimizing energy consumption. In our future analysis, the validated model will be used to test the following systems: demand-controlled ventilation (DCV), exhaust ventilation, and DCV/balanced ventilation with heat recovery.

15 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
Blanca TejedorBlanca Tejedor
Blanca Tejedor
Eva BarreiraEva Barreira
Eva Barreira
VFVasco Peixoto de Freitas
Vasco Peixoto de Freitas
TKTomasz Kisilewicz
Tomasz Kisilewicz
KNKatarzyna Justyna Nowak-Dzieszko
Katarzyna Justyna Nowak-Dzieszko
Umberto BerardiUmberto Berardi
Umberto Berardi
Infrared thermography (IRT) has become a commonly applied non-destructive testing method for assessing building envelopes. Like any diagnosis tool, IRT requires an appropriate experience and principle understanding, mainly when the method is used for quantitative analyses. The challenges of the IRT often deal with the dynamic properties of building partitions. Climatic conditions have a certain variability, and the accumulated energy storage in the building components can affect their temperature as well as the calculated thermal performance. This paper aims to analyze how stationary and dynamic regimes of a quantitative IRT test could impact the measured thermal transmittance of heavy multi-leaf walls. Investigation in two European countries with different climatic conditions are reported. In this way, it is discussed which boundary conditions should be guaranteed to provide reliable information about a building envelope using quantitative IRT. In order to check the quality of the measurements, the heat flux meter (HFM) method was also implemented, following the ISO 9869. The research revealed that it could be possible to use short-lasting tests in the climatic conditions of Southern Europe, while long-term tests should be implemented in Northern European countries where climatic conditions are less regular.

18 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
TKTomasz Kisilewicz
Tomasz Kisilewicz
KNKatarzyna Justyna Nowak-Dzieszko
Katarzyna Justyna Nowak-Dzieszko
KNKatarzyna Nowak
Katarzyna Nowak
Sabina KucSabina Kuc
Sabina Kuc
KOKsenia Ostrowska
Ksenia Ostrowska
Piotr Mikołaj ŚliwińskiPiotr Mikołaj Śliwiński
Piotr Mikołaj Śliwiński
There are currently trends in the world to transfer and adapt traditional solutions to contemporary needs. This applies, inter alia, to mobile shelters used by nomadic peoples. The article is devoted to the research on the quality of internal air in the yurt and the possibilities of its adaptation to high contemporary quality and environmental requirements, while maintaining its characteristic sustainable values. The tested traditional Mongolian yurt was moved from the dry and cold climate of the Asian steppe to the temperate climate of Central Europe and has been significantly modified. The outer shell materials have been changed, replacing natural materials with modern tight insulating foils. The wood-fired stove has been replaced with an electric heater and the roof opening has been firmly closed. All of these modifications resulted in far-reaching changes in the quality of the internal environment in the yurt. The conducted measurements and simulations of CO2 concentration in the modified yurt proved that the efficiency of ventilation system is not sufficient and that the air quality is very poor (even for a single user). In the case of a larger number of users, the concentration of CO2 has already reached a level that was dangerous to health. The simplest method of improving the air quality in the yurt is its careful unsealing to the required level. Striving for a low energy demand, however, would require a completely different approach (for example, in the form of forced ventilation with a heat recovery unit, ultimately powered with a PV array). Such a solution is very different from the traditional yurt model but is close to modern expectations and environmental requirements.

30 June 2020 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
KNKatarzyna Justyna Nowak-Dzieszko
Katarzyna Justyna Nowak-Dzieszko
TKTomasz Kisilewicz
Tomasz Kisilewicz
The authors undertook research on the proper strategy of operation of educational building with gravitational ventilation in historic city center with high concentration of particulate matter PM10 and PM 2.5. In this facility the momentary increase in carbon dioxide concentration is often very high, and at the same time health requirements regarding atmospheric aerosol should be absolutely met. That is why long-term measurements of PM concentration outside and inside, as well as carbon dioxide concentration inside were carried out. CO2 was used also as a tracer gas for measurement of air change intensity. The article presents the first results of these tests and a correlation that occurs between the external and internal concentration of particulate matter PM 10 and PM 2.5. Due to a significant filtration effect of the external building envelope and particle deposition a potential conflict between required gravitational ventilation intensity and internal air pollution with particulate matters was partially reduced.

23 May 2026 in Energies
Verified
Journal Article
Open access
PDF file
KNKatarzyna Justyna Nowak-Dzieszko
Katarzyna Justyna Nowak-Dzieszko
Maciej MijakowskiMaciej Mijakowski
Maciej Mijakowski
JMJarosław Müller
Jarosław Müller
EKEwa Kozak-Jagieła
Ewa Kozak-Jagieła
PWPawel Wargocki
Pawel Wargocki
Poor indoor air quality (IAQ) in naturally ventilated school buildings remains a widespread problem, particularly during the heating season, when limited ventilation leads to elevated CO2 concentrations. At the same time, increasing ventilation rates may significantly increase energy demand, creating a conflict between IAQ and energy efficiency. This study aims to evaluate whether CO2-based demand-controlled mechanical ventilation, particularly with heat recovery (HRV), can improve IAQ while maintaining acceptable energy performance in existing school buildings. A previously validated CONTAM model of a Polish primary school classroom was used to simulate natural ventilation, mechanical exhaust ventilation, and balanced ventilation with heat recovery. In mechanical systems, CO2-based demand-controlled ventilation (DCV) was applied. The resulting airflow rates were then used in EnergyPlus simulations to assess seasonal heating and primary energy demand under Kraków climatic conditions. Increasing the outdoor air supply rate significantly reduced indoor CO2 concentration but led to higher heating demand in exhaust ventilation systems. In contrast, HRV reduced heating energy demand by more than 80% compared with exhaust ventilation while maintaining comparable indoor air quality. Although HRV required additional electricity for fan operation, the total primary energy consumption remained low. The results demonstrate that CO2-based DCV systems with heat recovery provide an effective balance between indoor air quality and energy performance. These findings support the application of HRV as a practical retrofit solution for improving ventilation in existing school buildings.

17 June 2025 in Archives of Civil Engineering
Verified
Journal Article
Open access
PDF file
KNKatarzyna Justyna Nowak-Dzieszko
Katarzyna Justyna Nowak-Dzieszko
JMJarosław Müller
Jarosław Müller
Children spend on average 7–10 hours per weekday at school, that’s why the indoor air quality in the classrooms plays a key role in the assessment of the effects of their personal exposure to the air quality. Many scientific articles indicate the substantial influence of carbon dioxide (CO2º levels and overall air quality within educational environments on the well-being and cognitive performance of children. This article presents the case study of the classroom in the primary school in Cracow with very unfavourable indoor air quality caused by the usage pattern. In the classroom, there is a natural ventilation system, still the most common in the Polish existing buildings. The very high level of CO2 exceeding the standard requirements connected with low ventilation efficiency effects in harmful indoor conditions. Based on the measurements conducted in the classroom during the lessons with the users in and taking into account formal requirements authors assessed the quality of indoor air. The main reason for those unfavourable conditions is an inefficient natural ventilation system. This paper is also supposed to answer the question of whether temporary opening windows can assure proper concentration of CO2 in a standard classroom and, if not, what would be the optimal ventilation rate. In the next step, this optimal minimum required ventilation rate for the classroom was calculated. It could be used as a design assumption in the selection of a ventilation system.