Aliya Zhumadirova

Mrs. Aliya Zhumadirova

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
DIDauren Dzhambulovich Issabekov
Dauren Dzhambulovich Issabekov
AKAleksandr Kislov
Aleksandr Kislov
VMVadim Pavlovich Markovskiy
Vadim Pavlovich Markovskiy
NZNurlybek Shakaevich Zhumataev
Nurlybek Shakaevich Zhumataev
AZAliya Zhumadirova
Aliya Zhumadirova
DNDamir Narynbayev
Damir Narynbayev
Construction of relay protections of electrical installations without the use of bulky metal- and insulation-intensive measuring current transformers (CTs) was repeatedly discussed at Conferences of the International Council on Large Electric Systems (CIGRE) as a challenge for the electric power industry. In the article, the authors present resource-saving reed switch current protection for 6–10-kV electrical installations connected to switchgear cells, which is an alternative to traditional protections. The scientific novelty of the work lies in (a) reed switch protection design on the basis of measuring the magnetic induction in different modes and at different points inside a cell, and we prove that inductance values are sufficient to detect phase short-circuits in electrical installations fed from this cell and derive the dependence of the induction on the position of an inductance coil inside the cell; (b) proven possibility of using the simplest formula of the Biot–Savart law for the calculations if the experimentally obtained coefficients are introduced into it; (c) development of a technique for calculating the parameters of the overcurrent protection based on reed switches. Experimental results are presented in graphical form and clearly show the points of EMS maxima and minima. Settings for resource-saving current protection are selected and a feasibility study of the effectiveness of resource-saving overcurrent protection is carried out. A technical and economical assessment of the efficiency of the suggested overcurrent protection is conducted.

14 July 2021
Verified
Conference Paper
Open access
PDF file
AZAliya Zhumadirova
Aliya Zhumadirova
VMVadim Markovskiy
Vadim Markovskiy
AKAleksandr Kislov
Aleksandr Kislov
The most common type of short circuit in a three-phase system is a single-phase-to-ground short circuit, accounting for 70 to 90% of electrical faults. In this paper simulation of the protective device from single-phase-to-ground short circuit with automatic change of current setting in electrical networks of 6-10 kV voltage on the basis of Coloured Petri Net is considered. The complexity of elaborated technical systems makes the problem of their modelling actual at the stage of development with the purpose of obtaining estimations of prospective and achievable characteristics. Now the modelling theory of the dynamic discrete systems, based on the formalism of Coloured Petri Nets has a wide application. Petri Net, describing the device operation, was designed and analysed using CPN Tools Programm. The resulting Petri net is correct, as it is live, reversible and safe. Thereby designed device can provide the selective protection from single-phase-to-ground short circuit.

14 July 2021
Verified
Conference Paper
Open access
PDF file
VGVladimir Govorun
Vladimir Govorun
OGOleg Govorun
Oleg Govorun
VMVadim Markovskiy
Vadim Markovskiy
AZAliya Zhumadirova
Aliya Zhumadirova
In this paper, on the basis of simulation modeling, an algorithm for studying the current resonance that occurs in the power supply system with a chaotic change of the load power and variation of reactive power compensation degree, in the presence of consumers with a nonlinear current-voltage characteristic is proposed. It is shown that overloading of capacitor banks can occur in a wide frequency range, close to the resonant frequency. The proposed algorithm determines all possible frequencies at which an increase of currents in capacitor banks can occur above the permissible values in parallel resonance. The purpose of the proposed work: to show in what operating modes of the enterprise power supply system an overload of capacitors by currents of higher harmonics can occur when the load power changes and the degree of reactive power compensation varies.

19 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
ABAlisher Baltin
Alisher Baltin
SISultanbek Sansyzbayevich Issenov
Sultanbek Sansyzbayevich Issenov
GNGulim Nurmaganbetova
Gulim Nurmaganbetova
AZAliya Zhumadirova
Aliya Zhumadirova
AYAssel Yussupova
Assel Yussupova
AMAliya D Maussymbayeva
Aliya D Maussymbayeva
This article presents research on the possibilities of using information and communication technologies in monitoring systems for electrical networks with isolated neutral, aimed at improving and automating production functions in the energy sector. This aligns with the digitalization policy of Kazakhstan’s economy and is part of similar programs in the field of the electric power industry. This article explores an approach to organizing a digital monitoring system for emergency conditions, specifically single-phase ground faults in medium-voltage lines within the range of 6–35 kV, including the new voltage class of 20 kV. A version of such a system is proposed, based on a combination of a server, a wireless information network, and remote digital voltage measurement nodes. This wireless information and communication network is designed to detect the locations of single-phase ground faults (SPGF) using specialized zero-sequence voltage sensors installed at various points along the power transmission lines, along with wireless signal transmission channels to the dispatcher’s server. To ensure protection against industrial interference, based on the results of practical environment modeling, a transmission technology most resistant to external noise is selected. This article proposes the selection of equipment necessary for implementing wireless transmission technology and develops two versions of a digital voltmeter design based on low-power programmable microcontrollers. The proposed technical solutions require further experimental validation, and therefore, the authors plan to conduct additional research and practical experiments in the future.

30 September 2024 in Bulletin of Toraighyrov University. Energetics series
Verified
Journal Article
Closed access
AZAliya Zhumadirova
Aliya Zhumadirova
В данной статье разработаны математическая модель и программное обеспечение устройства автоматического контроля состояния изоляции и тока однофазного замыкания на землю в сетях напряжением 6–10 кВ. Основой для разработки устройства служат существующие методы определения параметров изоляции и тока замыкания на землю в трехфазных электрических сетях с изолированной нейтралью напряжением выше 1000 В, обладающие существенной простотой измерений и расчета параметров изоляции и тока замыкания на землю по сравнению с другими косвенными методами. При проектировании математической модели любого цифрового устройства широко применяются методы теории автоматов и теории графов, позволяющие синтезировать достаточно сложные модели вычислительных устройств для определенных прикладных задач. На начальном этапе разработки математической модели составлена содержательная граф-схема алгоритма, в которой внутри условных и операторных вершин записаны логические условия и микрокоманды в содержательных терминах. На основе структурной схемы и систем уравнений выходных функций и функций переходов построена логическая схема FSM устройства контроля состояния изоляции и тока однофазного замыкания на землю, приведен программный код. Ключевые слова: электрическая сеть, изоляция, контроль, finite-state machine, программное обеспечение.

28 March 2025 in Bulletin of Toraighyrov University. Energetics series
Verified
Journal Article
Closed access
AZAliya Zhumadirova
Aliya Zhumadirova
В данной статье разработано программное обеспечение устройства централизованной защиты от однофазного замыкания на землю в электрических сетях промышленных предприятий. Основой для разработки устройства служит метод централизованной защиты линий от однофазного замыкания на землю (ОЗЗ) c автоматическим изменением уставки защиты по току ОЗЗ при изменении конфигурации распределительной электрической сети с изолированной нейтралью напряжением 6–10 кВ. Применение данного способа обеспечивает высокую селективность защиты от однофазного замыкания на землю, что способствует повышению надежности и уровня электробезопасности при эксплуатации электроустановок. При разработке алгоритма функционирования устройства применялась теория цветных сетей Петри. Теория цветных сетей Петри близка к структурным методам моделирования систем, она базируется на хорошо разработанном математическом аппарате и поэтому допускает проведение аналитических и имитационных исследований. При выборе элементной базы устройства наиболее целесообразно применение микропроцессоров, так как они обладают большими вычислительными и логическими возможностями при высокой надежности, универсальности применения, малых размерах и дешевизне. В частности, микроконтроллеры семейства AVR отличаются большой скоростью работы, большой универсальностью, быстродействием. В результате проведенного анализа был выбран микроконтроллер фирмы Atmel Corporation Atmega8535 как наиболее оптимальный для реализации устройства. Ключевые слова: электрическая сеть, однофазное замыкание, централизованная защита, микроконтроллер, программное обеспечение.