The main hindrance to the diffusion of proton therapy facilities is the high cost for gantry installations. An alternative technical option is provided by fixed-beam treatment rooms, where the patient is rotated and translated in space with a robotic arm solution to enable beam incidence from various angles. The technological efforts based on robotic applications made up to now for patient positioning in proton beam facilities are described here, highlighting their limitations and perspectives.
Breast cancer is the leading cause of cancer deaths worldwide in women. This aggressive tumor can be categorized into two main groups—in situ and infiltrative, with the latter being the most common malignant lesions. The current use of magnetic resonance imaging (MRI) was shown to provide the highest sensitivity in the detection and discrimination between benign vs. malignant lesions, when interpreted by expert radiologists. In this article, we present the prototype of a computer-aided detection/diagnosis (CAD) system that could provide valuable assistance to radiologists for discrimination between in situ and infiltrating tumors. The system consists of two main processing levels—(1) localization of possibly tumoral regions of interest (ROIs) through an iterative procedure based on intensity values (ROI Hunter), followed by a deep-feature extraction and classification method for false-positive rejection; and (2) characterization of the selected ROIs and discrimination between in situ and invasive tumor, consisting of Radiomics feature extraction and classification through a machine-learning algorithm. The CAD system was developed and evaluated using a DCE–MRI image database, containing at least one confirmed mass per image, as diagnosed by an expert radiologist. When evaluating the accuracy of the ROI Hunter procedure with respect to the radiologist-drawn boundaries, sensitivity to mass detection was found to be 75%. The AUC of the ROC curve for discrimination between in situ and infiltrative tumors was 0.70.
30 November 2010 in Strahlentherapie und Onkologie
The use of very high energy electron (VHEE) beams, with energies between 50 and 400 MeV, has drawn considerable interest in radiotherapy due to their deep tissue penetration, sharp beam edges, and low sensitivity to tissue density. VHEE beams can be precisely steered with magnetic components, positioning VHEE therapy as a cost-effective option between photon and proton therapies. However, the clinical implementation of VHEE therapy (VHEET) requires advances in several areas: developing compact, stable, and efficient accelerators; creating sophisticated treatment planning software; and establishing clinically validated protocols. In addition, the perspective of VHEE to access ultra-high dose–rate regime presents a promising avenue for the practical integration of FLASH radiotherapy of deep tumors and metastases with VHEET (FLASH-VHEET), enhancing normal tissue sparing while maintaining the inherent dosimetric advantages of VHEET. However, FLASH-VHEET systems require validation of time-dependent dose parameters, thus introducing additional technological challenges. Here, we discuss recent progress in VHEET research, focusing on both conventional and FLASH modalities, and covering key aspects including dosimetric properties, radioprotection, accelerator technology, beam focusing, radiobiological effects, and clinical outcomes. Furthermore, we comprehensively analyze initial VHEET in silico studies on coverage across various tumor sites.
Although patients experience radiation proctitis post radiotherapy no internationally tested instruments exist to measure these symptoms. This Phase IV study tested the scale structure, reliability and validity and cross-cultural applicability of the EORTC proctitis module (QLQ-PRT23) in patients who were receiving pelvic radiotherapy. Patients (n = 358) from six countries completed the EORTC QLQ-C30, QLQ-PRT23 and EORTC Quality of Life Group debriefing questions. Clinicians completed the EORTC Radiation Therapy Oncology Group scale. Questionnaires were completed at four time-points. The module’s scale structure was examined and validated using standard psychometric analysis techniques. Three items were dropped from the module (QLQ-PRT23 → QLQ-PRT20). Factor analysis identified five factors in the module: bowel control; bloating and gas; emotional function/lifestyle; pain; and leakage. Inter-item correlations were within r = 0.3–0.7. Test-Retest reliability was high. All multi-item scales discriminated between patients showing symptoms and those without symptomology. The module discriminated symptoms from the clinician completed scoring and for age, gender and comorbidities. The EORTC QLQ-PRT20 is designed to be used in addition to the EORTC QLQ-C30 to measure quality of life in patients who receive pelvic radiotherapy. The EORTC QLQ-PRT20 is quick to complete, acceptable to patients, has good content validity and high reliability. Australian and New Zealand Clinical Trials Registry (ANZCTR) ACTRN12609000972224 .