Joëll Magré

Mr. Joëll Magré

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
KWKoen Willemsen
Koen Willemsen
JMJoëll Magré
Joëll Magré
Jeroen MolJeroen Mol
Jeroen Mol
HNHerke Jan Noordmans
Herke Jan Noordmans
Harrie WeinansHarrie Weinans
Harrie Weinans
MKMoyo C. Kruyt
Moyo C. Kruyt
For decades, the advantages of rapid prototyping for clinical use have been recognized. However, demonstrations of potential solutions to treat spinal problems that cannot be solved otherwise are scarce. In this paper, we describe the development, regulatory process, and clinical application of two types of patient specific 3D-printed devices that were developed at an in-house 3D point-of-care facility. This 3D lab made it possible to elegantly treat patients with spinal problems that could not have been treated in a conventional manner. The first device, applied in three patients, is a printed nylon drill guide, with such accuracy that it can be used for insertion of cervical pedicle screws in very young children, which has been applied even in semi-acute settings. The other is a 3D-printed titanium spinal column prosthesis that was used to treat progressive and severe deformities due to lysis of the anterior column in three patients. The unique opportunity to control size, shape, and material characteristics allowed a relatively easy solution for these patients, who were developing paraplegia. In this paper, we discuss the pathway toward the design and final application, including technical file creation for dossier building and challenges within a point-of-care lab.

8 August 2023 in Spine
Verified
Journal Article
Open access
AMAaron J.B.W.D. Moens
Aaron J.B.W.D. Moens
JMJoëll Magré
Joëll Magré
MKMoyo C. Kruyt
Moyo C. Kruyt
René M. CasteleinRené M. Castelein
René M. Castelein
SRSteven de Reuver
Steven de Reuver
Study Design.: Cross-sectional. Objective.: The aim of this study was to describe morphologic changes of the annulus fibrosus (AF) and nucleus pulposus (NP) in children during growth using magnetic resonance imaging. Summary of Background Data.: Little is known of intervertebral disk (IVD) maturation as opposed to degeneration, such as changes in relative AF/NP proportions and orientation during growth. Studies suggest that IVD plays a role in the etiology of pediatric spinal deformities. Therefore, understanding the morphologic development of the AF and NP during growth is key. Materials and Methods.: An existing database of children aged 0 to 18 that had magnetic resonance imaging for indications unrelated to the spine were analyzed. The AF/NP were segmented semiautomatically from T1 to L5. The parameters: mean IVD height, cross-sectional area, slenderness (height/width ratio), volume (ratio), and relative position of the centroid of the NP within the IVD in three directions (x, y, z) were extracted, and compared between age, sex, and spinal level. Results.: IVD height increased modestly and predominantly in the low-thoracic and lumbar spine during the first 5 to 10 years of life. Cross-sectional area and thus volume increased steadily at all levels throughout growth. IVD slenderness decreased sharply in the first years of life and remains relatively stable throughout the remainder of growth. IVDs were smaller and more slender in females, especially in the mid-thoracic spine at early adolescence. In the upper-thoracic and mid-thoracic spine the NP comprises 10% to 12% of total IVD volume during growth, this percentage increases in the low-thoracic and lumbar spine towards 20% to 25%. In the anterior-posterior direction, the position of the nucleus increasingly shifts with age, possibly in line with the developing sagittal profile of the spine. Conclusion.: This study describes the development of thoracic and lumbar IVDs during growth and may be used as a reference for future studies on the role of IVD in the etiology of disk-related disorders.

9 June 2023 in 3D Printing in Medicine
Verified
Journal Article
Open access
PDF file
JMJoëll Magré
Joëll Magré
KWK. Willemsen
K. Willemsen
HKH. M. A. Kolken
H. M. A. Kolken
AZA. A. Zadpoor
A. A. Zadpoor
HVH. C. Vogely
H. C. Vogely
HWH. Weinans
H. Weinans
Custom-made triflange acetabular implants are increasingly used in complex revision surgery where supporting bone stock is diminished. In most cases these triflange cups induce stress-shielding. A new concept for the triflange is introduced that uses deformable porous titanium to redirect forces from the acetabular rim to the bone stock behind the implant and thereby reduces further stress-shielding. This concept is tested for deformability and primary stability.Three different designs of highly porous titanium cylinders were tested under compression to determine their mechanical properties. The most promising design was used to design five acetabular implants either by incorporating a deformable layer at the back of the implant or by adding a separate generic deformable mesh behind the implant. All implants were inserted into sawbones with acetabular defects followed by a cyclic compression test of 1800N for 1000 cycles.The design with a cell size of 4 mm and 0.2 mm strut thickness performed the best and was applied for the design of the acetabular implants. An immediate primary fixation was realized in all three implants with an incorporated deformable layer. One of the two implants with a separate deformable mesh needed fixation with screws. Cyclic tests revealed an average additional implant subsidence of 0.25 mm that occurred in the first 1000 cycles with minimal further subsidence thereafter.It is possible to realize primary implant fixation and stability in simulated large acetabular revision surgery using a deformable titanium layer behind the cup. Additional research is needed for further implementation of such implants in the clinic.

17 August 2024 in Animals
Verified
Journal Article
Open access
PDF file
IKIrin Kwananocha
Irin Kwananocha
JMJoëll Magré
Joëll Magré
AKAmir Kamali
Amir Kamali
FVFemke Verseijden
Femke Verseijden
KWKoen Willemsen
Koen Willemsen
BMBjörn Meij
Björn Meij
The acetabular rim extension (ACE-X) implant is a custom-made three-dimensionally printed titanium device designed for the treatment of canine hip dysplasia. In this study, 34 dogs (61 hips) underwent ACE-X implantation, and assessments were conducted using computed tomography, force plate analysis, Ortolani’s test, and the Helsinki chronic pain index (HCPI) questionnaires at five intervals: the pre-operative day, the surgery day, and the 1.5-month, 3-month, and 12-month follow-ups. Statistically significant increases in femoral head coverage with a negative Ortolani subluxation test were observed immediately after surgery and persisted throughout the study. Osteoarthritis (OA) scores remained stable, but osteophyte size significantly increased between the surgery day and the 12-month follow-up, especially in hips with a baseline OA score of 2 compared to those with a score of 1. The force plate data showed no significant changes during the study. The HCPI demonstrated a significant decrease in pain score from pre-operative value to six-week follow-up and gradually decreased over time. Major complications were identified in six hips (9.8%) of four dogs. In conclusion, the ACE-X implant effectively increased femoral head coverage, eliminated subluxation, and provided long-term pain relief with minimal complications, benefiting over 90% of the study population. The study supports the ACE-X implant as a valuable alternative treatment for canine hip dysplasia.

13 September 2024 in Acta Orthopaedica
Verified
Journal Article
Open access
PDF file
MHMilou F T Hüsken
Milou F T Hüsken
JMJoëll Magré
Joëll Magré
KWKoen Willemsen
Koen Willemsen
LSLiza N Van Steenbergen
Liza N Van Steenbergen
MVMirthe H W Van Veghel
Mirthe H W Van Veghel
BWBart C H Van der Wal
Bart C H Van der Wal
Background and purpose: Hip dysplasia can present challenges for total hip arthroplasty (THA) due to anatomic abnormalities. We aimed to assess the association of age, sex, osteotomies prior to THA, and fixation method on 5- and 10-year revision-free implant survival and patient-reported outcome measures (PROMs) of THAs in patients with hip dysplasia.Methods: Using Dutch Arthroplasty Register data, we studied hip dysplasia patients receiving primary THAs in 2007–2021 (n = 7,465). THAs were categorized by age, pelvic osteotomy prior to THA (yes/no), and fixation (cemented, uncemented, hybrid, reverse hybrid). Kaplan–Meier and multivariable Cox models were used to determine 5- and 10-year revision-free implant survival and adjusted hazard ratios including 95% confidence intervals (CIs). Reasons for revision and PROMs were compared within the categories.Results: We found a 10-year revision-free implant survival of 94.9% (CI 94.3–95.5). Patients younger than 50 years had a 10-year implant survival of 93.3% (CI 91.9–94.7), Patients with prior pelvic osteotomy had a 10-year implant survival of 92.0% (CI 89.8–94.2). Fixation method and sex were not associated with implant survival. Patients with a prior pelvic osteotomy had more revisions due to cup loosening and reported lower PROM scores than patients without earlier osteotomy.Conclusion: 5- and 10-year revision-free implant survival rates of THA for hip dysplasia are 96.4% and 94.9%. Age and prior osteotomies were associated with decreased implant survival rates in patients with hip dysplasia, while fixation method was not. Prior osteotomies were also associated with reduced PROM scores.

2 October 2025 in European Spine Journal
Verified
Journal Article
Open access
PDF file
JCJules Cool
Jules Cool
PLPeter Lafranca
Peter Lafranca
JMJoëll Magré
Joëll Magré
JDJohannes GG Dobbe
Johannes GG Dobbe
MKMoyo C. Kruyt
Moyo C. Kruyt
BRBarend J. van Royen
Barend J. van Royen
Purpose: 3D-printed patient-specific guides enable accurate pedicle screw placement in the treatment of paediatric spinal deformities. MRI-based synthetic CT (sCT) eliminates the radiation exposure associated with the preoperative planning CT, while still providing detailed bony morphology. It may therefore offer a radiation-free method for pedicle screw navigation. Thus, the aim of this study was to compare the accuracy of thoracic and lumbar pedicle screw placement using 3D-printed guides based on conventional CT versus sCT. Methods: Full-spine MRI and CT images of four human cadaveric spines were obtained, followed by AI-generation of sCTs, the digital planning of pedicle screws and 3D-printed guide manufacturing. A total of 62 K-wires were inserted, 30 sCT-based and 32 CT-based. Accuracy was evaluated by superimpose analysis of planned and achieved trajectories, and by the postoperative grading of the cortical breach rate using the Gertzbein-Robbins classification, based on projected screws along the K-wires. Results: Median translational entry-point deviations were 1.0 mm vertically and 0.5 mm horizontally for both sCT-based guides and CT-based guides. Angular deviations in the axial plane were 1.0˚ for sCT and 0.9˚ for CT. In the sagittal plane these were 1.8˚ and 2.1˚, respectively. No significant differences were observed between sCT and CT. Grading of pedicle’s cortical breach showed no severe malposition for both sCT- and CT-based guides. Conclusion: sCT matched the accuracy of conventional CT in providing source data for personalized 3D-printed guides for thoracic and lumbar pedicle screw placement in terms of translational- and angular deviations, and cortical breach rates in this cadaveric study.