Hydraulic turbines constitute an essential component within the hydroelectric power generation industry, contributing to renewable energy production with minimal environmental pollution. Maintaining stable turbine operation presents a considerable challenge, which necessitates effective fault diagnosis and warning systems. Timely and efficient fault w arnings are particularly vital, as they enable personnel to address emerging issues promptly. Although backpropagation (BP) networks are frequently employed in fault warning systems, they exhibit several limitations, such as susceptibility to local optima. To mitigate this issue, this paper introduces an improved social engineering optimizer (ISEO) method aimed at optimizing BP networks for developing a hydraulic turbine warning system. Experimental results reveal that the ISEO-BP-based approach offers a highly effective fault warning system, as evidenced by superior performance metrics when compared to alternative methods.
The gas relay is a common non-electric protection device inside transformers, installed on the connecting pipeline between the transformer oil tank and the oil conservator. When the transformer malfunctions and the oil flow value reaches the heavy gas setting value of the gas relay, a heavy gas alarm is triggered. Therefore, accurately analyzing the heavy gas action characteristics and the setting value of the gas relay directly affects the accuracy of the heavy gas alarm. The BF(Bi-Float) type double float ball gas relay uses steady-state oil flow to calibrate the setting values of heavy gas action. In reality, transformer faults cause transient oil flow. To explore the relationship between the oil flow state and gas relay flow velocity setting values, a dynamic model of the heavy gas action process of BF type double float ball gas relay was first established, and the influence of the oil flow state on the gas relay baffle action process was analyzed. Then, a transient oil flow impact test bench was developed to experimentally study the heavy gas action characteristics of gas relays under different intensities of transient oil flow impact. Theoretical and experimental research results indicate that different oil flow impact states have a significant effect on the flow velocity setting values of gas relays. The flow velocity setting value of the BF type double float ball gas relay used in this study under transient oil flow impact is 0.8 m/s, which is lower than its factory flow velocity setting value of 1 m/s. These research results have positive significance for optimizing the performance of gas relays and improving the operational reliability of power transformers.
This study proposes a novel method for estimating the axial velocity of unmanned aerial vehicles (UAVs) using motion blur images captured in environments where GPS signals are unavailable and lighting conditions are poor, such as underground tunnels and corridors. By correlating the length of motion blur observed in images with the UAV’s axial speed, the method addresses the limitations of traditional techniques in these challenging scenarios. We enhanced the accuracy by synthesizing motion blur images from neighboring frames, which is particularly effective at low speeds where single-frame blur is minimal. Six flight experiments conducted in the corridor of a hydropower station demonstrated the effectiveness of our approach, achieving a mean velocity error of 0.065 m/s compared to ultra-wideband (UWB) measurements and a root-mean-squared error within 0.3 m/s. The results highlight the stability and precision of the proposed velocity estimation algorithm in confined and low-light environments.
In the accurate calculation of the temperature rise and hot spots of transformer windings, considering the inter-turn insulation will lead to a sharp increase in the workload of detailed modeling and a large number of mesh refinements. To address this issue, this paper proposes a calculation method for the equivalent thermal conductivity based on the minimum thermal resistance principle. This method can accurately calculate the equivalent thermal conductivities in the axial and radial directions of the windings. By using the disk windings model under the equivalent thermal conductivity, a temperature field analysis is performed on the actual windings with inter-turn insulation. To validate the method, models considering inter-turn insulation and equivalent models are constructed, and detailed analyses are performed using the empirical formula method and the equivalent method based on the minimum thermal resistance principle, respectively. By comparing the simulation results of the equivalent model and the model considering inter-turn insulation, it is found that the equivalent method based on the minimum thermal resistance principle not only significantly reduces the number of mesh elements but also achieves significantly improved accuracy in the temperature field analysis of the turn-divided model compared to the empirical formula method. Moreover, the winding temperature rise and hot spot positions before and after the equivalence are nearly identical and closer to the experimental results, demonstrating the validity of this method.
Accurate assessment of winding condition for power transformers is critical for ensuring the stable operation of modern power systems. Vibration signal has been regarded as an effective and promising evaluator for winding diagnosis. While on-line vibration monitoring offers the continuous, non-invasive and in-service assessment for winding condition, establishing precise correlations between the variable vibration patterns and specific winding condition remains challenging. To this end, an off-line vibration response analysis (VRA) technique was presented in the paper. Specifically, vibration frequency response (VFR) curves, indicating the winding response, were first obtained when the transformer was excited by the developed vibration response testing system, consisting of constant current variable-frequency power supply, intermediate transformer, accelerometers, data acquisition, control and analysis system. The VFR curves were then quantitatively and comprehensively described through four kinds of correlation indices. Finally, hierarchical integration strategy was proposed to aggregate those indices into quantitative criterion for condition assessment. The proposed method was validated on a real transformer under both normal and fault conditions, demonstrating superior performance. Notably, a 10% decrease in the evaluation criterion indicates an incipient winding looseness, while a reduction of 25% or more suggests severe looseness, prompting timely maintenance recommendations.
To provide a theoretical basis for sound barrier technology for fish, the effects of sound intensity and frequency on negative phonotaxis in adult bighead carp, Hypophthalmichthys nobilis, (weight 1.42–2.20 kg, body length 45.1–54.8 cm) were tested using underwater sound equipment in a pool with sound absorbing material to reduce sound reflection. There were two primary findings: (1) The cumulative times that fish remained in the high, medium and low sound intensity areas were significantly different (p < 0.001). The cumulative time decreased as sound intensity increased, demonstrating negative phonotaxis by the test fish towards high sound intensity. The cumulative time that fish remained in the high sound intensity area was less than in the control area and the difference was highly significant (p < 0.001). This strongly negative phonotaxic response can be exploited in developing sound barriers for guiding fish. Negative phonotaxis could be used to guide fish away from hazards and along migration routes, to help prevent exotic fish invasion, and to improve spawning success by preventing migration into tributaries where habitat has been severely impacted by dams or other human activities. (2) Adult H. nobilis respond differently to different frequencies of single-frequency sound. Higher-frequency sound (300–1000 Hz) produced a stronger negative phonotaxic response than lower-frequency sound (50–200 Hz), and the difference in cumulative times was highly significant (p < 0.001). Thus, high-frequency sound is more effective than low-frequency sound for producing negative phonotaxis. This research demonstrates that negative phonotaxis is affected by sound intensity and frequency. However, for a given application and target species, additional research should be carried out to determine the most effective combination of acoustic parameters.