Małgorzata Zaborniak

Dr. Małgorzata Zaborniak

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2025 in Materials
Verified
Journal Article
Open access
PDF file
BZBarbara Zbyrad
Barbara Zbyrad
Małgorzata ZaborniakMałgorzata Zaborniak
Małgorzata Zaborniak
ŁKŁukasz Wojciech Kochmański
Łukasz Wojciech Kochmański
KJKatarzyna Jasik
Katarzyna Jasik
Janusz KluczynskiJanusz Kluczynski
Janusz Kluczynski
Paweł TurekPaweł Turek
Paweł Turek
The continuous advancement of medical technologies and the increasing demand for high-performance medical devices have driven the search for innovative solutions in biomaterials engineering. However, ensuring the sterility of polymeric biomaterials while maintaining their mechanical integrity remains a significant challenge. This research examines how steam sterilization impacts the mechanical properties of four polymeric biomaterials frequently utilized in medical applications: MED610, PEEK, PET-G HT100, and RGD720. Samples were produced using additive manufacturing (AM), specifically Material Jetting (MJT) and Material Extrusion (MEX) processes, and exposed to steam sterilization at 121 °C and 134 °C. A comprehensive verification process was conducted to ensure the effectiveness of sterilization, including pre-sterilization cleaning, disinfection procedures, and the use of process indicators such as the Bowie–Dick test. Mechanical evaluation included bending tests and Rockwell hardness measurements to assess changes in structural integrity and mechanical strength after sterilization. The results revealed that, while some materials exhibited significant alterations in mechanical properties, others demonstrated high resistance to thermal and humidity exposure during sterilization. These findings provide critical insights into the selection and optimization of polymeric biomaterials for sterilizable medical applications, ensuring their durability and safety in clinical use.

23 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Małgorzata ZaborniakMałgorzata Zaborniak
Małgorzata Zaborniak
MBMichał Bremek
Michał Bremek
Grzegorz BudzikGrzegorz Budzik
Grzegorz Budzik
Janusz KluczynskiJanusz Kluczynski
Janusz Kluczynski
To achieve high precision and repeatability of prototyped models, work is carried out to improve existing solutions and thus expand the areas of application of 3D printers. Ways to increase the efficiency of 3D printing are being sought. The subject of the work concerns the analysis of dimensional and shape accuracy and repeatability of samples produced by a technology based on layered extrusion of thermoplastic polymers using FFF—fused filament fabrication technology. The key parameter for assessing the quality of parts is the property most expected by 3D printer users regarding the accuracy of dimensions of manufactured prototypes. As part of the research, conclusions were drawn regarding the precision of the samples as original patterns. The dimensional accuracy in the x, y, and z axes of the 3D printer was determined in terms of the design of the 3D printer’s actuator system. Three-dimensional maps of deviations of the pattern surface were used in relation to the nominal 3D CAD model to test the accuracy. The analytical results obtained during the research work, together with the graphs of the normal distribution probability function, indicate a high repeatability for each of the axes, and the highest repeatability was for the z-axis. The dimensions in the remaining axes were within the assumed tolerance of 0.1 mm, except for the two extreme dimensions, which were caused by a different method of heat dissipation, proving the influence of the arrangement of samples on the working platform.

22 August 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Paweł TurekPaweł Turek
Paweł Turek
Małgorzata ZaborniakMałgorzata Zaborniak
Małgorzata Zaborniak
KGKatarzyna Grzywacz-Danielewicz
Katarzyna Grzywacz-Danielewicz
MBMichał Bałuszyński
Michał Bałuszyński
BLBogumił Lewandowski
Bogumił Lewandowski
NDNatalia Daniel
Natalia Daniel
Background: Mandibular defects caused by trauma or tumor resection pose significant challenges in both functional and aesthetic reconstruction. Additive manufacturing (AM) technologies offer promising solutions for surgical planning and personalized treatment. Objectives: This review aims to evaluate current trends in the application of AM technologies for mandibular resection and reconstruction, with a particular focus on material selection, clinical integration, and technology-specific advantages. Methods: A structured literature review was performed using PubMed, Scopus, Web of Science, and Google Scholar. Studies published between January 2020 and May 2025 were screened using the following inclusion criteria: original peer-reviewed English-language research involving AM in mandibular surgery. The exclusion criteria included review articles, non-English sources, and non-mandibular studies. A total of 77 studies met the inclusion criteria and were analyzed in this review. Results: Based on the literature review conducted from 2020 to 2025, the most common restorative methods for the mandible using additively manufactured models include reconstruction with a titanium surgical plate bent to the curvature of the edges and angle of the mandible or a personalized titanium or PEEK surgical plate made directly based on the patient’s diagnosis. Implants made of Ti-6AL-4V ELI and bioceramic scaffolds are also used in the reconstruction process. They are developed based on patient diagnostic data and effectively replace the loss of mandibular bone structure. In addition, based on models and surgical guides created using additive manufacturing techniques, the performance of autogenous grafts from the fibula or iliac crest has improved significantly when used with a titanium implant plate. Conclusions: Additive manufacturing supports highly personalized and accurate mandibular reconstruction. The advantages of these methods include a reduced overall duration of procedures, a lower health risk for patients due to less reliance on general anesthesia, a near perfect match between the implant and the remaining hard tissues, and satisfactory aesthetic outcomes. However, success depends on the appropriate selection AM technology and material, particularly in load-bearing applications.

24 October 2022 in Polimery
Verified
Journal Article
Open access
PDF file
Grzegorz BudzikGrzegorz Budzik
Grzegorz Budzik
Małgorzata ZaborniakMałgorzata Zaborniak
Małgorzata Zaborniak
JRJakub Roczniak
Jakub Roczniak
The methodology and measurement results of the machine part produced directly from the 3D-CAD numerical model are presented. Representative additive techniques based on polymer processing were used. The accuracy of replication of CAD numerical models was assessed in terms of both external surface analysis and part volume.

25 November 2024 in Materials
Verified
Journal Article
Open access
PDF file
Małgorzata ZaborniakMałgorzata Zaborniak
Małgorzata Zaborniak
Janusz KluczynskiJanusz Kluczynski
Janusz Kluczynski
JSJakub Stańko
Jakub Stańko
Tomasz ŚlęzakTomasz Ślęzak
Tomasz Ślęzak
Polymeric materials are widely used in medical engineering, and with the dynamic development of additive manufacturing (AM) technology, increasing attention is being paid to research on the mechanical strength of composite polymer structures. At the same time, the impact of sterilization on, for example, surgical templates and the influence of the sterilization process on the geometry of these parts have not been sufficiently studied. In this work, the effect of steam sterilization on samples made of polymer materials for medical applications was presented. This research was carried out on samples with normative geometry made of polyetheretherketone (PEEK) polymers produced using the Material Extrusion (MEX) AM process and acrylic formulation (MED610) produced by Jetting Modeling Technology (JMT). These materials provide biocompatibility, which makes them suitable for potential medical applications. Steam sterilization was performed in an autoclave at temperatures of 121 °C and 134 °C. The three-point bending strength properties were determined according to ISO 178 standards. An INSTRON 5967 strength testing machine was used for those tests. Surface roughness analysis (according to ISO 21920) was performed and presented in 2D and 3D surface views using the Mountains Map Software (version 6.0).

16 May 2024 in Tehnički glasnik
Verified
Journal Article
Open access
PDF file
TDTomasz Dziubek
Tomasz Dziubek
MGMałgorzata Gontarz
Małgorzata Gontarz
BSBartłomiej Sobolewski
Bartłomiej Sobolewski
Małgorzata ZaborniakMałgorzata Zaborniak
Małgorzata Zaborniak
Grzegorz BudzikGrzegorz Budzik
Grzegorz Budzik
Broadly, understood additive manufacturing techniques expand the spectrum of production of machine parts that are used in various types of devices. However, the requirements to ensure dimensional and shape accuracy require the determination of approp...