Yasser H Hadi

Mr. Yasser H Hadi

Discipline of Medical Imaging, University College Cork, Cork, Ireland
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MAMohammad Alfelali
Mohammad Alfelali
EHElizabeth A. Haworth
Elizabeth A. Haworth
Osamah BarasheedOsamah Barasheed
Osamah Barasheed
ABAl-Mamoon Badahdah
Al-Mamoon Badahdah
HBHamid Bokhary
Hamid Bokhary
Yasser H HadiYasser H Hadi
Yasser H Hadi
In this large-scale cluster-randomized controlled trial (cRCT) we sought to assess the effectiveness of facemasks against viral respiratory infections. Over three consecutive Hajj seasons (2013, 2014, 2015) pilgrims’ tents in Makkah were allocated to ‘facemask’ or ‘no facemask’ group. Fifty facemasks were offered to participants in intervention tents, to be worn over four days, and none were offered to participants in control tents. All participants recorded facemask use and respiratory symptoms in health diaries. Nasal swabs were collected from the symptomatic for virus detection by reverse transcription polymerase chain reaction. Clinical symptoms and laboratory results were analyzed by ‘intention- to-treat’ and ‘per-protocol’. A total of 7687 adult participants from 318 tents were randomized: 3864 from 149 tents to the intervention group, and 3823 from 169 tents to the control group. Participants were aged 18 to 95 (median 34, mean 37) years, with a male to female ratio of 1:1.2. Overall, respiratory viruses were detected in 277 of 650 (43%) nasal/pharyngeal swabs collected from symptomatic pilgrims. Common viruses were rhinovirus (35.1%), influenza (4.5%) and parainfluenza (1.7%). In the intervention arm, respectively 954 (24.7%) and 1842 (47.7%) participants used facemasks daily and intermittently, while in the control arm, respectively 546 (14.3%) and 1334 (34.9%) used facemasks daily and intermittently. By intention-to-treat analysis, facemask use did not seem to be effective against laboratory-confirmed viral respiratory infections (odds ratio [OR], 1.4; 95% confidence interval [CI], 0.9 to 2.1, p = 0.18) nor against clinical respiratory infection (OR, 1.1; 95% CI, 0.9 to 1.4, p = 0.40). Similarly, in a per-protocol analysis, facemask use did not seem to be effective against laboratory-confirmed viral respiratory infections (OR 1.2, 95% CI 0.9–1.7, p = 0.26) nor against clinical respiratory infection (OR 1.3, 95% CI 1.0–1.8, p = 0.06). This trial was unable to provide conclusive evidence on facemask efficacy against viral respiratory infections most likely due to poor adherence to protocol.

7 May 2025 in Radiography
Verified
Journal Article
Open access
MBM. Bani-Ahmad
M. Bani-Ahmad
AEAndrew England
Andrew England
LML. McLaughlin
L. McLaughlin
Yasser H HadiYasser H Hadi
Yasser H Hadi
MMMark F McEntee
Mark F McEntee
Artificial intelligence (AI) is now transforming medical imaging, with extensive ramifications for nearly every aspect of diagnostic imaging, including computed tomography (CT). This current work aims to review, evaluate, and summarise the role of AI in radiation dose optimisation across three fundamental domains in CT: patient positioning, scan range determination, and image reconstruction. A comprehensive scoping review of the literature was performed. Electronic databases including Scopus, Ovid, EBSCOhost and PubMed were searched between January 2018 and December 2024. Relevant articles were identified from their titles had their abstracts evaluated, and those deemed relevant had their full text reviewed. Extracted data from selected studies included the application of AI, radiation dose, anatomical part, and any relevant evaluation metrics based on the CT parameter in which AI is applied. 90 articles met the selection criteria. Included studies evaluated the performance of AI for dose optimisation through patient positioning, scan range determination, and reconstruction across various CT scans, including the abdomen, chest, head, neck, and pelvis, as well as CT angiography. A concise overview of the present state of AI in these three domains, emphasising benefits, limitations, and impact on the transformation of dose reduction in CT scanning, is provided. AI methods can help minimise positioning offsets and over-scanning caused by manual errors and helped to overcome the limitation associated with low-dose CT settings through deep learning image reconstruction algorithms. Further clinical integration of AI will continue to allow for improvements in optimising CT scan protocols and radiation dose. This review underscores the significance of AI in optimizing radiation doses in CT imaging, focusing on three key areas: patient positioning, scan range determination, and image reconstruction.

24 January 2026 in European Journal of Radiology Artificial Intelligence
Verified
Journal Article
Open access
Yasser H HadiYasser H Hadi
Yasser H Hadi
AHAishah M. Hakami
Aishah M. Hakami
AAAmal M. Ajeebi
Amal M. Ajeebi
AFAreej M. Faqihi
Areej M. Faqihi
ESEyad T. Sendi
Eyad T. Sendi
AAAbdulrahman I. Abu Aqil
Abdulrahman I. Abu Aqil

1 April 2021 in Saudi Critical Care Journal
Verified
Journal Article
Closed access
PDF file
AKAmal A. Al Khalfan
Amal A. Al Khalfan
AGAhmed A. Al Ghamdi
Ahmed A. Al Ghamdi
SSStephanie De Simone
Stephanie De Simone
Yasser H HadiYasser H Hadi
Yasser H Hadi
Patients with critical illness and high mortality risk are frequently admitted to intensive care units (ICUs). Therefore, improving the quality of healthcare for these patients is essential. Improving overall health and following best practices for patient safety are important goals in the health-care sector; especially in critically ill patients. To achieve these goals, many researches have been conducted to develop procedures, protocols and improve ICU structure and design. To discuss the effectiveness of multidisciplinary team (MDT) implementation in ICUs in the Saudi Arabian hospitals and how would this approach significantly reduce ICU mortality rates and improves the quality of healthcare. This review search of electronic search engines was conducted, including ProQuest, Medline, and Google Scholar. The search was narrowed to a total of 21 articles between 2010 and 2020 articles were included, which were found to match the inclusion criteria. Findings indicated a positive effect of the MDT care on decreasing the ICU's mortality rates. The studies reviewed have documented the necessity of successful MDT care implementation for improved survival rates. A collaborative approach by the various health-care providers-nurses, physicians, intensivists, respiratory therapists, and pharmacists–enhances patient care, improves clinical outcomes, and reduces the mortality rate.

21 November 2024 in European Radiology
Verified
Journal Article
Closed access
PDF file
Yasser H HadiYasser H Hadi
Yasser H Hadi
LKLauren Keaney
Lauren Keaney
AEAndrew England
Andrew England
NMNiamh Moore
Niamh Moore
MMMark McEntee
Mark McEntee

15 July 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
AAAli B Alhailiy
Ali B Alhailiy
EAEssam Mohammed Alkhaybari
Essam Mohammed Alkhaybari
MAMohammed S Alshuhri
Mohammed S Alshuhri
AAAbdullah Yousef Al-Othman
Abdullah Yousef Al-Othman
THTarek Hegazi
Tarek Hegazi
MMMustafa Z. Mahmoud
Mustafa Z. Mahmoud
Objectives: Diagnostic reference levels (DRLs) are crucial tools for optimizing radiation exposure during different radiological examinations. This study aimed to establish preliminary DRLs for commonly performed computed tomographic angiography (CTA) examinations in Saudi Arabia. Methods: Data for three types of CTA examinations (cerebral, pulmonary, and lower-extremity) were collected from six medical cities across Saudi Arabia. Data sets related to 723 CTAs with a mean patient weight of 75 kg were analysed in detail. The DRL values were determined based on the 75th, median, and 25th CT dose index volume (CTDIvol) and dose length product (DLP) values. Results: The established DRLs were 1221 mGy cm for cerebral CTAs, 475 mGy cm for pulmonary CTAs, and 1040 mGy cm for lower-extremity CTAs. These values were comparable to those reported in other studies. Conclusions: This study provides preliminary DRLs for three common CTA procedures in Saudi Arabia. The widespread implementation of a low kVp and a high level of image reconstruction (IR) presents an opportunity for further dose reduction. These findings can serve as a foundation for future nationwide DRL surveys and the optimization of CTA imaging protocols in Saudi Arabia.