Meenakshi Ranasinghe

Dr. Meenakshi Ranasinghe


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2020 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
Mohamed AteiaMohamed Ateia
Mohamed Ateia
MRMeenakshi Ranasinghe
Meenakshi Ranasinghe
RARoman Akasov
Roman Akasov
JAJeffrey Anker
Jeffrey Anker
DWDaniel Whitehead
Daniel Whitehead
Frank AlexisFrank Alexis
Frank Alexis
The synthesis and application of gold nanoparticles (AuNPs) have attracted much attention due to their interesting optical and chemical properties, as well as their utility in imaging, therapeutics, sensors, electronics, and catalysis. AuNPs are synthesized using multiple approaches, followed by chemical modification or encapsulation, to enhance their colloidal stability, biocompatibility, and targeting. Here, we report the one-step synthesis of gold–polyester nanoparticles for use as an imaging agent. The AuNPs were prepared inside polymeric NPs by means of ultraviolet irradiation of a gold salt in the presence of Irgacure I-2959 photoinitiator. We monitored the kinetic growth and nucleation of AuNPs (in vitro and ex vivo) over time using spectral analysis. Moreover, we investigated the cytotoxicity, localized plasmonic surface resonance (LSPR), and cellular imaging capabilities of the Au–polyester nanoparticles. The resulting Au–polyester NPs were characterized by Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), X-ray diffraction (XRD), dynamic light scattering (DLS), and transmission electron microscopy (TEM) to probe their chemical structure, size, zeta potential (ζ), and morphology, respectively. Furthermore, in vitro experiments showed that the NP formulation is stable over time and exhibits negligible toxicity against 3T3 fibroblast and U-87 MG glioblastoma cells. The results also demonstrated that the Au–polyester NPs exhibit excellent cellular imaging properties. This one-step strategy goes beyond current syntheses of gold–polyester nanoparticles because it can be used to synthesize the imaging agent in situ (i.e., in living cells) in lieu of conventional ex situ approaches.

21 September 2021 in RSC Advances
Verified
Journal Article
Open access
PDF file
MRMeenakshi Ranasinghe
Meenakshi Ranasinghe
MAMohammad Arifuzzaman
Mohammad Arifuzzaman
ARApeksha Rajamanthrilage
Apeksha Rajamanthrilage
WWW. R. Willoughby
W. R. Willoughby
ADAshley Dickey
Ashley Dickey
JAJeffrey Anker
Jeffrey Anker
We synthesized and characterized Eu and Tb doped NaGdF4 nanophosphors which generate visible light when excited by a focused X-ray beam. High resolution images were acquired through tissue by measuring light intensity vs. X-ray beam position.

15 May 2022 in Photonics
Verified
Journal Article
Open access
PDF file
MAMohammad Arifuzzaman
Mohammad Arifuzzaman
MRMeenakshi Ranasinghe
Meenakshi Ranasinghe
ARApeksha Rajamanthrilage
Apeksha Rajamanthrilage
SBSriparna Bhattacharya
Sriparna Bhattacharya
JAJeffrey Anker
Jeffrey Anker
X-ray luminescence tomography (XLT) detects X-ray scintillators contrast agents using a focused or collimated X-ray beam to provide high spatial resolution excitation through thick tissue. The approach requires bright nanophosphors that are either synthesized or purchased. However, currently available commercial nanophosphors are mostly composed of a polydisperse mixture of several micro- to nano-sized particles that are unsuitable for biomedical imaging applications because of their size and aggregated form. Here, we demonstrate a fast and robust method to obtain uniform nano to submicron phosphor particles from a commercial source of polydisperse Eu- and Tb-doped Gd2O2S particles by separating the smaller particles present using gravitational and centrifugal sedimentation. In contrast to ball milling for 15–60 min, which drastically degraded the particles’ brightness while reducing their size, our sedimentation method enabled the extraction of comparatively bright nanophosphors (≈100–300 nm in size) with a luminescence intensity of ≈10–20% of the several micron particles in the sample. Moreover, if scale up for higher yielding is required, the sedimentation process can be accelerated using fixed-angle and/or swinging bucket rotating centrifugation. Finally, after separation and characterization, nano and submicron phosphors were suspended and imaged through 5 mm thick porcine tissue using our in-house-built scanning X-ray induced luminescence chemical imaging (XELCI) system.

12 May 2021 in Nano Select
Verified
Journal Article
Open access
PDF file
FAFathima S. Ameer
Fathima S. Ameer
MRMeenakshi Ranasinghe
Meenakshi Ranasinghe
SVShilpa Varahagiri
Shilpa Varahagiri
DBDonald W. Benza
Donald W. Benza
LHLongyu Hu
Longyu Hu
JAJeffrey Anker
Jeffrey Anker
The optical and chemical properties of gold and silver nanoparticles make them useful for many applications, including surface enhanced spectroscopy‐based biosensors, photostable colorants, enhanced photovoltaic, and nanoscale optical elements. We report a simple technique to generate patterns of gold and silver nanoparticles with controlled shape and shape‐dependent optical properties using metal stamps to impress them onto a glass substrate or flexible polymers. The pressure flattens the nanoparticles, converting initially spherical nanoparticles into discs with reduced height and increased diameter. This deformation causes their localized surface plasmon resonance wavelength to red‐shift. Nanoparticles were characterized by electron microscopy, atomic force microscopy, and dark field optical scattering spectroscopy. The deformed nanoparticle patterns had a lateral resolution limited by the nanoparticle diameter (single particles are partly flattened only where they contact the stamp). The method also (i) transfers the stamp's topography, with smooth stamps generating flattened nanoparticles with uniform height, and small changes in stamp height are evident in the nanoparticle height and scattering wavelength, and (ii) allows facile removal of undeformed nanoparticles using scotch tape, and patterns of deformed nanoparticles can be transferred to a flexible polymer film. The patterning process is simple and inexpensive. It can be performed by hand for demonstrations or artistic applications, with controlled force for plasmonics research, and potentially automated on reel‐to‐reel presses for large scale production.

2 June 2020 in ChemRxiv
Verified
Preprint
Open access
UUUnaiza Uzair
Unaiza Uzair
CJChloe Johnson
Chloe Johnson
SBShayesteh Beladi-Behbahani
Shayesteh Beladi-Behbahani
DBDonald Benza
Donald Benza
YRYash Raval
Yash Raval
JAJeffrey Anker
Jeffrey Anker
We describe a material that allows for high spatial resolution pH mapping through tissue using X-ray excited luminescence chemical imaging (XELCI). This is especially useful for detecting implant associated infection and elucidating how the local biochemical environment changes during infection and treatment. To acquire one pixel in the image, a focused X-ray beam irradiates a small region of scintillators coated on the implant and the X-ray excited optical luminescence spectrum is modulated by indicator dyes to provide a chemically sensitive measurement with low background. Scanning the X-ray beam across the implant surface generates high spatial resolution chemical measurements. Two associated challenges are 1) to make robust sensors that can be implanted in tissue to measure local chemical concentrations and specifically for metal orthopedic implants, and 2) to conformally coat the implant surface with scintillators and pH indicator dyes in order to make measurements over a large area. Previously, we have physically pressed or glued a pH-sensitive hydrogel sensor to the surface of an implant, but this is impractical for imaging over large irregular device areas such as an orthopedic plate with holes and edges. Herein we describe a chemically sensitive and biocompatible XELI sensor material containing scintillator particles (Gd2O2S:Eu) and a pH sensitive hydrogel coating using a roughened epoxy coating. A two-part commercial grade epoxy film was tested and found to make the coating of pH sensitive layer adhere better to the titanium surface. Sugar and salt particles were added to the surface of the epoxy as it cured to create a roughened surface and increase surface area. On this roughened surface, a secondary layer of diacrylated polyethylene glycol (PEG) hydrogel, containing a pH sensitive dye, was polymerized. This layer was found to adhere well to the epoxy-coated implant unlike other previously tested polymer surfaces which delaminated when exposed to water or humidity. The focused X-ray beam enabled 0.5 mm spatial resolution through 1 cm thick tissue. The pH sensor coated orthopedic plate was imaged with XELCI through tissue with different pH to acquire a calibration curve. The plates were also imaged through tissue with low pH region from a Staphylococcus aureus biofilm grown on one section. These studies demonstrate the use of pH sensor coated orthopedic plates for mapping the surface pH through tissue during biofilm formation using XELCI.

1 June 2020 in ChemRxiv
Verified
Preprint
Open access
UUUnaiza Uzair
Unaiza Uzair
CJChloe Johnson
Chloe Johnson
SBShayesteh Beladi-Behbahani
Shayesteh Beladi-Behbahani
DBDonald Benza
Donald Benza
YRYash Raval
Yash Raval
JAJeffrey Anker
Jeffrey Anker
We describe a material that allows for high spatial resolution pH mapping through tissue using X-ray excited luminescence chemical imaging (XELCI). This is especially useful for detecting implant associated infection and elucidating how the local biochemical environment changes during infection and treatment. To acquire one pixel in the image, a focused X-ray beam irradiates a small region of scintillators coated on the implant and the X-ray excited optical luminescence spectrum is modulated by indicator dyes to provide a chemically sensitive measurement with low background. Scanning the X-ray beam across the implant surface generates high spatial resolution chemical measurements. Two associated challenges are 1) to make robust sensors that can be implanted in tissue to measure local chemical concentrations and specifically for metal orthopedic implants, and 2) to conformally coat the implant surface with scintillators and pH indicator dyes in order to make measurements over a large area. Previously, we have physically pressed or glued a pH-sensitive hydrogel sensor to the surface of an implant, but this is impractical for imaging over large irregular device areas such as an orthopedic plate with holes and edges. Herein we describe a chemically sensitive and biocompatible XELI sensor material containing scintillator particles (Gd 2 O 2 S:Eu) and a pH sensitive hydrogel coating using a roughened epoxy coating. A two-part commercial grade epoxy film was tested and found to make the coating of pH sensitive layer adhere better to the titanium surface. Sugar and salt particles were added to the surface of the epoxy as it cured to create a roughened surface and increase surface area. On this roughened surface, a secondary layer of diacrylated polyethylene glycol (PEG) hydrogel, containing a pH sensitive dye, was polymerized. This layer was found to adhere well to the epoxy-coated implant unlike other previously tested polymer surfaces which delaminated when exposed to water or humidity. The focused X-ray beam enabled 0.5 mm spatial resolution through 1 cm thick tissue. The pH sensor coated orthopedic plate was imaged with XELCI through tissue with different pH to acquire a calibration curve. The plates were also imaged through tissue with low pH region from a Staphylococcus aureus biofilm grown on one section. These studies demonstrate the use of pH sensor coated orthopedic plates for mapping the surface pH through tissue during biofilm formation using XELCI.