Mohammad Arifuzzaman

Dr. Mohammad Arifuzzaman

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2019 in The Analyst
Verified
Journal Article
Closed access
PDF file
MAMohammad Arifuzzaman
Mohammad Arifuzzaman
PMPaul W. Millhouse
Paul W. Millhouse
YRYash Raval
Yash Raval
TPThomas B. Pace
Thomas B. Pace
CBCaleb J. Behrend
Caleb J. Behrend
JAJeffrey Anker
Jeffrey Anker
The constructed biosensor enhances the capability of traditional plain film radiography, enabling the noninvasive measurement of postoperative infection indicating chemical concentration such as pH on the implant surfaces.

3 June 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Mohamed AteiaMohamed Ateia
Mohamed Ateia
AMAhmed S. Montaser
Ahmed S. Montaser
MAMohammad Arifuzzaman
Mohammad Arifuzzaman
MPMegan Pitz
Megan Pitz
khouloud jlassikhouloud jlassi
khouloud jlassi
DWDaniel Whitehead
Daniel Whitehead
In this study we developed electrospun cellulose acetate nanofibers (CANFs) that were loaded with a model non-steroidal anti-inflammatory drug (NSAID) (ibuprofen, Ib) and coated with poly(acrylamide) (poly-AAm) hydrogel polymer using two consecutive steps: an electrospinning process followed by photopolymerization of AAm. Coated and non-coated CANF formulations were characterized by several microscopic and spectroscopic techniques to evaluate their physicochemical properties. An analysis of the kinetic release profile of Ib showed noticeable differences due to the presence or absence of the poly-AAm hydrogel polymer. Poly-AAm coating facilitated a constant release rate of drug as opposed to a more conventional burst release. The non-coated CANFs showed low cumulative drug release concentrations (ca. 35 and 83% at 5 and 10% loading, respectively). Conversely, poly-AAm coated CANFs were found to promote the release of drug (ca. 84 and 99.8% at 5 and 10% loading, respectively). Finally, the CANFs were found to be superbly cytocompatible.

21 September 2021 in RSC Advances
Verified
Journal Article
Open access
PDF file
MRMeenakshi Ranasinghe
Meenakshi Ranasinghe
MAMohammad Arifuzzaman
Mohammad Arifuzzaman
ARApeksha Rajamanthrilage
Apeksha Rajamanthrilage
WWW. R. Willoughby
W. R. Willoughby
ADAshley Dickey
Ashley Dickey
JAJeffrey Anker
Jeffrey Anker
We synthesized and characterized Eu and Tb doped NaGdF4 nanophosphors which generate visible light when excited by a focused X-ray beam. High resolution images were acquired through tissue by measuring light intensity vs. X-ray beam position.

15 May 2022 in Photonics
Verified
Journal Article
Open access
PDF file
MAMohammad Arifuzzaman
Mohammad Arifuzzaman
MRMeenakshi Ranasinghe
Meenakshi Ranasinghe
ARApeksha Rajamanthrilage
Apeksha Rajamanthrilage
SBSriparna Bhattacharya
Sriparna Bhattacharya
JAJeffrey Anker
Jeffrey Anker
X-ray luminescence tomography (XLT) detects X-ray scintillators contrast agents using a focused or collimated X-ray beam to provide high spatial resolution excitation through thick tissue. The approach requires bright nanophosphors that are either synthesized or purchased. However, currently available commercial nanophosphors are mostly composed of a polydisperse mixture of several micro- to nano-sized particles that are unsuitable for biomedical imaging applications because of their size and aggregated form. Here, we demonstrate a fast and robust method to obtain uniform nano to submicron phosphor particles from a commercial source of polydisperse Eu- and Tb-doped Gd2O2S particles by separating the smaller particles present using gravitational and centrifugal sedimentation. In contrast to ball milling for 15–60 min, which drastically degraded the particles’ brightness while reducing their size, our sedimentation method enabled the extraction of comparatively bright nanophosphors (≈100–300 nm in size) with a luminescence intensity of ≈10–20% of the several micron particles in the sample. Moreover, if scale up for higher yielding is required, the sedimentation process can be accelerated using fixed-angle and/or swinging bucket rotating centrifugation. Finally, after separation and characterization, nano and submicron phosphors were suspended and imaged through 5 mm thick porcine tissue using our in-house-built scanning X-ray induced luminescence chemical imaging (XELCI) system.

22 September 2017 in ChemRxiv
Verified
Preprint
Open access
MAMohammad Arifuzzaman
Mohammad Arifuzzaman
PMPaul W. Millhouse
Paul W. Millhouse
YRYash Raval
Yash Raval
TPThomas B. Pace
Thomas B. Pace
CBCaleb J. Behrend
Caleb J. Behrend
JAJeffrey Anker
Jeffrey Anker
A biomedical sensor is designed to noninvasively measure local pH changes on the surface of implanted devices for detecting and monitoring implant-associated infection using plain radiography. The sensor comprises a radiopaque pin embedded within a polyacrylic acid-based hydrogel. pH-modulated hydrogel expansion and contraction is determined by radiographically measuring the pin position. The sensor was calibrated in a series of standard pH buffers, and tested in a bacterial growth culture. The sensor calibration was insensitive to changes in temperature and ionic strength within the normal physiological range. The response time depended on sensor thickness, and was approximately 30 min for 1 mm thick films. Radiographic measurements were also performed through tissue and bone with the sensor attached to an orthopedic plate fixated to a human cadaver tibia. Plain radiographs were selected for readout since X-rays are routinely used in inpatient and outpatient settings for structural or anatomical information. The chemically-responsive hydrogel sensors can provide additional functional information in a clinical setting by indicating local chemical concentrations near the implant surface using routinely obtained radiographs.

28 August 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
ARApeksha Rajamanthrilage
Apeksha Rajamanthrilage
MAMohammad Arifuzzaman
Mohammad Arifuzzaman
PMPaul W. Millhouse
Paul W. Millhouse
TPThomas B. Pace
Thomas B. Pace
CBCaleb J. Behrend
Caleb J. Behrend
JAJeffrey Anker
Jeffrey Anker
We describe a fluidic X-ray visualized strain indicator under applied load (X-VISUAL) to quantify orthopedic plate strain and inform rehabilitative care. This sensor uses a liquid-level gauge with hydro-mechanical amplification and is visualized in plain radiographs which are routinely acquired during patient recovery to find pathologies but are usually insufficient to quantify fracture stiffness. The sensor has two components: a stainless-steel lever which attaches to the plate, and an acrylic fluidic component which sits between the plate and lever. The fluidic component has a reservoir filled with radio-dense solution and an adjoining capillary wherein the fluid level is measured. When the plate bends under load, the lever squeezes the reservoir, which pushes the fluid along the channel. A tibial osteotomy model (5 mm gap) was used to simulate an unstable fracture, and allograft repair used to simulate a stiffer healed fracture. A cadaveric tibia and a mechanically equivalent composite tibia mimic were cyclically loaded five times (0 – 400 N axial force) while fluid displacement was measured from radiographs. The sensor displayed reversible and repeatable behavior with a slope of 0.096 mm/kg and fluid level noise of 50 to 80 micrometers (equivalent to 5-10 N). The allograft-repaired composite fracture was 13 times stiffer than the unstable fracture. An analysis of prior external fracture fixation studies and fatigue curves for internal plates indicates that the threshold for safe weight bearing should be 1/5 th −1/10 th of the initial bending for an unstable fracture. The precision of our device (<2% body weight) should thus be sufficient to track fracture healing from unstable through safe weight bearing.