Jing Wang

Dr. Jing Wang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
YJYangkang Jiang
Yangkang Jiang
XZXiaoqun Zhang
Xiaoqun Zhang
KSKe Sheng
Ke Sheng
TNTianye Niu
Tianye Niu
YXYi Xue
Yi Xue
XHXi Hu
Xi Hu
Objective: Dual-energy CT (DECT) strengthens the material characterization and quantification due to its capability of material discrimination. The image-domain multi-material decomposition (MMD) via matrix inversion suffers from serious degradation of the signal-to-noise ratios (SNRs) of the decomposed images and thus the clinical application of DECT is limited. In this work, we propose a noise suppression algorithm based on the noise propagation for image-domain MMD. Methods: The noise in the decomposed images only distributes in two perpendicular directions and is suppressed by estimating the center of mass of the same-material pixel group vertically along the principal axis where the noise disturbance is minimal. The proposed method is evaluated using the line-pair and contrast-rod slices of the Catphan©600 phantom and one patient data set. We compared the proposed method with the direct inversion and the block-matching and three-dimensional (BM3D) filtration methods. Results: The results of Catphan©600 phantom and the patient show that the proposed method successfully suppresses the noise of the basis material images by one order of magnitude and preserves the spatial resolution of the decomposed images. Compared with the BM3D filtration method, the proposed method maintains the texture distribution of the decomposed images at the same SNR and the accuracy of the electron density measurement. Conclusion: The algorithm achieves effective noise suppression compared with the BM3D filtration while maintaining the spatial distribution of the decomposed material images. It is thus attractive for advanced clinical applications using DECT.

7 August 2025 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CLChuan Lyu
Chuan Lyu
DYDian Yang
Dian Yang
XXXu Xu
Xu Xu
YCYu Cai
Yu Cai
Bo LiangBo Liang
Bo Liang
JWJing Wang
Jing Wang
The rapid and sensitive detection of specific protein biomarkers is essential for early diagnosis and monitoring of diseases. Magnetic digital microfluidics (MDMF), capable of integrating and miniaturizing chemiluminescence immunoassay (CLIA), offers significant advantages for biomarker detection, including high flexibility, high efficiency, and low sample consumption. Magnetic bead manipulation, as a key component of MDMF, plays a critical role in improving detection sensitivity and accuracy within a short analysis time. In this study, we proposed an automated MDMF-based CLIA system and developed a compact analyzer, enabling faster and more sensitive biomarker detection through optimized magnetic bead manipulation. The system employs a film-sandwiched microfluidic chip, along with a specially designed spliced magnet to generate a stronger and more concentrated magnetic force, significantly enhancing the control over the motion of magnetic beads. By using the magnet to drive magnetic beads through water-in-oil droplets, the system automates the entire CLIA workflow. Through theoretical analysis, simulations, and experiments, we validate the system's advantages in magnetic bead aggregation and transfer, achieving a high magnetic bead collection rate of 97.07% with excellent cleaning effect after three cleaning rounds. The detection of cardiac troponin I (cTnI) can be completed within 10 min, with a limit of detection (LOD) of 2.09 pg mL−1, a detection range of 0.01 to 20 ng mL−1, and a strong linear correlation with conventional CLIA (R2 = 0.9961). This system achieves rapid, sensitive, and automated CLIA, making it a promising platform for clinical diagnostics.

11 March 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
BDBo Dong
Bo Dong
CLChenxi Lu
Chenxi Lu
XHXi Hu
Xi Hu
YZYang Zhao
Yang Zhao
Hongjiang WeiHongjiang Wei
Hongjiang Wei
JWJing Wang
Jing Wang
Robotic cochlear implantation is an effective way to restore the hearing of hearing-impaired patients, and facial nerve recognition is the key to the operation. However, accurate facial nerve segmentation is a challenging task, mainly for two key issues: (1) the facial nerve area is very small in image, and there are many similar areas; (2) low contrast of the border between the facial nerve and the surrounding tissues increases the difficulty. In this work, we propose an end-to-end neural network, called FNSegNet, with two stages to solve these problems. Specifically, in the coarse segmentation stage, we first adopt three search identification modules to capture small objects by expanding the receptive field from high-level features and combine an effective pyramid fusion module to fuse. In the refine segmentation stage, we use a decoupling optimization module to establish the relationship between the central region and the boundary details of facial nerve by decoupling the boundary and center area. Meanwhile, we feed them into a spatial attention module to correct the conflict regions. Extensive experiments on the challenging dataset demonstrate that the proposed FNSegNet significantly improves the segmentation accuracy (0.858 on Dice, 0.363 mm on 95% Hausdorff distance), and reduces the computational complexity (13.33G on FLOPs, 9.86M parameters).

30 September 2024 in Magnetochemistry
Verified
Journal Article
Open access
PDF file
CLChuan Lyu
Chuan Lyu
YJYu Jiang
Yu Jiang
ZDZhen Dai
Zhen Dai
XXXu Xu
Xu Xu
YCYu Cai
Yu Cai
JWJing Wang
Jing Wang
The magnetic separation and cleaning module, as a core component of the fully automated chemiluminescence immunoassay (CLIA) analyzer, encounters issues including high magnetic bead loss rate, long cleaning time, and poor cleaning effect. Based on a simulation analysis using COMSOL, we proposed a novel magnetic separation and cleaning module applied to a fully automated CLIA analyzer. The module adopted a method of arranging spliced rectangular magnets on opposite sides, where the same polarity faced each other, as well as a three-stage magnetic bead collection method. With the proposed method, the total cleaning process can be accomplished within 225 s; the total magnetic bead loss rate over three rounds of cleaning is 6.03%, whereas that of traditional instruments is 25.85%; the coefficient of variation (CV) of the magnetic bead loss rate is less than 0.5%; effective cleaning of free markers is achieved under various sample conditions. Compared with traditional CLIA instruments, this method comprehensively improves key performance indicators of the magnetic separation and cleaning module, providing a reference for similar modules in fully automated CLIA analyzers and positively impacting the accuracy of CLIA for the detection of disease biomarkers.

25 July 2022
Verified
Book Chapter
Closed access
PDF file
CLChenxi Lu
Chenxi Lu
BDBo Dong
Bo Dong
XHXi Hu
Xi Hu
YZYang Zhao
Yang Zhao
Hongjiang WeiHongjiang Wei
Hongjiang Wei
JWJing Wang
Jing Wang

30 June 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
XXXu Xu
Xu Xu
ZXZhongyi Xu
Zhongyi Xu
CLChuan Lyu
Chuan Lyu
Bo LiangBo Liang
Bo Liang
CZCongcong Zhou
Congcong Zhou
JWJing Wang
Jing Wang
Driven by the rising demand for point-of-care testing (POCT) in aging societies, accurate temperature regulation of reaction solutions has become a core technical bottleneck for miniaturized chemiluminescence immunoassay systems, since conventional indirect control strategies inevitably produce systematic deviations. To tackle this challenge, we present an integrated solution that couples multiphysics simulation, data-driven temperature estimation modeling, and embedded hardware design. We constructed a COMSOL heat transfer model to analyze the thermal performance of the microfluidic chip. Meanwhile, a grey wolf optimization (GWO) enhanced long short-term memory (LSTM) network was developed to infer the unmeasured actual reaction solution temperature based on accessible parameters, including heating voltage, ambient temperature and substrate temperature. The obtained temperature estimation was then fed back to a fuzzy PID controller for closed-loop regulation. Experimental results demonstrated that the GWO-LSTM model limited the estimation error within 0.3 °C, and the steady-state temperature control accuracy reached ±0.2 °C or higher under fluctuating ambient conditions and diverse initial states. For cardiac troponin I (cTnI) detection, the proposed system shortened the incubation duration and reduced the coefficient of variation from 10.77% to 2.69%. This work addresses the key bottleneck restricting precise temperature control in microfluidic chemiluminescence analyzers, which provides robust technical support for the development of next-generation high-performance POCT instruments.