This study proposed a refined BP prediction strategy that using single-channel photoplethysmography (PPG) signals to stratify populations by cardiovascular status before BP estimation. Combining demographic characteristics (age, gender) and pulse wave morphological features, the random forest was applied to screen two kinds of typical cardiovascular diseases (CVDs), with an accuracy of 92.2%. A deep learning model (BiLSTM-At) was proposed to estimate the long-term BP trend for different CVD groups. Transfer learning technique was used for personalized modeling to reduce computational complexity while improving performance. The method was validated on 255 patients with different CVDs. The mean absolute errors (MAEs) of systolic blood pressure (SBP) and diastolic blood pressure (DBP) estimation were 2.815 mmHg and 1.876 mmHg for normal subjects, 3.024 mmHg and 1.334 mmHg for AF subjects, and 4.444 mmHg and 2.549 mmHg for CA subjects. The results met the American Association for the Advancement of Medical Instrumentations (AAMI) and British Hypertension Society (BHS) Class A criteria. This indicated that our strategy has good performance and can realize long-term monitoring of BP through a small batch samples, with the potential to implement real-time monitoring in healthy devices.
The ankle joint is one of the important joints of the human body to maintain the ability to walk. Diseases such as stroke and ankle osteoarthritis could weaken the body’s ability to control joints, causing people’s gait to be out of balance. Ankle–foot orthoses can assist users with neuro/muscular or ankle injuries to restore their natural gait. Currently, passive ankle–foot orthoses are mostly designed to fix the ankle joint and provide support for walking. With the development of materials, sensing, and control science, semi-active orthoses that release mechanical energy to assist walking when needed and can store the energy generated by body movement in elastic units, as well as active ankle–foot orthoses that use external energy to transmit enhanced torque to the ankle, have received increasing attention. This article reviews the development process of ankle–foot orthoses and proposes that the integration of new ankle–foot orthoses with rehabilitation technologies such as monitoring or myoelectric stimulation will play an important role in reducing the walking energy consumption of patients in the study of human-in-the-loop models and promoting neuro/muscular rehabilitation.
2 May 2023 in Biomedical Signal Processing and Control
Objective: In this paper, a miniaturized wearable core body temperature (CBT) monitoring system based on the dual heat flux (DHF) principle was developed. Approach: By interspersing calcium carbonate powder in PolyDimethylsiloxane (PDMS), a reformative heat transfer medium was produced to reduce the thermal equilibrium time. Besides, a least mean square (LMS) algorithm based active noise cancellation (ANC) method was adopted to diminish the impact of ambient temperature fluctuations. Theoretical analyses, finite element simulation, experiments on a hot plate and human volunteers were performed. Main results: The results showed that the proposed system had the advantages of small size, reduced initial time (~23.5 min), and good immunity to fluctuations of the air temperature. For the range of 37–41 °C on the hot plate, the error compared with a Fluke high accuracy thermometer was 0.08 ± 0.20 °C. In the human experiments, the measured temperature in the rest trial (34 subjects) had a difference of 0.13 ± 0.22 °C compared with sublingual temperature, while a significant increase of 1.36 ± 0.44 °C from rest to jogging was found in the exercise trial (30 subjects). Significance: This system has the potential for reliable continuous CBT measurement in rest and can reflect CBT variations during exercise.
1 November 2021 in Sensors and Actuators A: Physical