Philippe C. Cattin

Prof. Dr. Philippe C. Cattin

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2022 in Neurology Neuroimmunology & Neuroinflammation
Verified
Journal Article
Open access
PDF file
JMJannis Müller
Jannis Müller
TSTim Sinnecker
Tim Sinnecker
MWMaria Janina Wendebourg
Maria Janina Wendebourg
RSRegina Schläger
Regina Schläger
JKJens Kuhle
Jens Kuhle
ÖYÖzgür Yaldizli
Özgür Yaldizli
Background and Objectives The choroid plexus has been shown to play a crucial role in CNS inflammation. Previous studies found larger choroid plexus in multiple sclerosis (MS) compared with healthy controls. However, it is not clear whether the choroid plexus is similarly involved in MS and in neuromyelitis optica spectrum disorder (NMOSD). Thus, the aim of this study was to compare the choroid plexus volume in MS and NMOSD. Methods In this retrospective, cross-sectional study, patients were included by convenience sampling from 4 international MS centers. The choroid plexus of the lateral ventricles was segmented fully automatically on T1-weighted MRI sequences using a deep learning algorithm (Multi-Dimensional Gated Recurrent Units). Uni- and multivariable linear models were applied to investigate associations between the choroid plexus volume, clinically meaningful disease characteristics, and MRI parameters. Results We studied 180 patients with MS and 98 patients with NMOSD. In total, 94 healthy individuals and 47 patients with migraine served as controls. The choroid plexus volume was larger in MS (median 1,690 µL, interquartile range [IQR] 648 µL) than in NMOSD (median 1,403 µL, IQR 510 µL), healthy individuals (median 1,533 µL, IQR 570 µL), and patients with migraine (median 1,404 µL, IQR 524 µL; all p < 0.001), whereas there was no difference between NMOSD, migraine, and healthy controls. This was also true when adjusted for age, sex, and the intracranial volume. In contrast to NMOSD, the choroid plexus volume in MS was associated with the number of T2-weighted lesions in a linear model adjusted for age, sex, total intracranial volume, disease duration, relapses in the year before MRI, disease course, Expanded Disability Status Scale score, disease-modifying treatment, and treatment duration (beta 4.4; 95% CI 0.78–8.1; p = 0.018). Discussion This study supports an involvement of the choroid plexus in MS in contrast to NMOSD and provides clues to better understand the respective pathogenesis.

9 October 2024
Verified
Book Chapter
Closed access
PDF file
PFPaul Friedrich
Paul Friedrich
JWJulia Wolleb
Julia Wolleb
FBFlorentin Bieder
Florentin Bieder
ADAlicia Durrer
Alicia Durrer
PCPhilippe C. Cattin
Philippe C. Cattin

19 November 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
LBLina M. Beltrán Bernal
Lina M. Beltrán Bernal
FCFerda Canbaz
Ferda Canbaz
ADAntoine Droneau
Antoine Droneau
NFNiklaus F. Friederich
Niklaus F. Friederich
PCPhilippe C. Cattin
Philippe C. Cattin
Azhar ZamAzhar Zam
Azhar Zam
The microsecond Er:YAG pulsed laser with a wavelength of λ = 2.94 μm has been widely used in the medical field, particularly for ablating dental tissues. Since bone and dental tissues have similar compositions, consisting of mineralized and rigid structures, the Er:YAG laser represents a promising tool for laserosteotomy applications. In this study, we explored the use of the Er:YAG laser for deep bone ablation, in an attempt to optimize its performance and identify its limitations. Tissue irrigation and the laser settings were optimized independently. We propose an automated irrigation feedback system capable of recognizing the temperature of the tissue and delivering water accordingly. The irrigation system used consists of a thin 50 μm diameter water jet. The water jet was able to penetrate deep into the crater during ablation, with a laminar flow length of 15 cm, ensuring the irrigation of deeper layers unreachable by conventional spray systems. Once the irrigation was optimized, ablation was considered independently of the irrigation water. In this way, we could better understand and adjust the laser parameters to suit our needs. We obtained line cuts as deep as 21 mm without causing any visible thermal damage to the surrounding tissue. The automated experimental setup proposed here has the potential to support deeper and faster ablation in laserosteotomy applications.

2 March 2018 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
HAHamed Abbasi
Hamed Abbasi
GRGeorg Rauter
Georg Rauter
Raphael GuzmanRaphael Guzman
Raphael Guzman
PCPhilippe C. Cattin
Philippe C. Cattin
Azhar ZamAzhar Zam
Azhar Zam
In laserosteotomy, it is vital to avoid thermal damage of the surrounding tissue, such as carbonization, since carbonization does not only deteriorate the ablation efficiency but also prolongs the healing process. The state-of-the-art method to avoid carbonization is irrigation systems; however, it is difficult to determine the desired flow rate of the air and cooling water based on previous experiments without online monitoring of the bone surface. Lack of such feedback during the ablation process can cause carbonization in case of a possible error in the irrigation system or slow down the cutting process when irrigating with too much cooling water. The aim of this paper is to examine laser-induced breakdown spectroscopy as a potential tool for autocarbonization detection in laserosteotomy. By monitoring the laser-driven plasma generated during nanosecond pulse ablation of porcine bone samples, carbonization is hypothesized to be detectable. For this, the collected spectra were analyzed based on variation of a specific pair of emission line ratios in both groups of samples: normal and carbonized bone. The results confirmed a high accuracy of over 95% in classifying normal and carbonized bone.

27 January 2024 in Communications Engineering
Verified
Journal Article
Open access
PDF file
SRSamaneh Manavi Roodsari
Samaneh Manavi Roodsari
SFSara Freund
Sara Freund
MAMartin Angelmahr
Martin Angelmahr
CSCarlo Seppi
Carlo Seppi
GRGeorg Rauter
Georg Rauter
PCPhilippe C. Cattin
Philippe C. Cattin
Fiber optic shape sensing is an innovative technology that has enabled remarkable advances in various navigation and tracking applications. Although the state-of-the-art fiber optic shape sensing mechanisms can provide sub-millimeter spatial resolution for off-axis strain measurement and reconstruct the sensor’s shape with high tip accuracy, their overall cost is very high. The major challenge in more cost-effective fiber sensor alternatives for providing accurate shape measurement is the limited sensing resolution in detecting shape deformations. Here, we present a data-driven technique to overcome this limitation by removing strain measurement, curvature estimation, and shape reconstruction steps. We designed an end-to-end convolutional neural network that is trained to directly predict the sensor’s shape based on its spectrum. Our fiber sensor is based on easy-to-fabricate eccentric fiber Bragg gratings and can be interrogated with a simple and cost-effective readout unit in the spectral domain. We demonstrate that our deep-learning model benefits from undesired bending-induced effects (e.g., cladding mode coupling and polarization), which contain high-resolution shape deformation information. These findings are the preliminary steps toward a low-cost yet accurate fiber shape sensing solution for detecting complex multi-bend deformations.

20 April 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
YBYakub A. Bayhaqi
Yakub A. Bayhaqi
AHArsham Hamidi
Arsham Hamidi
FCFerda Canbaz
Ferda Canbaz
ANAlexander A. Navarini
Alexander A. Navarini
PCPhilippe C. Cattin
Philippe C. Cattin
Azhar ZamAzhar Zam
Azhar Zam
Laser osteotomy promises precise cutting and minor bone tissue damage. We proposed Optical Coherence Tomography (OCT) to monitor the ablation process toward our smart laser osteotomy approach. The OCT image is helpful to identify tissue type and provide feedback for the ablation laser to avoid critical tissues such as bone marrow and nerve. Furthermore, in the implementation, the tissue classifier’s accuracy is dependent on the quality of the OCT image. Therefore, image denoising plays an important role in having an accurate feedback system. A common OCT image denoising technique is the frame-averaging method. Inherent to this method is the need for multiple images, i.e., the more images used, the better the resulting image quality. However, this approach comes at the price of increased acquisition time and sensitivity to motion artifacts. To overcome these limitations, we applied a deep-learning denoising method capable of imitating the frame-averaging method. The resulting image had a similar image quality to the frame-averaging and was better than the classical digital filtering methods. We also evaluated if this method affects the tissue classifier model’s accuracy that will provide feedback to the ablation laser. We found that image denoising significantly increased the accuracy of the tissue classifier. Furthermore, we observed that the classifier trained using the deep learning denoised images achieved similar accuracy to the classifier trained using frame-averaged images. The results suggest the possibility of using the deep learning method as a pre-processing step for real-time tissue classification in smart laser osteotomy.