Yakub Aqib Bayhaqi

Yakub Aqib Bayhaqi

Auto-generated profile, based on publicly available information

Yakub Aqib Bayhaqi

Casey Eye Institute, Oregon Health and Science University, Portland, OR, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
YBYakub A. Bayhaqi
Yakub A. Bayhaqi
AHArsham Hamidi
Arsham Hamidi
FCFerda Canbaz
Ferda Canbaz
ANAlexander A. Navarini
Alexander A. Navarini
PCPhilippe C. Cattin
Philippe C. Cattin
Azhar ZamAzhar Zam
Azhar Zam
Laser osteotomy promises precise cutting and minor bone tissue damage. We proposed Optical Coherence Tomography (OCT) to monitor the ablation process toward our smart laser osteotomy approach. The OCT image is helpful to identify tissue type and provide feedback for the ablation laser to avoid critical tissues such as bone marrow and nerve. Furthermore, in the implementation, the tissue classifier’s accuracy is dependent on the quality of the OCT image. Therefore, image denoising plays an important role in having an accurate feedback system. A common OCT image denoising technique is the frame-averaging method. Inherent to this method is the need for multiple images, i.e., the more images used, the better the resulting image quality. However, this approach comes at the price of increased acquisition time and sensitivity to motion artifacts. To overcome these limitations, we applied a deep-learning denoising method capable of imitating the frame-averaging method. The resulting image had a similar image quality to the frame-averaging and was better than the classical digital filtering methods. We also evaluated if this method affects the tissue classifier model’s accuracy that will provide feedback to the ablation laser. We found that image denoising significantly increased the accuracy of the tissue classifier. Furthermore, we observed that the classifier trained using the deep learning denoised images achieved similar accuracy to the classifier trained using frame-averaged images. The results suggest the possibility of using the deep learning method as a pre-processing step for real-time tissue classification in smart laser osteotomy.

16 March 2021 in Biomedical Optics Express
Verified
Journal Article
Closed access
AHArsham Hamidi
Arsham Hamidi
YBYakub A. Bayhaqi
Yakub A. Bayhaqi
FCFerda Canbaz
Ferda Canbaz
ANAlexander A. Navarini
Alexander A. Navarini
PCPhilippe C. Cattin
Philippe C. Cattin
Azhar ZamAzhar Zam
Azhar Zam
This work presents a long-range and extended depth-of-focus optical coherence tomography (OCT) system using a Bessel-like beam (BLB) as a visual feedback system during laser osteotomy. We used a swept-source OCT system (λ c = 1310 nm) with an imaging range of 26.2 mm in the air, integrated with a high energy microsecond Er:YAG laser operating at 2.94 µm. We demonstrated that the self-healing characteristics of the BLB could reduce the imaging artifacts that may arise during real-time monitoring of laser ablation. Furthermore, the feasibility of using long-range OCT to monitor a deep laser-induced incision is demonstrated.

31 May 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
YBYakub. A. Bayhaqi
Yakub. A. Bayhaqi
AHArsham Hamidi
Arsham Hamidi
ANAlexander A. Navarini
Alexander A. Navarini
PCPhilippe C. Cattin
Philippe C. Cattin
FCFerda Canbaz
Ferda Canbaz
Azhar ZamAzhar Zam
Azhar Zam
This article presents a real-time noninvasive method for detecting bone and bone marrow in laser osteotomy. This is the first optical coherence tomography (OCT) implementation as an online feedback system for laser osteotomy. A deep-learning model has been trained to identify tissue types during laser ablation with a test accuracy of 96.28 %. For the hole ablation experiments, the average maximum depth of perforation and volume loss was 0.216 mm and 0.077 mm3, respectively. The contactless nature of OCT with the reported performance shows that it is becoming more feasible to utilize it as a real-time feedback system for laser osteotomy.

11 May 2024 in Ophthalmology Retina
Verified
Journal Article
Closed access
SBSpencer S. Burt
Spencer S. Burt
MWMani Woodward
Mani Woodward
SNShuibin Ni
Shuibin Ni
JJJohn Jackson
John Jackson
ACAaron S. Coyner
Aaron S. Coyner
JCJ. Peter Campbell
J. Peter Campbell

23 October 2023 in Lasers in Surgery and Medicine
Verified
Journal Article
Open access
AHArsham Hamidi
Arsham Hamidi
YBYakub A. Bayhaqi
Yakub A. Bayhaqi
Sandra DrusováSandra Drusová
Sandra Drusová
Alexander NavariniAlexander Navarini
Alexander Navarini
PCPhilippe C. Cattin
Philippe C. Cattin
Azhar ZamAzhar Zam
Azhar Zam
Objectives: The study aimed to improve the safety and accuracy of laser osteotomy (bone surgery) by integrating optical feedback systems with an Er:YAG laser. Optical feedback consists of a real‐time visual feedback system that monitors and controls the depth of laser‐induced cuts and a tissue sensor differentiating tissue types based on their chemical composition. The developed multimodal feedback systems demonstrated the potential to enhance the safety and accuracy of laser surgery.Materials and Methods: The proposed method utilizes a laser‐induced breakdown spectroscopy (LIBS) system and long‐range Bessel‐like beam optical coherence tomography (OCT) for tissue‐specific laser surgery. The LIBS system detects tissue types by analyzing the plasma generated on the tissue by a nanosecond Nd:YAG laser, while OCT provides real‐time monitoring and control of the laser‐induced cut depth. The OCT system operates at a wavelength of 1288 ± 30 nm and has an A‐scan rate of 104.17 kHz, enabling accurate depth control. Optical shutters are used to facilitate the integration of these multimodal feedback systems.Results: The proposed system was tested on five specimens of pig femur bone to evaluate its functionality. Tissue differentiation and visual depth feedback were used to achieve high precision both on the surface and in‐depth. The results showed successful real‐time tissue differentiation and visualization without any visible thermal damage or carbonization. The accuracy of the tissue differentiation was evaluated, with a mean absolute error of 330.4 μm and a standard deviation of ±248.9 μm, indicating that bone ablation was typically stopped before reaching the bone marrow. The depth control of the laser cut had a mean accuracy of 65.9 μm with a standard deviation of ±45 μm, demonstrating the system's ability to achieve the pre‐planned cutting depth.Conclusion: The integrated approach of combining an ablative laser, visual feedback (OCT), and tissue sensor (LIBS) has significant potential for enhancing minimally invasive surgery and warrants further investigation and development.

20 August 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
SNShuibin Ni
Shuibin Ni
RNRingo Ng
Ringo Ng
DSDavid Sutter
David Sutter
YBYakub Bayhaqi
Yakub Bayhaqi
SOSusan Ostmo
Susan Ostmo
YJYifan Jian
Yifan Jian
We present a handheld, non-mydriatic optical coherence tomography (OCT) system engineered for panretinal imaging across both pediatric and adult patients. The prototype achieves a 140° visual angle, enabling detailed visualization from the posterior pole to the peripheral retina without the need for pharmacologic dilation or scleral depression. A customized optical design minimizes beam wander while maintaining diffraction-limited resolution throughout the field of view. The system employs a 400 kHz VCSEL light source, facilitating high-speed image acquisition along with an extended axial imaging range of 12 mm in air, sufficient to accommodate retinal curvature. This combination of optical and hardware enhancements allows for rapid and comprehensive retinal assessment in a variety of clinical environments. To date, the system has been used in 117 imaging sessions involving broad patient cohorts, including 32 premature infants in a neonatal intensive care unit, as well as pediatric and adult patients in outpatient settings. In these sessions, the system has consistently produced high-resolution en face OCT images, B-scans, and OCT angiography (OCTA), demonstrating strong potential for diagnosing and monitoring peripheral retinal pathologies. The handheld, non-mydriatic design supports flexible use at the bedside and in preoperative settings, offering particular advantages in pediatric ophthalmology where conventional imaging techniques may be impractical.