The microsecond Er:YAG pulsed laser with a wavelength of λ = 2.94 μm has been widely used in the medical field, particularly for ablating dental tissues. Since bone and dental tissues have similar compositions, consisting of mineralized and rigid structures, the Er:YAG laser represents a promising tool for laserosteotomy applications. In this study, we explored the use of the Er:YAG laser for deep bone ablation, in an attempt to optimize its performance and identify its limitations. Tissue irrigation and the laser settings were optimized independently. We propose an automated irrigation feedback system capable of recognizing the temperature of the tissue and delivering water accordingly. The irrigation system used consists of a thin 50 μm diameter water jet. The water jet was able to penetrate deep into the crater during ablation, with a laminar flow length of 15 cm, ensuring the irrigation of deeper layers unreachable by conventional spray systems. Once the irrigation was optimized, ablation was considered independently of the irrigation water. In this way, we could better understand and adjust the laser parameters to suit our needs. We obtained line cuts as deep as 21 mm without causing any visible thermal damage to the surrounding tissue. The automated experimental setup proposed here has the potential to support deeper and faster ablation in laserosteotomy applications.
A novel real-time and non-destructive method for differentiating soft from hard tissue in laser osteotomy has been introduced and tested in a closed-loop fashion. Two laser beams were combined: a low energy frequency-doubled nanosecond Nd:YAG for detecting the type of tissue, and a high energy microsecond Er:YAG for ablating bone. The working principle is based on adjusting the energy of the Nd:YAG laser until it is low enough to create a microplasma in the hard tissue only (different energies are required to create plasma in different tissue types). Analyzing the light emitted from the generated microplasma enables real-time feedback to a shutter that prevents the Er:YAG laser from ablating the soft tissue.
This work presents a long-range and extended depth-of-focus optical coherence tomography (OCT) system using a Bessel-like beam (BLB) as a visual feedback system during laser osteotomy. We used a swept-source OCT system (λc = 1310 nm) with an imaging range of 26.2 mm in the air, integrated with a high energy microsecond Er:YAG laser operating at 2.94 µm. We demonstrated that the self-healing characteristics of the BLB could reduce the imaging artifacts that may arise during real-time monitoring of laser ablation. Furthermore, the feasibility of using long-range OCT to monitor a deep laser-induced incision is demonstrated.
This article presents a real-time noninvasive method for detecting bone and bone marrow in laser osteotomy. This is the first optical coherence tomography (OCT) implementation as an online feedback system for laser osteotomy. A deep-learning model has been trained to identify tissue types during laser ablation with a test accuracy of 96.28 %. For the hole ablation experiments, the average maximum depth of perforation and volume loss was 0.216 mm and 0.077 mm3, respectively. The contactless nature of OCT with the reported performance shows that it is becoming more feasible to utilize it as a real-time feedback system for laser osteotomy.
Minimally invasive laser surgeries that require the use of a flexible endoscope (flexiscope) could benefit from high-energy nanosecond laser pulses delivered through fibers for real-time tissue characterization and phenotyping. The damage threshold of the fiber’s glass material limits the maximum amount of deliverable peak power. To transmit high-energy pulses without damaging the fiber material, large-diameter fibers are typically used, leading to a limited bending radius. Moreover, in a large-core fiber, self-focusing can damage the fiber even if the tip remains intact. In this work, we tested a fused-end fiber bundle combined with a beam shaper capable of delivering more than 20 MW (>100 mJ/5 ns). The fiber bundle was tested over more than eight hours of operation, with different bending radiuses down to 15 mm. The results demonstrate, to the best of our knowledge, the highest peak power delivered through a flexible fiber, for a frequency-doubled Q-switched Nd:YAG laser.