Hildegard Tanner

Dr. Hildegard Tanner

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2009 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
HTHildegard Tanner
Hildegard Tanner
GHGerhard Hindricks
Gerhard Hindricks
MVMarius Volkmer
Marius Volkmer
SFSteve Furniss
Steve Furniss
VKVolker Kühlkamp
Volker Kühlkamp
HKHans Kottkamp
Hans Kottkamp

28 December 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
TKThomas Kueffer
Thomas Kueffer
HTHildegard Tanner
Hildegard Tanner
AMAntonio Madaffari
Antonio Madaffari
JSJens Seiler
Jens Seiler
AHAndreas Haeberlin
Andreas Haeberlin
LRLaurent Roten
Laurent Roten
Aims: The left atrial posterior wall is a potential ablation target in patients with recurrent atrial fibrillation despite durable pulmonary vein isolation or in patients with roof-dependent atrial tachycardia (AT). Pulsed-field ablation (PFA) offers efficient and safe posterior wall ablation (PWA), but available data are scarce. Methods and results: Consecutive patients undergoing PWA using PFA were included. Posterior wall ablation was performed using a pentaspline PFA catheter and verified by 3D-electroanatomical mapping. Follow-up was performed using 7-day Holter ECGs 3, 6, and 12 months after ablation. Recurrence of any atrial arrhythmia lasting more than 30 s was defined as failure. Lesion durability was assessed during redo procedures. Posterior wall ablation was performed in 215 patients (70% males, median age 70 [IQR 61–75] years, 67% redo procedures) and was successful in all patients (100%) by applying a median of 36 (IQR 32–44) PFA lesions. Severe adverse events were cardiac tamponade and vascular access complication in one patient each (0.9%). Median follow-up was 7.3 (IQR 5.0–11.8) months. One-year arrhythmia-free outcome in Kaplan–Meier analysis was 53%. A redo procedure was performed in 26 patients (12%) after a median of 6.9 (IQR 2.4–11) months and showed durable PWA in 22 patients (85%) with only minor lesion regression. Among four patients with posterior wall reconnection, three (75%) presented with roof-dependent AT. Conclusion: Posterior wall ablation with this pentaspline PFA catheter can be safely and efficiently performed with a high durability observed during redo procedures. The added value of durable PWA for the treatment of atrial fibrillation remains to be evaluated.

1 October 2022 in Radiology
Verified
Journal Article
Closed access
AHAdrian Thomas Huber
Adrian Thomas Huber
SFSeverin Fankhauser
Severin Fankhauser
LCLaurève Chollet
Laurève Chollet
SWSeverin Wittmer
Severin Wittmer
ALAnna Lam
Anna Lam
TRTobias Reichlin
Tobias Reichlin
Left atrial enhancing epicardial adipose tissue at preprocedural cardiac CT allowed for the identification of patients who were at high risk for atrial fibrillation recurrence after atrial fibrilla... Background The association of epicardial adipose tissue (EAT) and its metabolic activity with atrial fibrillation (AF) is an area of active investigation. Left atrial (LA) enhancing EAT (e-EAT) at ...

7 June 2022 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
AHAndreas Haeberlin
Andreas Haeberlin
JBJoanna Bartkowiak
Joanna Bartkowiak
NBNicolas Brugger
Nicolas Brugger
HTHildegard Tanner
Hildegard Tanner
EWElaine Wan
Elaine Wan
TRTobias Reichlin
Tobias Reichlin
Introduction: Conventional transvenous pacemaker leads may interfere with the tricuspid valve leaflets, tendinous chords, and papillary muscles, resulting in significant tricuspid valve regurgitation (TR). Leadless pacemakers (LLPMs) theoretically cause less mechanical interference with the tricuspid valve apparatus. However, data on TR after LLPM implantation are sparse and conflicting. Our goal was to investigate the prevalence of significant TR before and after LLPM implantation.Methods: Patients who received a leadless LLPM (Micra™ TPS, Medtronic) between May 2016 and May 2021 at our center were included in this observational study if they had at least a pre‐ and postinterventional echocardiogram (TTE). The evolution of TR severity was assessed. Following a systematic literature review on TR evolution after implantation of a LLPM, data were pooled in a random‐effects meta‐analysis.Results: We included 69 patients (median age 78 years [interquartile range (IQR) 72–84 years], 26% women). Follow‐up duration between baseline and follow‐up TTE was 11.4 months (IQR 3.5–20.1 months). At follow‐up, overall TR severity was not different compared to baseline (p = .49). Six patients (9%) had new significant TR during follow‐up after LLPM implantation, whereas TR severity improved in seven patients (10%). In the systematic review, we identified seven additional articles that investigated the prevalence of significant TR after LLPM implantation. The meta‐analysis based on 297 patients failed to show a difference in significant TR before and after LLPM implantation (risk ratio 1.22, 95% confidence interval 0.97–1.53, p = .11).Conclusion: To date, there is no substantial evidence for a significant change in TR after implantation of a LLPM.

14 June 2022 in EP Europace
Verified
Journal Article
Open access
TKThomas Kueffer
Thomas Kueffer
SBSamuel Baldinger
Samuel Baldinger
HSHelge Servatius
Helge Servatius
AMAntonio Madaffari
Antonio Madaffari
JSJens Seiler
Jens Seiler
TRTobias Reichlin
Tobias Reichlin
Aims: To validate the performance of a multipolar pulsed-field ablation (PFA) catheter compared to a standard pentaspline 3D-mapping catheter for endpoint assessment of pulmonary vein isolation (PVI). PFA for PVI using single-shot devices combines the benefits of high procedural efficacy and safety. A newly available multipolar PFA catheter allows real-time recording of pulmonary vein (PV) signals during PVI. Methods and results: Patients undergoing first PVI using PFA with the standard ablation protocol (eight applications per PV) were studied. Entrance and exit block (10 V/2 ms) were assessed using the PFA catheter. Subsequently, a high-density 3D electroanatomical bipolar voltage map (3D-EAM) was constructed using a standard pentaspline 3D-mapping catheter. Additional PFA applications were delivered only after confirmation of residual PV connection by 3D-EAM. In 56 patients, 213 PVs were targeted for ablation. Acute PVI was achieved in 100% of PVs: in 199/213 (93%) PVs with the standard ablation protocol alone and in the remaining 14 PVs after additional PFA applications. The accuracy of PV assessment with the PFA catheter after the standard ablation protocol was 91% (194/213 veins). In 5/213 (2.3%) PVs, the PFA catheter incorrectly indicated PV-isolation. In 14/213 (6.6%), the PFA catheter incorrectly indicated residual PV-conduction due to high-output pace-capture. Lowering the output to 5 V/1 ms reduced this observation to 0.9% (2/213) and increased the overall accuracy to 97% (206/213). Conclusion: A novel multipolar PFA catheter allows reliable endpoint assessment for PVI. Due to its design, far-field sensing and high-output pace-capture can occur. Lowering the pacing output increases the accuracy from 91 to 97%.

9 December 2018 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
LBLukas Bereuter
Lukas Bereuter
TKTimon Kuenzle
Timon Kuenzle
TNThomas Niederhauser
Thomas Niederhauser
MKMartin Kucera
Martin Kucera
Dominik ObristDominik Obrist
Dominik Obrist
AHAndreas Haeberlin
Andreas Haeberlin
Objective: A new generation of leadless cardiac pacemakers effectively overcomes the main limitations of conventional devices, but only offer single-chamber pacing, although dual-chamber or multisite pacing is highly desirable for most patients. The combination of several leadless pacemakers could facilitate a leadless multisite pacemaker but requires an energy-efficient wireless communication for device synchronization. This study investigates the characteristics of conductive intracardiac communication between leadless pacemakers to provide a basis for future designs of leadless multisite pacemaker systems. Methods: Signal propagation and impedance behavior of blood and heart tissue were examined by in vitro and in vivo measurements on domestic pig hearts and by finite-element simulations in the frequency range of 1 kHz to 1 MHz. Results: A better signal transmission was obtained for frequencies higher than 10 kHz. The influence of a variety of practical parameters on signal transmission could be identified. A larger distance between pacemakers increases signal attenuation. A better signal transmission is obtained through larger inter-electrode distances and a larger electrode surface area. Furthermore, the influence of pacemaker encapsulation and relative device orientation was assessed. Conclusion: This study suggests that conductive intracardiac communication is well suited to be incorporated in leadless pacemakers. It potentially offers very low power consumption using low communication frequencies. Significance: The presented technique enables highly desired leadless multisite pacing in near future.