Gaohui He

Dr. Gaohui He


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2024 in Coatings
Verified
Journal Article
Open access
PDF file
LCLiang Cao
Liang Cao
RXRui Xi
Rui Xi
CZChen Zhou
Chen Zhou
GHGaohui He
Gaohui He
FYFeng Yang
Feng Yang
He LiHe Li
He Li
Enhancing the energy storage properties of dielectric polymer capacitor films through composite materials has gained widespread recognition. Among the various strategies for improving dielectric materials, nanoscale coatings that create structurally controlled multiphase polymeric films have shown great promise. This approach has garnered considerable attention in recent years due to its effectiveness. This review examines surface-coated polymer composites used for dielectric energy storage, discussing their dielectric properties, behaviors, and the underlying physical mechanisms involved in energy storage. The review thoroughly examines the fabrication methods for nanoscale coatings and the selection of coating materials. It also explores the latest advancements in the rational design and control of interfaces in organic–inorganic, organic–organic, and heterogeneous multiphase structures. Additionally, the review delves into the structure–property relationships between different interfacial phases and various interface structures, analyzing how nanoscale coatings the impact dielectric constant, breakdown strength, conduction and charge transport mechanisms, energy density and efficiency, thermal stability, and electrothermal durability of polymeric capacitor films. Moreover, the review summarizes relevant simulation methods and offers computational insights. The potential practical applications and characteristics of such nanoscale coating techniques are discussed, along with the existing challenges and practical limitations. Finally, the review concludes with a summary and outlook, highlighting potential research directions in this rapidly evolving field.

16 December 2024 in Energies
Verified
Journal Article
Open access
PDF file
DXDexin Xie
Dexin Xie
ZQZhen Qin
Zhen Qin
SXShian Xie
Shian Xie
JJJian Jiang
Jian Jiang
FBFeng Bai
Feng Bai
GHGaohui He
Gaohui He
The presence of alternating current (AC) resistance in overhead conductors contributes to additional energy losses during electrical energy transmission and affects the current-carrying capacity of the lines. However, a standardized measurement method for AC resistance remains unavailable. This paper presents the design of an experimental platform for measuring the AC resistance of conductors using an electrical measurement approach in conjunction with the least squares method. In the experiments, data were collected for four conductors, including current, AC resistance, and temperature. The study analyzes the relationships among the AC resistance of the conductors, their temperature, and the AC/DC resistance ratio as the current varies. The results from measuring the AC/DC resistance ratio indicate that the platform is effective for AC resistance measurement and can serve as a valuable reference for evaluating the AC losses of existing line conductors.

30 October 2024 in Frontiers in Chemistry
Verified
Journal Article
Open access
PDF file
LCLiang Cao
Liang Cao
RWRui Wu
Rui Wu
HXHong Xiang
Hong Xiang
XWXiaodong Wu
Xiaodong Wu
XHXiaoyan Hu
Xiaoyan Hu
YGYingang Gui
Yingang Gui
Flexible pressure sensors applied in wearable detection often face challenges, such as low sensitivity, large device size, poor flexibility, and long response time. This study aims to design and develop high-performance pressure-sensitive materials for wearable human detection applications. Using a sensitive layer composite and microstructural design, rGO/Fe nanowires (NWs) composites were proposed as the pressure-sensitive material. This approach yields a compact sensor with high flexibility, good mechanical properties, and excellent sensing performance. Firstly, rGO/Fe NWs composites were prepared by the Hummers method and an in situ reduction technique under a magnetic field. Secondly, the structural design, component construction, and sensing mechanism of the sensors were thoroughly investigated. Finally, the performance of the flexible pressure sensor was tested, and its application in the wearable field was explored. The results demonstrate that the sensor exhibits excellent performance with a good response to both large and small pressures within the range of 0–30 kPa, providing an effective method for wearable human health detection.

7 January 2025 in Processes
Verified
Journal Article
Open access
PDF file
JZJunlong Zhou
Junlong Zhou
CTChao Tang
Chao Tang
MZMaolin Zhu
Maolin Zhu
WCWenchao Chen
Wenchao Chen
HYHongchun Yang
Hongchun Yang
GHGaohui He
Gaohui He
During deicing operations on transmission lines, the cutting forces generated by the milling cutter of a deicing robot exert significant reaction forces on the robot body. Excessive cutting forces can compromise the robot’s locomotion stability and deicing performance. This study introduces an optimization of the traditional straight-plate milling cutter by designing two new types of deicing milling cutters: oblique-cut and straight-cut milling cutters. The effects of cutter geometry, milling speed, and feed rate on cutting forces were systematically investigated using finite element simulations. A deicing test platform was constructed to validate the simulation results. The findings indicate that the cutting force hierarchy among the three designs is as follows: straight-plate > oblique-cut > straight-cut. Notably, the straight-cut milling cutter reduces cutting forces by 16–33% compared with the traditional straight-plate cutter. Furthermore, higher milling speeds and faster feed rates along the transmission line increase cutting forces. These studies provide valuable guidance for optimizing milling cutter designs in deicing robots.

12 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
RXRui Xi
Rui Xi
QJQiyang Jiang
Qiyang Jiang
LCLiang Cao
Liang Cao
CLChuping Li
Chuping Li
JHJiaxun He
Jiaxun He
CTChao Tang
Chao Tang
Moisture has been a crucial problem during the operation of cable systems. When we are faced with polypropylene (PP)-based insulation for the development of cable systems, there are few reports on the effects of water intrusion on the electrical performances of PP. In this study, the water absorption characteristics of isotactic PP (iPP) and atactic PP (aPP), as well as their effects on volume resistivity and relative permittivity, were investigated. The structure evolution during the water absorption process of the two PPs was also compared via infrared spectra and X-ray diffraction analyses. The results show that both of the two PPs show a saturation of water absorption at ~216 h, even though there are structural differences. And water intrusion into bulk could increase the interplanar spacing of iPP while decreasing the interplanar spacing of aPP. Moreover, with the increase in water absorption, the volume resistivity of the two PPs show a decreasing trend while the relative permittivity presents an increasing behavior, which shows an almost linear correlation.

24 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
JYJianbo Yu
Jianbo Yu
CWChangqing Wu
Changqing Wu
HHHao Huang
Hao Huang
DXDexin Xie
Dexin Xie
FQFeixiang Qin
Feixiang Qin
GHGaohui He
Gaohui He
In overhead wire transmission systems, the presence of AC resistance results in increased energy dissipation, adversely affecting the lines’ capacity to conduct current. This paper employs a finite element aluminum conductor steel-reinforced (ACSR) model, combined with electrical measurement techniques, to investigate AC resistance. By applying varying levels of AC current, the model is employed to determine the AC resistance which closely aligns with theoretical values estimated using the Morgan algorithm. The trends observed in the parameters are consistent, thereby validating the accuracy of the model. Following simulations and analyses regarding both AC resistance and temperature variations within the conductors—and incorporating empirical measurement results—it is demonstrated that, when environmental factors are not considered, any increase in the conductor temperature can be integrated into a revised model. This updated model is subsequently compared against test results obtained from an experimental platform; the findings confirm that the estimation errors remain within an acceptable range. Overall, this simulation model serves as a valuable reference for assessing AC losses in existing conductors, as well as contributing to reduced experimental costs while mitigating the associated risks and challenges. In summary, this simulation model serves as an essential reference for assessing AC losses in current conductors and aids in reducing experimental costs while addressing the associated risks and challenges.