Lei Lei

Prof. Lei Lei

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2025 in Fire
Verified
Journal Article
Open access
PDF file
YXYunfei Xia
Yunfei Xia
LLLei Lei
Lei Lei
SZSiyuan Zeng
Siyuan Zeng
DLDa Li
Da Li
WCWei Cai
Wei Cai
YYYujie Yin
Yujie Yin
Point-type smoke fire detectors have become one of the most commonly used technical means in the fire detection systems of ancient buildings. However, in practical applications, their performance is easily affected by special environmental interference factors. Therefore, in this study, a full-scale experimental scene of an ancient building with a typical flush gable roof structure was taken as the research object, and the differential influence laws of three typical interference sources, namely wind speed, water vapor, and incense burning, on the response times of point-type smoke detectors were quantified. Moreover, the prediction models of the alarm time of the detectors under the three interference conditions were established. The results indicate the following: (1) Within the range of experimental conditions, there is a quantitative relationship between the detector response delay and the type of interference source: the delay time shows a nonlinear positive correlation with the wind speed/water vapor interference gradient, while it exhibits a threshold unimodal change characteristic with the burning incense interference gradient; (2) under interference conditions, the detector response delay varies depending on the type of fire source: the detector has the best detection stability for smoldering smoke from a smoke cake, while it has the lowest detection sensitivity for smoldering smoke from a cotton rope. Moreover, the influence of wind speed interference is weaker than that of water vapor or smoke from burning incense, and the difference is the greatest in the wood block smoldering condition. (3) Construct a detector alarm time prediction model under three types of interference conditions, where the wind speed, water vapor, and burning incense interference conditions conform to third-order polynomial functions, Sigmoid functions, and fourth-order polynomial functions, respectively.

17 January 2025 in Fire
Verified
Journal Article
Open access
PDF file
YXYunfei Xia
Yunfei Xia
QGQingming Guo
Qingming Guo
LLLei Lei
Lei Lei
JWJiong Wu
Jiong Wu
XSXin Su
Xin Su
JWJianxin Wu
Jianxin Wu
A new safety risk assessment model for battery pack production processes was developed using the DEMATEL-ANP method to analyze the impact and complex relationships of risk-influencing factors. Initially, five major risk-influencing factors were identified, leading to the construction of a 15-factor indicator system. Through the DEMATEL method, these factors were categorized into cause and result factors. Subsequently, by combining the DEMATEL and ANP methods, key risk-influencing factors were identified by comparing ANP weights with hybrid weights adjusted through the DEMATEL-ANP method. Finally, integrating the DEMATEL-ANP method with the fuzzy comprehensive evaluation method allowed us to assess the overall fire safety risk level. Our findings highlighted “hazards in the test process” and “fire hazards” as critical risk factors needing control and elimination in the highly hazardous battery pack production process. This method offers dynamic evaluation and valuable insights for safety management in battery pack production.

19 November 2024 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
LLLei Lei
Lei Lei
ZWZeyu Wang
Zeyu Wang
ZLZihao Liang
Zihao Liang

20 February 2026 in Sensors
Verified
Journal Article
Open access
PDF file
CLChen Li
Chen Li
MWMinghan Wang
Minghan Wang
LLLei Lei
Lei Lei
HLHonghui Liu
Honghui Liu
KGKaiyin Gao
Kaiyin Gao
ZWZuoyi Wang
Zuoyi Wang
Fire detection in ancient architecture presents significant challenges due to complex scenes and unique structural characteristics. Traditional detection methods often demonstrate limitations when addressing the specific structural idiosyncrasies of individual ancient buildings and the overlapping occlusion prevalent in architectural complexes. This paper proposes YOLO-AR, a novel fire detection algorithm based on an improved YOLOv8 framework. By embedding the Convolutional Block Attention Module (CBAM) at the end of the backbone network, the algorithm enhances its capability to capture key features of flames and smoke. Furthermore, the Repulsion Loss function is introduced to explicitly optimize bounding box localization accuracy in occluded and dense scenarios. Experiments conducted on a self-constructed ancient architecture dataset comprising 15,847 images demonstrate that YOLO-AR outperforms mainstream comparative algorithms in terms of Precision, Recall, and mean Average Precision (mAP). Specifically, the detection precision reached 90.7%, and the recall rate improved to 89.7%. This study provides an efficient and reliable visual detection solution for early warning systems in ancient architecture, offering significant value for cultural heritage preservation.

8 December 2025 in Electronics
Verified
Journal Article
Open access
PDF file
SZSiyuan Zeng
Siyuan Zeng
LLLei Lei
Lei Lei
GTGang Tian
Gang Tian
YLYimin Li
Yimin Li
JWJianhua Wang
Jianhua Wang
Arc fault detection is a key technology for preventing electrical fires. However, existing research has primarily focused on series connections, with insufficient attention paid to parallel load conditions, which are prevalent in real-world residential electricity usage. In accordance with the UL 1699 and IEC 62606 standards, this study established an experimental platform for arc faults, incorporating seven single loads (categorized into four types) and nine multi-load combinations. A systematic analysis of the differences in time–frequency characteristics under different connection modes was conducted. Time-domain and frequency-domain analyses revealed that under parallel connection the dispersion of arc fault time-domain characteristics decreases by more than 50% and the fundamental frequency component increases significantly. For parallel multi-load scenarios, the fundamental component of resistive combinations can reach 90%, while the frequency variance of inductive combinations can be as high as 400,000. By elucidating the time–frequency domain characteristics of parallel arc faults, this study proposes an optimized feature parameter analysis scheme for electrical fire monitoring systems. Based on this, this paper proposes an arc fault detection method using the Dual-Channel Convolutional Neural Network (DCNN). The method achieves 97.09% recognition accuracy for arc faults with different connection modes. Comparative experiments with other models and ablation studies show that the model attains 98.52% detection accuracy, verifying the effectiveness of the proposed method. This approach can significantly improve the accuracy of arc fault detection in multi-load environments, thereby enabling early warning of electrical circuit faults and potential fire hazards.

2 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
XLXinyi Li
Xinyi Li
XZXinrui Zhang
Xinrui Zhang
LLLei Lei
Lei Lei
With the development of IoT, RFID technology has become a core enabler for ubiquitous sensing. Traditional fire protection systems suffer from information silos, delayed responses, and inaccurate positioning. Passive IoT and integrated communication-sensing technologies address these issues by enabling cost-effective, power-free, and multi-dimensional sensing via RFID tags (e.g., monitoring equipment status, channel blockages). However, unreliable channels and unknown tag interference hinder data reliability. This paper proposes a layered cross-system platform fusing RFID, WSN, and advanced algorithms to integrate multi-source data. It enhances sensing robustness and realizes intelligent functions like risk early warning, resource scheduling, and dynamic evacuation routing, boosting fire safety intelligence and emergency response efficiency.