A new safety risk assessment model for battery pack production processes was developed using the DEMATEL-ANP method to analyze the impact and complex relationships of risk-influencing factors. Initially, five major risk-influencing factors were identified, leading to the construction of a 15-factor indicator system. Through the DEMATEL method, these factors were categorized into cause and result factors. Subsequently, by combining the DEMATEL and ANP methods, key risk-influencing factors were identified by comparing ANP weights with hybrid weights adjusted through the DEMATEL-ANP method. Finally, integrating the DEMATEL-ANP method with the fuzzy comprehensive evaluation method allowed us to assess the overall fire safety risk level. Our findings highlighted “hazards in the test process” and “fire hazards” as critical risk factors needing control and elimination in the highly hazardous battery pack production process. This method offers dynamic evaluation and valuable insights for safety management in battery pack production.
Point-type smoke fire detectors have become one of the most commonly used technical means in the fire detection systems of ancient buildings. However, in practical applications, their performance is easily affected by special environmental interference factors. Therefore, in this study, a full-scale experimental scene of an ancient building with a typical flush gable roof structure was taken as the research object, and the differential influence laws of three typical interference sources, namely wind speed, water vapor, and incense burning, on the response times of point-type smoke detectors were quantified. Moreover, the prediction models of the alarm time of the detectors under the three interference conditions were established. The results indicate the following: (1) Within the range of experimental conditions, there is a quantitative relationship between the detector response delay and the type of interference source: the delay time shows a nonlinear positive correlation with the wind speed/water vapor interference gradient, while it exhibits a threshold unimodal change characteristic with the burning incense interference gradient; (2) under interference conditions, the detector response delay varies depending on the type of fire source: the detector has the best detection stability for smoldering smoke from a smoke cake, while it has the lowest detection sensitivity for smoldering smoke from a cotton rope. Moreover, the influence of wind speed interference is weaker than that of water vapor or smoke from burning incense, and the difference is the greatest in the wood block smoldering condition. (3) Construct a detector alarm time prediction model under three types of interference conditions, where the wind speed, water vapor, and burning incense interference conditions conform to third-order polynomial functions, Sigmoid functions, and fourth-order polynomial functions, respectively.