Ahmed Salim

Dr. Ahmed Salim

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2016 in Sensors
Verified
Journal Article
Open access
PDF file
ASAhmed Salim
Ahmed Salim
Sungjoon LimSungjoon Lim
Sungjoon Lim
In this paper, a complementary split-ring resonator (CSRR)-loaded patch is proposed as a microfluidic ethanol chemical sensor. The primary objective of this chemical sensor is to detect ethanol’s concentration. First, two tightly coupled concentric CSRRs loaded on a patch are realized on a Rogers RT/Duroid 5870 substrate, and then a microfluidic channel engraved on polydimethylsiloxane (PDMS) is integrated for ethanol chemical sensor applications. The resonant frequency of the structure before loading the microfluidic channel is 4.72 GHz. After loading the microfluidic channel, the 550 MHz shift in the resonant frequency is ascribed to the dielectric perturbation phenomenon when the ethanol concentration is varied from 0% to 100%. In order to assess the sensitivity range of our proposed sensor, various concentrations of ethanol are tested and analyzed. Our proposed sensor exhibits repeatability and successfully detects 10% ethanol as verified by the measurement set-up. It has created headway to a miniaturized, non-contact, low-cost, reliable, reusable, and easily fabricated design using extremely small liquid volumes.

15 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ASAhmed Salim
Ahmed Salim
Sungjoon LimSungjoon Lim
Sungjoon Lim
Metamaterial elements/arrays exhibit a sensitive response to fluids yet with a small footprint, therefore, they have been an attractive choice to realize various sensing devices when integrated with microfluidic technology. Micro-channels made from inexpensive biocompatible materials avoid any contamination from environment and require only microliter–nanoliter sample for sensing. Simple design, easy fabrication process, light weight prototype, and instant measurements are advantages as compared to conventional (optical, electrochemical and biological) sensing systems. Inkjet-printed flexible sensors find their utilization in rapidly growing wearable electronics and health-monitoring flexible devices. Adequate sensitivity and repeatability of these low profile microfluidic sensors make them a potential candidate for point-of-care testing which novice patients can use reliably. Aside from degraded sensitivity and lack of selectivity in all practical microwave chemical sensors, they require an instrument, such as vector network analyzer for measurements and not readily available as a self-sustained portable sensor. This review article presents state-of-the-art metamaterial inspired microfluidic bio/chemical sensors (passive devices ranging from gigahertz to terahertz range) with an emphasis on metamaterial sensing circuit and microfluidic detection. We also highlight challenges and strategies to cope these issues which set future directions.

10 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
ASAhmed Salim
Ahmed Salim
Sungjoon LimSungjoon Lim
Sungjoon Lim
Inkjet printing is an advanced printing technology that has been used to develop conducting layers, interconnects and other features on a variety of substrates. It is an additive manufacturing process that offers cost-effective, lightweight designs and simplifies the fabrication process with little effort. There is hardly sufficient research on tactile sensors and inkjet printing. Advancements in materials science and inkjet printing greatly facilitate the realization of sophisticated tactile sensors. Starting from the concept of capacitive sensing, a brief comparison of printing techniques, the essential requirements of inkjet-printing and the attractive features of state-of-the art inkjet-printed tactile sensors developed on diverse substrates (paper, polymer, glass and textile) are presented in this comprehensive review. Recent trends in inkjet-printed wearable/flexible and foldable tactile sensors are evaluated, paving the way for future research.

18 August 2020 in IEEE Access
Verified
Journal Article
Open access
ASAhmed Salim
Ahmed Salim
Aqeel Hussain NaqviAqeel Hussain Naqvi
Aqeel Hussain Naqvi
DPDuc Anh Pham
Duc Anh Pham
Sungjoon LimSungjoon Lim
Sungjoon Lim
Single-resonance-based radio frequency (RF) resonators cannot detect multiple cracks simultaneously nor localize the position of a crack. To address these drawbacks, we propose a complementary split-ring resonator (CSRR)-loaded array. In this array, there are four channels and each channel consists of three CSRRs, forming a 4×3 sensing array that is developed in the ground plane of a microstrip line using a low-cost FR4 substrate. A voltage-controlled oscillator (VCO) generates three discrete frequencies: 1.88 GHz, 2.60 GHz, and 3.61 GHz to each channel, which is sequentially selected using a single-pole four-throw (SP4T) switch. The transmitted RF signals are converted into the DC voltage levels and are interpreted by a microcontroller. Aluminum sheets with cracks embedded in the surface are used to demonstrate the detection of cracks of various shapes, sizes and locations/orientations (horizontal, diagonal, and vertical) with simulations and measurements. The detection of the minimum detectable crack (Wc×Lc×Dc = 1 mm × 10 mm × 0.1 mm) is experimentally verified. Full-length longer cracks (Lc = 100 mm) are also detected using our proposed detection system with the SP4T switch in addition to our proposed algorithm that scans the CSRRs of each selected channel.

12 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ASAhmed Salim
Ahmed Salim
SGSaptarshi Ghosh
Saptarshi Ghosh
Sungjoon LimSungjoon Lim
Sungjoon Lim
In this paper, a microwave cavity resonator is presented for chemical sensing applications. The proposed resonator is comprised of a three dimensional (3D) split-ring resonator (SRR) residing in an external cavity and capacitively coupled by a pair of coaxial probes. 3D-printing technology with polylactic acid (PLA) filament is used to build the 3D SRR and cavity. Then, the surfaces of the SRR and the inside walls of cavity are silver-coated. The novelty of our proposed structure is its light weight and inexpensive design, owing to the utilization of low density and low-cost PLA. A Teflon tube is passed through the split-gap of the SRR so that it is parallel to the applied electric field. With an empty tube, the resonance frequency of the structure is measured at 2.56 GHz with an insertion loss of 13.6 dB and quality factor (Q) of 75. A frequency shift of 205 MHz with respect to the empty channel was measured when deionized water (DIW) was injected into the tube. Using volume occupied by the structure, the weight of the proposed microwave resonator is estimated as 22.8 g which is significantly lighter than any metallic structure of comparable size.

7 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ASAhmed Salim
Ahmed Salim
MMMuhammad Usman Memon
Muhammad Usman Memon
Sungjoon LimSungjoon Lim
Sungjoon Lim
Microwave resonators working as sensors can detect only a single analyte at a time. To address this issue, a TE20-mode substrate-integrated waveguide (SIW) resonator is exploited, owing to its two distinct regions of high-intensity electric fields, which can be manipulated by loading two chemicals. Two microfluidic channels with unequal fluid-carrying capacities, engraved in a polydimethylsiloxane (PDMS) sheet, can perturb the symmetric electric fields even if loaded with the two extreme cases of dielectric [ethanol (E), deionized water (DI)] and [deionized water, ethanol]. The four layers of the sandwiched structure considered in this study consisted of a top conductive pattern and a bottom ground, both realized on a Rogers RT/Duroid 5880. PDMS-based channels attached with an adhesive serve as the middle layers. The TE20-mode SIW with empty channels resonates at 8.26 GHz and exhibits a −25 dB return loss with an unloaded quality factor of Q ≈ 28. We simultaneously load E and DI and demonstrate the detection of the four possible combinations: [E, DI], [DI, E], [E, E], and [DI, DI]. The performance of our proposed method showed increases in sensitivity (MHz/εr) of 7.5%, 216%, and 1170% compared with three previously existing multichannel microwave chemical sensors.