Thibault Marin

Dr. Thibault Marin

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YDYanis Djebra
Yanis Djebra
TMThibault Marin
Thibault Marin
PHPaul K. Han
Paul K. Han
IBIsabelle Bloch
Isabelle Bloch
GFGeorges El Fakhri
Georges El Fakhri
CMChao Ma
Chao Ma
The spatial resolution and temporal frame-rate of dynamic magnetic resonance imaging (MRI) can be improved by reconstructing images from sparsely sampled ${k}$ -space data with mathematical modeling of the underlying spatiotemporal signals. These models include sparsity models, linear subspace models, and non-linear manifold models. This work presents a novel linear tangent space alignment (LTSA) model-based framework that exploits the intrinsic low-dimensional manifold structure of dynamic images for accelerated dynamic MRI. The performance of the proposed method was evaluated and compared to state-of-the-art methods using numerical simulation studies as well as 2D and 3D in vivo cardiac imaging experiments. The proposed method achieved the best performance in image reconstruction among all the compared methods. The proposed method could prove useful for accelerating many MRI applications, including dynamic MRI, multi-parametric MRI, and MR spectroscopic imaging.

2 December 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
TMThibault Marin
Thibault Marin
YDYanis Djebra
Yanis Djebra
PHPaul K Han
Paul K Han
YCYanis Chemli
Yanis Chemli
IBIsabelle Bloch
Isabelle Bloch
CMChao Ma
Chao Ma
Image quality of positron emission tomography (PET) reconstructions is degraded by subject motion occurring during the acquisition. Magnetic resonance (MR)-based motion correction approaches have been studied for PET/MR scanners and have been successful at capturing regular motion patterns, when used in conjunction with surrogate signals (e.g. navigators) to detect motion. However, handling irregular respiratory motion and bulk motion remains challenging. In this work, we propose an MR-based motion correction method relying on subspace-based real-time MR imaging to estimate motion fields used to correct PET reconstructions. We take advantage of the low-rank characteristics of dynamic MR images to reconstruct high-resolution MR images at high frame rates from highly undersampled k-space data. Reconstructed dynamic MR images are used to determine motion phases for PET reconstruction and estimate phase-to-phase nonrigid motion fields able to capture complex motion patterns such as irregular respiratory and bulk motion. MR-derived binning and motion fields are used for PET reconstruction to generate motion-corrected PET images. The proposed method was evaluated on in vivo data with irregular motion patterns. MR reconstructions accurately captured motion, outperforming state-of-the-art dynamic MR reconstruction techniques. Evaluation of PET reconstructions demonstrated the benefits of the proposed method in terms of motion artifacts reduction, improving the contrast-to-noise ratio by up to a factor 3 and achieveing a target-to-background ratio up to 90% superior compared to standard/uncorrected methods. The proposed method can improve the image quality of motion-corrected PET reconstructions in clinical applications.

1 November 2016 in Progress in Quantum Electronics
Verified
Journal Article
Closed access
YZYue Zhuo
Yue Zhuo
JCJi Sun Choi
Ji Sun Choi
TMThibault Marin
Thibault Marin
HYHojeong Yu
Hojeong Yu
BHBrendan A. Harley
Brendan A. Harley
Brian CunninghamBrian Cunningham
Brian Cunningham

20 November 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
CMChao Ma
Chao Ma
PHPaul Kyu Han
Paul Kyu Han
YZYue Zhuo
Yue Zhuo
YDYanis Djebra
Yanis Djebra
TMThibault Marin
Thibault Marin
GFGeorges El Fakhri
Georges El Fakhri

6 September 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MOMatic Orehar
Matic Orehar
RDRok Dolenec
Rok Dolenec
GFGeorges El Fakhri
Georges El Fakhri
SKSamo Korpar
Samo Korpar
PKPeter Križan
Peter Križan
RPRok Pestotnik
Rok Pestotnik
In time-of-flight positron emission tomography (TOF-PET), a coincidence time resolution (CTR) below 100 ps reduces the angular coverage requirements and, thus, the geometric constraints of the scanner design. Among other possibilities, this opens the possibility of using flat-panel PET detectors. Such a design would be more cost-accessible and compact and allow for a higher degree of modularity than a conventional ring scanner. However, achieving adequate CTR is a considerable challenge and requires improvements at every level of detection. Based on recent results in the ongoing development of optimised TOF-PET photodetectors and electronics, we expect that within a few years, a CTR of about 75 ps will be be achievable at the system level. In this work, flat-panel scanners with four panels and various design parameters were simulated, assessed and compared to a reference scanner based on the Siemens Biograph Vision using NEMA NU 2-2018 metrics. Point sources were also simulated, and a method for evaluating spatial resolution that is more appropriate for flat-panel geometry is presented. We also studied the effects of crystal readout strategies, comparing single-crystal and module readout levels. The results demonstrate that with a CTR below 100 ps, a flat-panel scanner can achieve image quality comparable to that of a reference clinical scanner, with considerable savings in scintillator material.

25 February 2024 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
ENElie Najem
Elie Najem
TMThibault Marin
Thibault Marin
YZYue Zhuo
Yue Zhuo
RLRita Maria Lahoud
Rita Maria Lahoud
FTFei Tian
Fei Tian
GFGeorges El Fakhri
Georges El Fakhri