Misael Ruiz-Veloz

Dr. Misael Ruiz-Veloz


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2021 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
Misael Ruiz-VelozMisael Ruiz-Veloz
Misael Ruiz-Veloz
GMGeminiano Martinez-Ponce
Geminiano Martinez-Ponce
RFRafael I. Fernández-Ayala
Rafael I. Fernández-Ayala
RCRigoberto Castro-Beltrán
Rigoberto Castro-Beltrán
LPLUIS POLO-PARADA
LUIS POLO-PARADA
GGGerardo Gutiérrez-Juárez
Gerardo Gutiérrez-Juárez
When thermal and stress confinement conditions are satisfied, the propagation of laser-induced ultrasound (LIU) is governed by an inhomogeneous wave equation for pressure, and the laser temporal profile can be modeled by a Dirac delta distribution. If these conditions are not fulfilled, the coupled differential equations for temperature and pressure must be solved, considering a laser pulse with finite time-width. Here, an exact solution of the boundary value problem for the 1D-wave equation is obtained in both the frequency domain and the time domain. Since highly absorbent optical materials are out of the validity range of the confinement conditions, these are used as a numerical and experimental model. It is shown that the impulse-response model correctly predicts the time of flight of photoacoustic waves. However, when considering a laser pulse with finite time-width, the resultant theoretical amplitude of the LIU signal decays rapidly to zero, which is not observed in the experiment. To overcome this, we propose a thermal correction on the LIU source, defined typically as the optical penetration length, which imposes a redefinition of stress and thermal confinement in just one statement. Additionally, with the aim of comparing the corrected-theoretical results with the acquired electrical signals, the sensor and the oscilloscope were modeled as an RC circuit in parallel. It was found that the amplitude of the electrical signal was proportional to the difference of the LIU amplitudes at the faces of the sensor. It is demonstrated that even though the sensor impulse response is modeled as a Dirac delta distribution, this difference strongly affects the shape of the LIU electrical signals, hiding relevant information of the acoustic waves.

1 January 2023 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
Misael Ruiz-VelozMisael Ruiz-Veloz
Misael Ruiz-Veloz
GGGerardo Gutiérrez-Juárez
Gerardo Gutiérrez-Juárez
LPLUIS POLO-PARADA
LUIS POLO-PARADA
FCFrancisco Cortalezzi
Francisco Cortalezzi
DKDavid D. Kline
David D. Kline
CHCarlos Hidalgo-Valadez
Carlos Hidalgo-Valadez
This paper aims to implement a laser-induced ultrasound imaging reconstruction method based on the delay-and-sum beamforming through the synthetic aperture focusing technique (SAFT) for a circular scanning, performed with a tomograph that had one acoustic sensor and a system that rotates the sample around a fixed axis. The proposed method, called the Single-sensor Scanning Synthetic Aperture Focusing Technique, considers the size of the sensor and the detection procedure inside the SAFT's algebra. This image reconstruction method was evaluated numerically, using the Green function for the laser-induced ultrasound wave equation to generate a forward problem, and experimentally, using a solid object of polylactic acid, and a Sprague–Dawley rat heart located in a tissue-mimicking phantom. The resulting images were compared to those obtained from the time reversal and the conventional delay-and-sum reconstruction algorithms. The presented method removes the sidelobe artifacts and the comet tail sign, which produces a more distinguishable target on the image. In addition, the proposed method has a faster performance and lower computational load. The implementation of this method in photoacoustic microscopy techniques for image reconstruction is discussed.

21 July 2024 in Photonics
Verified
Journal Article
Open access
PDF file
MCMarco P. Colín-García
Marco P. Colín-García
Misael Ruiz-VelozMisael Ruiz-Veloz
Misael Ruiz-Veloz
LPLUIS POLO-PARADA
LUIS POLO-PARADA
RCRosalba Castañeda-Guzmán
Rosalba Castañeda-Guzmán
GGGerardo Gutiérrez-Juárez
Gerardo Gutiérrez-Juárez
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
This work compares photoacoustic images of a tooth by analyzing the signals generated with wavelengths 532 and 355 nm. This comparison addresses the differences in the optical properties of dental tissue for these wavelengths that affect the resulting photoacoustic images. A pulsed Nd:YAG laser was used to illuminate a complete extracted tooth sample, and 2D photoacoustic images (PAIs) were reconstructed using the single-sensor scanning synthetic aperture focusing technique (SSC-SAFT), which is a suitable method for our experimental system with forward detection mode. Signal comparison was conducted using sinogram, signal-to-noise ratio (SNR), root mean square (RMS), arrival time, maximum amplitude, and fast Fourier transform (FFT). PAI comparison utilized intensity profile, edge correlation, and image composition tools. The signal analysis revealed that at 532 nm, the signals exhibited longer decay time and a wider distribution of vibration frequencies due to higher laser pulse energy and greater optical penetration depth. Conversely, at 355 nm, the signals had shorter decay times and a lower frequency distribution, which was attributed to lower energy but improved optical absorption, resulting in reconstructed images with better sharpness and contour definition. This study contributes to the advancement of photoacoustic imaging technology in dentistry by providing insights that could optimize signal generation and image reconstruction for dental tissue.

20 August 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MCMarco P. Colín-García
Marco P. Colín-García
Misael Ruiz-VelozMisael Ruiz-Veloz
Misael Ruiz-Veloz
GGGerardo Gutiérrez-Juárez
Gerardo Gutiérrez-Juárez
GMGonzalo Montoya
Gonzalo Montoya
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
APArgelia Perez
Argelia Perez
Photoacoustic tomography (PAT), which combines optical absorption and ultrasonic detection, enables the monitoring of dehydration-driven structural changes in extracted teeth over time. In this proof-of-concept study, 2D photoacoustic images of a wisdom tooth were generated on the same scanning plane at days 0, 1, 3, 6, 10, 15, 21, and 28 post-extraction, using day 0 as the reference. Measurements were performed in forward-detection mode with a single ultrasound transducer and a 532 nm pulsed laser. For the comparative analysis of variations between images, four metrics were used: Pearson correlation coefficient, Structural Similarity Index (SSIM), Mean Squared Error (MSE), and Peak Signal-to-Noise Ratio (PSNR). Structural changes were also examined through radial intensity profiles extracted from each image. The results revealed marked differences in the central region, evidencing progressive structural and acoustic modifications within the tooth. The most significant change occurred on day 1, followed by small but consistent variations on subsequent days. These differences are associated with dehydration-induced changes in tissue density, which affect sound propagation. This study highlights the value of PAT for noninvasive monitoring of post-extraction dental changes, with implications for diagnosis, treatment guidance, and biomaterials research in dentistry.

27 May 2026 in Applied Physics A
Verified
Journal Article
Closed access
OMOrlando M Medina-Cázares
Orlando M Medina-Cázares
Misael Ruiz-VelozMisael Ruiz-Veloz
Misael Ruiz-Veloz
LELenin Escamilla
Lenin Escamilla
FGFrancisco J García-Rodríguez
Francisco J García-Rodríguez
LPLUIS POLO-PARADA
LUIS POLO-PARADA
GGGerardo Gutiérrez-Juárez
Gerardo Gutiérrez-Juárez