Absorbed radiation doses are essential in assessing the effects, e.g. safety and efficacy, of radiopharmaceutical therapy (RPT). Patient-specific absorbed dose calculations in the target or the organ at risk require multiple inputs. These include the number of disintegrations in the organ, i.e. the time-integrated activities (TIAs) of the organs, as well as other parameters describing the process of radiation energy deposition in the target tissue (i.e. mean energy per disintegration, radiation dose constants, etc). TIAs are then estimated by incorporating the area under the radiopharmaceutical's time-activity curve (TAC), which can be obtained by quantitative measurements of the biokinetics in the patient (typically based on imaging data such as planar scintigraphy, SPECT/CT, PET/CT, or blood and urine samples). The process of TAC determination/calculation for RPT generally depends on the user, e.g., the chosen number and schedule of measured time points, the selection of the fit function, the error model for the data and the fit algorithm. These decisions can strongly affect the final TIA values and thus the accuracy of calculated absorbed doses. Despite the high clinical importance of the TIA values, there is currently no consensus on processing time-activity data or even a clear understanding of the influence of uncertainties and variations in personalised RPT dosimetry related to user-dependent TAC calculation. As a first step towards minimising site-dependent variability in RPT dosimetry, this work provides an overview of quality assurance and uncertainty management considerations of the TIA estimation.
27 September 2018 in Contrast Media & Molecular Imaging
Background and Purpose. The accurate prediction of prognosis and pattern of failure is crucial for optimizing treatment strategies for patients with cancer, and early evidence suggests that image texture analysis has great potential in predicting outcome both in terms of local control and treatment toxicity. The aim of this study was to assess the value of pretreatment 18F-FDG PET texture analysis for the prediction of treatment failure in primary head and neck squamous cell carcinoma (HNSCC) treated with concurrent chemoradiation therapy. Methods. We performed a retrospective analysis of 90 patients diagnosed with primary HNSCC treated between January 2010 and June 2017 with concurrent chemo-radiotherapy. All patients underwent 18F-FDG PET/CT before treatment. 18F-FDG PET/CT texture features of the whole primary tumor were measured using an open-source texture analysis package. Least absolute shrinkage and selection operator (LASSO) was employed to select the features that are associated the most with clinical outcome, as progression-free survival and overall survival. We performed a univariate and multivariate analysis between all the relevant texture parameters and local failure, adjusting for age, sex, smoking, primary tumor site, and primary tumor stage. Harrell c-index was employed to score the predictive power of the multivariate cox regression models. Results. Twenty patients (22.2%) developed local failure, whereas the remaining 70 (77.8%) achieved durable local control. Multivariate analysis revealed that one feature, defined as low-intensity long-run emphasis (LILRE), was a significant predictor of outcome regardless of clinical variables (hazard ratio < 0.001, ).The multivariate model based on imaging biomarkers resulted superior in predicting local failure with a c-index of 0.76 against 0.65 of the model based on clinical variables alone. Conclusion. LILRE, evaluated on pretreatment 18F-FDG PET/CT, is associated with higher local failure in patients with HNSCC treated with chemoradiotherapy. Using texture analysis in addition to clinical variables may be useful in predicting local control.
In spite of the hazard due to the radiation exposure, preparation of 90Y- and 177Lu-labelled radiopharmaceuticals is still mainly performed using manual procedures. In the present study the performance of a commercial automatic synthesizer based on disposable cassettes for the labelling of 177Lu- and 90Y-DOTA-conjugated biomolecules (namely, DOTATOC and PSMA-617) was evaluated and compared to a manual and a semiautomated approach. The dose exposure of the operators was evaluated as well. More than 300 clinical preparations of both 90Y- and 177Lu-labelled radiopharmaceuticals have been performed using the three different methods. The mean radiochemical yields for 90Y-DOTATOC were %, %, and %, while for 177Lu-DOTATOC they were 98.3% ± 0.6, 90.8% ± 8.3, and % when manual, semiautomated, and automated approaches were used, respectively. The mean doses on the whole hands for yttrium-90 preparations were mSv/GBq, mSv/GBq, and mSv/GBq for manual, semiautomated, and automated synthesis, respectively, and for lutetium-177 preparations, they were mSv/GBq, mSv/GBq, and mSv/GBq, respectively. In conclusion, the automated approach guaranteed reliable and reproducible preparations of pharmaceutical grade therapeutic radiopharmaceuticals in a decent RCY. The radiation exposure of the operators remained comparable to the manual approach mainly due to the fact that a dedicated shielding was still not available for the system.
Peptide receptor radionuclide therapy (PRRT) is an effective MRT (molecular radiotherapy) treatment, which consists of multiple administrations of a radiopharmaceutical labelled with 177Lu or 90Y. Through sequential functional imaging a patient specific 3D dosimetry can be derived. Multiple scans should be previously co-registered to allow accurate absorbed dose calculations. The purpose of this study is to evaluate the impact of image registration algorithms on 3D absorbed dose calculation. A cohort of patients was extracted from the database of a clinical trial in PRRT. They were administered with a single administration of 177Lu-DOTATOC. All patients underwent 5 SPECT/CT sequential scans at 1 h, 4 h, 24 h, 40 h, 70 h post-injection that were subsequently registered using rigid and deformable algorithms. A similarity index was calculated to compare rigid and deformable registration algorithms. 3D absorbed dose calculation was carried out with the Raydose Monte Carlo code. The similarity analysis demonstrated the superiority of the deformable registrations (p < .001). Average absorbed dose to the kidneys calculated using rigid image registration was consistently lower than the average absorbed dose calculated using the deformable algorithm (90% of cases), with percentage differences in the range [-19; +4]%. Absorbed dose to lesions were also consistently lower (90% of cases) when calculated with rigid image registration with absorbed dose differences in the range [-67.2; 100.7]%. Deformable image registration had a significant role in calculating 3D absorbed dose to organs or lesions with volumes smaller than 100 mL. Image based 3D dosimetry for 177Lu-DOTATOC PRRT is significantly affected by the type of algorithm used to register sequential SPECT/CT scans.
On‐line in situ monitoring of radiation emitted by radiotracers during intravenous injection is of crucial importance for the safety of patients and personnel involved in nuclear medicine treatments and analysis. The aim of this work is to assess wearable perovskite ionizing radiation detectors for such application. With this purpose pixelated direct detector based on thin films of 2D layered perovskite PEA 2 PbBr 4 are tested for the monitoring of gamma‐rays emitted by 18 F radiopharmaceutical under different experimental conditions. The wearable detector is here demonstrated being able to detect in real‐time the gamma‐rays emitted by annihilation of 18 F radiotracer. Its reliability is assessed by 18 F half‐life measurement with a maximum accuracy deviation within 8%. The detector also successes in its validation for the foreseen application, demonstrating able to monitor in real‐time the whole injection process and extravasation event.