Karol Dąbrowski

Dr. Karol Dąbrowski

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2024 in Optics & Laser Technology
Verified
Journal Article
Closed access
KDKarol Dąbrowski
Karol Dąbrowski
WGWaldemar Gawron
Waldemar Gawron
ŁKŁukasz Kubiszyn
Łukasz Kubiszyn
BSBartłomiej Seredyński
Bartłomiej Seredyński
KMKrystian Michalczewski
Krystian Michalczewski
PMPiotr Martyniuk
Piotr Martyniuk

26 January 2024 in Infrared Physics & Technology
Verified
Journal Article
Closed access
KDKarol Dąbrowski
Karol Dąbrowski
ŁKŁukasz Kubiszyn
Łukasz Kubiszyn
BSBartłomiej Seredyński
Bartłomiej Seredyński
KMKrystian Michalczewski
Krystian Michalczewski
WGWaldemar Gawron
Waldemar Gawron
PMPiotr Martyniuk
Piotr Martyniuk

29 February 2024 in Photonics
Verified
Journal Article
Open access
PDF file
KDKarol Dąbrowski
Karol Dąbrowski
WGWaldemar Gawron
Waldemar Gawron
PMPiotr Martyniuk
Piotr Martyniuk
This paper presents a response time/time constant of III-V material-based interband long wavelength multistage infrared detector optimized for a wavelength of 10.6 µm at 200 K. The device is based on the InAs/InAsSb type-II superlattice with highly doped p+/n+ tunneling junctions among the stages. The detector exhibits a response time of 9.87 ns under zero voltage condition, while for 0.15 V reverse bias, that time decreases to approximately 350 ps. The presented device shows a significant increase in response time, especially for low bias, and for a voltage of −0.2 V, the decrease in the detector’s response time by an order of magnitude was estimated. Higher voltage slightly affects the time constant, and between −0.3 V and −1 V, it varies between 300 and 400 ps. The significant change in the detector’s response time between −0.1 V and −0.2 V probably results from electric field drop over entire absorber region. The optimal operating condition can be reached for −0.15 V, where the time constant reaches approximately 350 ns with peak detectivity at a level of ~3 × 109 Jones.

26 August 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Krzysztof MurawskiKrzysztof Murawski
Krzysztof Murawski
KMKinga Majkowycz
Kinga Majkowycz
MKMałgorzata Kopytko
Małgorzata Kopytko
TMTetiana Manyk
Tetiana Manyk
KDKarol Dąbrowski
Karol Dąbrowski
PMPiotr Martyniuk
Piotr Martyniuk
The long-wave infrared (LWIR) interband cascade detector with type-II superlattices (T2SLs) and a gallium-free (“Ga-free”) InAs/InAsSb (x = 0.39) absorber was characterized by photoluminescence (PL) and spectral response (SR) methods. Heterostructures were grown by molecular beam epitaxy (MBE) on a GaAs substrate (001) orientation. The crystallographic quality was confirmed by high-resolution X-Ray diffraction (HRXRD). Two independent methods, combined with theoretical calculations, were able to determine the transitions between the superlattice minibands. Moreover, transitions from the trap states were determined. Studies of the PL intensity as a function of the excitation laser power allowed the identification of optical transitions. The determined effective energy gap (Eg) of the tested absorber layer was 116 meV at 300 K. The transition from the first light hole miniband to the first electron miniband was red-shifted by 76 meV. The detected defects’ energy states were constant versus temperature. Their values were 85 meV and 112 meV, respectively. Moreover, two additional transitions from acceptor levels in cryogenic temperature were determined by being shifted from blue to Eg by 6 meV and 16 meV, respectively.

1 November 2024
Verified
Conference Paper
Closed access
PDF file
MKMalgorzata Kopytko
Malgorzata Kopytko
JSJan Sobieski
Jan Sobieski
KDKarol Dąbrowski
Karol Dąbrowski
WGWaldemar Gawron
Waldemar Gawron
JPJózef Piotrowski
Józef Piotrowski
The aim of the paper is to review the main achievements in the research of HgCdTe ternary alloy and InAs/InAsSb type-II superlattice material to indicate the Polish contribution to the development of medium and long wavelength infrared photodetectors. Research and development efforts in the WAT-VIGO joint laboratory have focused on the metal-organic chemical vapor deposition (from 2003) and molecular beam epitaxy (from 2015). At present stage of development, the photoconductive and photovoltaic HgCdTe detectors are gradually replaced with novel device designs based on III-V material system. T2SL devices complement the offer of MCT ones in applications where it is necessary to ensure, among others: higher resistance to difficult operating conditions and high uniformity of parameters of multi-element detectors.

28 October 2025 in Optics Letters
Verified
Journal Article
Closed access
KDKarol Dąbrowski
Karol Dąbrowski
WGWaldemar Gawron
Waldemar Gawron
ŁKŁukasz Kubiszyn
Łukasz Kubiszyn
BSBartłomiej Seredyński
Bartłomiej Seredyński
PMPiotr Martyniuk
Piotr Martyniuk
This paper presents the highest, to the best of our knowledge, performance reached for interband cascade detectors at VIGO Photonics, versus absorbers’ doping, thicknesses, and number of stages, for the 50% cut-off wavelength ( λ cut-off(50%) , the spectral response drops to 50% of its peak value), ranging from 6.1 to 13.9 µm and operating at room temperature (293 K). All analyzed devices were based on the InAs/InAsSb type-II superlattice (T2SL), where subsequent cells were connected by heavily doped p + /n + tunneling junctions. In the case of detectors optimized for the LWIR/VLWIR ranges, GaAs immersion lens technology was used to maximize performance. The peak detectivity ( D p e a k ∗ ) ranges from 7.46 × 10 7 Jones for the detector with λ cut-off(50%) ~13.9 µm, to 1.2 × 10 9 Jones for λ cut-off(50%) ~10.1 µm.