Miguel Antonio Cardoso Palomares

Mr. Miguel Antonio Cardoso Palomares


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Elliot Alonso Alcántara ArreolaElliot Alonso Alcántara Arreola
Elliot Alonso Alcántara Arreola
KSKarla Nayeli Silva-Garces
Karla Nayeli Silva-Garces
JMJocabed Mendoza-Martínez
Jocabed Mendoza-Martínez
MPMiguel Antonio Cardoso Palomares
Miguel Antonio Cardoso Palomares
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
Bone cortical tissues reorganize and remodel in response to tensile forces acting on them, while compressive forces cause atrophy. However, implants support most of the payload. Bones do not regenerate, and stress shielding occurs. The aim is to analyze the biomechanical behavior of a lumbar cage to study the implant’s stress shielding. The ASTM E-9 standard was used with the necessary adjustments to perform compression tests on lumbar and thoracic porcine spinal vertebrae. Twelve cases were analyzed: six with the metal prosthesis and six with the PEEK implant. A mathematical model based on the Hertz contact theory is proposed to assess the stress shielding for endoprosthesis used in spine pathologies. The lumbar spacer (screw) helps to reduce the stress shielding effect due to the ACME thread. The best interspinous spacer is the PEEK screw. It does not embed in bone. The deformation capability increases by 11.5% and supports 78.6 kg more than a system without any interspinous spacer.

13 July 2025 in Batteries
Verified
Journal Article
Open access
PDF file
MPMiguel Antonio Cardoso Palomares
Miguel Antonio Cardoso Palomares
Juan Carlos Paredes RojasJuan Carlos Paredes Rojas
Juan Carlos Paredes Rojas
JFJuan-Alejandro Flores-Campos
Juan-Alejandro Flores-Campos
AOARMANDO OROPEZA OSORNIO
ARMANDO OROPEZA OSORNIO
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
The increasing adoption of Light Electric Vehicles (LEVs) in urban areas, driven by the micromobility wave, raises significant safety concerns, particularly regarding battery fire incidents. This research investigates the electromechanical performance of aged 18650 lithium-ion batteries (LIBs) from LEVs under mechanical impact conditions. For this study, a battery module from a used e-scooter was disassembled, and its constituent cells were reconfigured into compact modules for testing. To characterize their initial condition, the cells underwent cycling tests to evaluate their state of health (SOH). Although a slight majority of the cells retained an SOH greater than 80%, a notable increase in their internal resistance (IR) was also observed, indicating degradation due to aging. The mechanical impact tests were conducted in adherence to the UL 2271:2018 standard, employing a semi-sinusoidal acceleration pulse. During these tests, linear kinematics were analyzed using videogrammetry, while key electrical and thermal parameters were monitored. Additionally, strain gauges were installed on the central cells to measure stress and deformation. The results from the mechanical shock tests revealed characteristic acceleration and velocity patterns. These findings clarify the electromechanical behavior of aged LIBs under impact, providing critical data to enhance the safety and reliability of these vehicles.

19 May 2023
Verified
Book Chapter
Closed access
PDF file
MPMiguel Antonio Cardoso Palomares
Miguel Antonio Cardoso Palomares
Juan Carlos Paredes RojasJuan Carlos Paredes Rojas
Juan Carlos Paredes Rojas
ADAdolfo Angel Casarez Duran
Adolfo Angel Casarez Duran
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel