Elliot Alonso Alcántara Arreola

Mr. Elliot Alonso Alcántara Arreola

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Elliot Alonso Alcántara ArreolaElliot Alonso Alcántara Arreola
Elliot Alonso Alcántara Arreola
KSKarla Nayeli Silva-Garces
Karla Nayeli Silva-Garces
JMJocabed Mendoza-Martínez
Jocabed Mendoza-Martínez
MPMiguel Antonio Cardoso Palomares
Miguel Antonio Cardoso Palomares
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
Bone cortical tissues reorganize and remodel in response to tensile forces acting on them, while compressive forces cause atrophy. However, implants support most of the payload. Bones do not regenerate, and stress shielding occurs. The aim is to analyze the biomechanical behavior of a lumbar cage to study the implant’s stress shielding. The ASTM E-9 standard was used with the necessary adjustments to perform compression tests on lumbar and thoracic porcine spinal vertebrae. Twelve cases were analyzed: six with the metal prosthesis and six with the PEEK implant. A mathematical model based on the Hertz contact theory is proposed to assess the stress shielding for endoprosthesis used in spine pathologies. The lumbar spacer (screw) helps to reduce the stress shielding effect due to the ACME thread. The best interspinous spacer is the PEEK screw. It does not embed in bone. The deformation capability increases by 11.5% and supports 78.6 kg more than a system without any interspinous spacer.

12 September 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
MHMarcial Francisco Hernández-Ortega
Marcial Francisco Hernández-Ortega
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
Elliot Alonso Alcántara ArreolaElliot Alonso Alcántara Arreola
Elliot Alonso Alcántara Arreola
Juan Carlos Paredes RojasJuan Carlos Paredes Rojas
Juan Carlos Paredes Rojas
OCOhtokani Cabrera-Rodríguez
Ohtokani Cabrera-Rodríguez
GUGuillermo Manuel Urriolagoitia-Calderón
Guillermo Manuel Urriolagoitia-Calderón
Interspinous spacers are a minimally invasive surgical device for treating degenerative lumbar diseases, limiting spinal extension, and decreasing pressures within the disc and facets, relieving symptoms caused by lumbar spinal stenosis. This work uses the finite element method to calculate the stresses and deformations of an interspinous spacer with steel wire clamping. The cables also provide an easier way to set up the device. The reconstruction of the model was undertaken by computerized tomography, considering a person with average Mexican height (1.64 m) and a mass index grade of 2 (108 kg). The maximum movements reported in the literature were used for the range of motion. The interspinous spacer increases in a ratio of 2.7 times the stresses. Still, these stresses are generated in the prosthesis, which causes the vertebrae to be relieved since the forces and pressures are reduced. Deformations decrease by 53% with the reduction of the range of motion. Therefore, the prosthesis provides excellent stability for the vertebrae.

18 June 2024 in Safety
Verified
Journal Article
Open access
ICIvan Lenin Cruz-Jaramillo
Ivan Lenin Cruz-Jaramillo
JTJose Luis Torres
Jose Luis Torres
Mario Grave-CapistránMario Grave-Capistrán
Mario Grave-Capistrán
Elliot Alonso Alcántara ArreolaElliot Alonso Alcántara Arreola
Elliot Alonso Alcántara Arreola
CGCarlos Alberto Espinoza Garcés
Carlos Alberto Espinoza Garcés
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
This study examined injuries sustained by a six-year-old child dummy in a numerical dolly rollover crash using a Toyota Yaris 2010. A harmonic dynamic system (HDS) composed of spring, dampers, and masses with a Low Back Booster (LBB) is denominated as HDS-LBB model. The HDS-LBB was designed to allow damping movements along three Cartesian axes (X, Y, Z) to reduce the energy transferred to the child by a motor vehicle accident and avoid a high injury risk. The HDS-LBB incorporates springs into the vertical axis to decrease the vertical movement during the rollover. The numerical analysis was conducted using LS-Dyna® R12.1 version during an interval of 1 s, and the boundary conditions were set by the Federal Motor Vehicle Safety Standard (FMVSS) 213 for child restraint recommendations and the FMVSS 208 for a dolly rollover procedure. Data on head and thorax decelerations, neck flexion-extension, and thoracic deflection were acquired at a rate of 1 ms. The injury values obtained by the HDS-LBB were compared with the injury values by another configuration denominated LBB-ISOFIX to assess the effectiveness of the model proposed. The results show a higher peak injury value in the neck and thorax because of seatbelt displacement across the child’s shoulder. Nevertheless, despite this seatbelt behavior, the injuries sustained remained below the Injury Assessment Reference Values (IARVS).

8 November 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FGFernando Guevara-Leon
Fernando Guevara-Leon
Mario Grave-CapistránMario Grave-Capistrán
Mario Grave-Capistrán
JFJuan-Alejandro Flores-Campos
Juan-Alejandro Flores-Campos
JTJose Luis Torres
Jose Luis Torres
Elliot Alonso Alcántara ArreolaElliot Alonso Alcántara Arreola
Elliot Alonso Alcántara Arreola
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
According to the World Health Organization (WHO), approximately 1.3 billion people experience visual impairments. Daily exposure to various levels of luminous beams directly impacts the front layer of the visible structure, leading to corneal injuries. To comprehensively understand this, we reconstructed a three-dimensional model utilizing the PENTACAM® system. This enabled us to accurately determine the 50th percentile dimensions of the fibrous layer of the eyeball. Using the Ogden mathematical model, we developed a 3D cornea model, treating it as a soft tissue with predictable behavior, considering mechanical properties such as viscoelasticity, anisotropy, and nonlinearity. Employing the Finite Element Method (FEM), we analyzed five distinct test scenarios to explore the structural response of the cornea. Luminous beam properties were instrumental in establishing varying mechanical loads, leading to structural deformations on the corneal surface. Our findings reveal that when a smartphone’s screen emits light at a frequency of 651.72 THz from 200 mm, displacements in the corneal layer can reach up to 9.07 µm. The total load, computed by the number of photons, amounts to 7172.637 Pa.

9 October 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
CGCarlos Alberto Espinoza Garcés
Carlos Alberto Espinoza Garcés
AMAxayácatl Morales-Guadarrama
Axayácatl Morales-Guadarrama
Elliot Alonso Alcántara ArreolaElliot Alonso Alcántara Arreola
Elliot Alonso Alcántara Arreola
JTJose Luis Torres
Jose Luis Torres
Mario Grave-CapistránMario Grave-Capistrán
Mario Grave-Capistrán
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
Some common conductive polymers are polyfuran, polyacetylene, polythiophene, and poly-pyrrole. Since their discovery, many researchers have been exploring and evaluating their conductive and electronic properties. Various applications have been developed for conductive materials. Their biocompatibility offers a new alternative for studying and solving complex problems, such as cellular activity, or, more recently, for use as neural implants and as an alternative to spinal cord regenerative tissue. This is particularly true for the use of poly pyrrole. The main obstacle lies in estimating some of the mechanical properties, such as Young’s or shear modulus values for poly pyrrole, since these vary depending on the type of synthesis used. This article outlines a composite methodology for characterizing the elastic modulus according to ASTM D882 and the shear modulus according to E143 standards. It is specifically designed and applied for 3D composite samples involving PLA and PPy, where the PPy was processed by plasma oxidation. As a result, an increase of 360.11 MPa in the modulus of elasticity is observed on samples coated with poly pyrrole. The results are evaluated through a numerical test using COMSOL Multiphysics software 6.2 version, finding a similar behavior in the elastic zone, as indicated by the stress–strain diagram. The statistical analysis yields consistent data for tensile and shear results, with low to moderate variability.

4 February 2025 in Materials
Verified
Journal Article
Open access
PDF file
Elliot Alonso Alcántara ArreolaElliot Alonso Alcántara Arreola
Elliot Alonso Alcántara Arreola
ARAIDA VERONICA RODRIGUEZ-TOVAR
AIDA VERONICA RODRIGUEZ-TOVAR
JHJosé Alejandro Hernández-Benítez
José Alejandro Hernández-Benítez
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
Spinal fusion is a surgical intervention used to join two or more vertebrae in the spine. An often-used method involves the placement of intervertebral spacers. They are commonly composed of biocompatible materials like polyetheretherketone. It has strength, longevity, and the capacity to interact harmoniously with the human body. Standardized mechanical tests were performed on two distinct implants to assess their biomechanical characteristics. The studies were conducted at a velocity of 2 mm/min. The stopping criteria were determined based on the loads sustained by the 50th percentile. Furthermore, the chemical composition of the implants was assessed using Raman spectroscopy. The implant created via subtractive manufacturing has a significant change in its elastic region at a force of 1300 N, and it begins subsidence when vertebrae are subjected to a load of 1500 N. The integration of microscopic characterization techniques with the mechanical analysis of prostheses in numerous case studies facilitates the biomechanical evaluation of implants.