Karla Nayeli Silva-Garces

Ms. Karla Nayeli Silva-Garces

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Elliot Alonso Alcántara ArreolaElliot Alonso Alcántara Arreola
Elliot Alonso Alcántara Arreola
KSKarla Nayeli Silva-Garces
Karla Nayeli Silva-Garces
JMJocabed Mendoza-Martínez
Jocabed Mendoza-Martínez
MPMiguel Antonio Cardoso Palomares
Miguel Antonio Cardoso Palomares
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
Bone cortical tissues reorganize and remodel in response to tensile forces acting on them, while compressive forces cause atrophy. However, implants support most of the payload. Bones do not regenerate, and stress shielding occurs. The aim is to analyze the biomechanical behavior of a lumbar cage to study the implant’s stress shielding. The ASTM E-9 standard was used with the necessary adjustments to perform compression tests on lumbar and thoracic porcine spinal vertebrae. Twelve cases were analyzed: six with the metal prosthesis and six with the PEEK implant. A mathematical model based on the Hertz contact theory is proposed to assess the stress shielding for endoprosthesis used in spine pathologies. The lumbar spacer (screw) helps to reduce the stress shielding effect due to the ACME thread. The best interspinous spacer is the PEEK screw. It does not embed in bone. The deformation capability increases by 11.5% and supports 78.6 kg more than a system without any interspinous spacer.

10 August 2024
Verified
Book Chapter
Closed access
PDF file
Luis Angel Guerrero HernándezLuis Angel Guerrero Hernández
Luis Angel Guerrero Hernández
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
JFJuan-Alejandro Flores-Campos
Juan-Alejandro Flores-Campos
KSKarla Nayeli Silva-Garces
Karla Nayeli Silva-Garces
Marco CeccarelliMarco Ceccarelli
Marco Ceccarelli

14 August 2024
Verified
Book Chapter
Closed access
PDF file
KSKarla Nayeli Silva-Garces
Karla Nayeli Silva-Garces
FJFiacro Jimenez-Ponce
Fiacro Jimenez-Ponce
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel

27 September 2024
Verified
Book Chapter
Closed access
PDF file
KSKarla Nayeli Silva-Garces
Karla Nayeli Silva-Garces
Matteo RussoMatteo Russo
Matteo Russo
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
Luis Angel Guerrero HernándezLuis Angel Guerrero Hernández
Luis Angel Guerrero Hernández
Marco CeccarelliMarco Ceccarelli
Marco Ceccarelli

23 May 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
KSKarla Nayeli Silva-Garces
Karla Nayeli Silva-Garces
Marco CeccarelliMarco Ceccarelli
Marco Ceccarelli
Matteo RussoMatteo Russo
Matteo Russo
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
This paper presents a new design solution for a neurosurgery-assisting device (NeurADe) based on a 3-RPS parallel kinematic mechanism. The NeurADe design employs compact linear actuators to accurately insert a cannula into specific areas of the brain. The CAD design and assembly of a prototype are discussed in this paper. The preliminary NeurADe prototype features 3D printed parts and incorporates mechanical and electrical components, which are designed for ease of use and lightweight functionality. For design validation and operational characterization, sensors measuring current, acceleration, and force data were utilized, and testing results are discussed to prove the feasibility of the proposed design.

5 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MMMiguel Ángel Martínez-Miranda
Miguel Ángel Martínez-Miranda
YYYosuke Yamamoto
Yosuke Yamamoto
SYShun Yasunaga
Shun Yasunaga
TKTetsuo Kan
Tetsuo Kan
CGCarlos Alberto Espinoza Garcés
Carlos Alberto Espinoza Garcés
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
This document provides a design description of a data acquisition device that allows an alert to be issued to suggest to the driver to take a break after having subjected his body to a certain amount of acceleration and pressure changes after driving on a road with too many curves. The tests were carried out using sensors based on microelectromechanical systems. The system was strategically installed at specific points on the body of the driver and car. Several electronic arrays were carried out, like the design of a printed circuit board. The establishment of an inter-integrated circuit communication and its multiplexing to work with several devices with the same address simultaneously. Finally, in this context, the document also presents the critical velocity for each curve in the Hakone roadway, which was obtained by using a mathematical model and contrasted with data acquisition values for acceleration. The risk of skidding on a curve increases when the driver does not reduce driving velocity; only a slight variance in acceleration or environmental conditions is enough. The value of acceleration was acquired for the analysis of each curve; there is a greater possibility of skidding in curves 2 and 4 because their radius is smaller and the critical speed is approximately 60 km/h, which is very close to the driving speed. On the other hand, the deceleration value of −0.65 G read on the head accelerometer can increase fatigue symptoms such as blurry vision or dizziness.