Lithium-ion batteries are widely used in power grids as a common form of energy storage in power stations. The state of charge (SOC) and state of health (SOH) reflect the capacity and lifetime variation in the Li-ion batteries, and they are important state parameters of Li-ion batteries. Therefore, the establishment of accurate SOC and SOH prediction models is an essential prerequisite for the correct assessment of the status of lithium batteries, the improvement of the operational accuracy of energy-storage stations, and the development of maintenance plans for energy-storage stations. This paper first analyzes the correlation between SOC and SOH, and then proposes a joint SOC and SOH prediction model using the particle swarm optimization (PSO) algorithm to optimize the extreme gradient boosting algorithm (XGBoost), which takes into account the dynamic correlation between SOC and SOH dynamics, thus enabling more accurate SOC and SOH prediction. Finally, the prediction model is validated using the Oxford battery aging dataset. The correlation between SOC and SOH is verified by comparing the joint prediction results with the SOC individual prediction results. Then, the prediction results of the PSO-XGBoost model, the traditional XGBoost model, and the long short-term memory neural network are compared to verify the effectiveness and accuracy of the PSO-XGBoost model.
For the optimal power distribution problem of battery energy storage power stations containing multiple energy storage units, a grouping control strategy considering the wind and solar power generation trend is proposed. Firstly, a state of charge (SOC) consistency algorithm based on multi-agent is proposed. The adaptive power distribution among the units started can be realized using this algorithm. Then, considering the trend of wind and solar power generation, a reasonable grouping control strategy is formulated. The grouping situation of the units is determined by using the probability distribution characteristics of energy storage charging and discharging, which reduces the number of charging and discharging conversions and extends the power station life. Finally, the actual data of a wind–solar energy storage microgrid is used to verify the method. The simulation results demonstrate that the proposed method has certain advantages in terms of control effect, SOC consistency, and extending the power station life.
1 March 2020 in IOP Conference Series: Materials Science and Engineering
In this paper, the impact of distributed photovoltaic (PV) access on the power quality and fault cur-rent of distribution network is studied. First of all, the constant power output of photovoltaic power model is adopted and the influence of the access of distributed photovoltaic on distribution net-work voltage deviation and voltage harmonic are analyzed; secondly, the change of fault current is analyzed considering fault at the upstream, downstream and adjacent feeder of the distributed PV access location respectively; finally, practical example is calculated based on above theoretical analysis, and the maximum penetration of PV is calculated in comprehensive consideration of power quality and existing protection setting value.