Acute hemodynamic decompensation (AHD) during ventricular tachycardia (VT) ablation occurs in about 11% of cases. Prophylactic use of temporary mechanical circulatory support (pro‐tMCS) has been applied to prevent AHD during VT ablation, but evidence supporting this practice is still lacking. This systematic review and meta‐analysis assessed the procedural characteristics and outcomes of pro‐tMCS for VT ablation. PubMed/Medline was screened until February 2020. Articles including adults receiving pro‐tMCS for VT ablation were included, and a meta‐analysis to compare proMCS and no‐tMCS was performed. Primary outcome was in‐hospital/30‐day mortality. Five observational studies presenting 400 procedures (pro‐tMCS: n = 187; no‐tMCS: n = 213) were included. Baseline characteristics were comparable between groups. Impella and TandemHeart were used in 86.6% and 13.4% of cases, respectively. In the pro‐tMCS group, more VTs were induced (mean difference: 0.52, confidence interval [CI]: 0.26‐0.77, P < .0001), and patients remained in VT on average for 24.04 minutes longer (CI: 18.28‐29.80, P < .00001). Procedural success was comparable between groups, as was VT recurrence. Pro‐tMCS patients had an odds ratio of 0.55 (CI: 0.28‐1.05, P = .07) for in‐hospital/30‐day mortality and 0.55 (CI: 0.32‐0.94, P = .03) for mortality at follow‐up. Sixty‐four percent of no‐tMCS patients received rescue tMCS. The most common tMCS‐related complications were bleeding events. Pro‐tMCS allowed for a prolonged time on VTs and the induction of more VTs. Although these advantages were not associated with differences in procedural success, VT recurrence, or in‐hospital/30‐day mortality in the overall population, pro‐tMCS might improve long‐term survival. Further prospective studies are urgently needed to confirm these results.
Background: Driveline (DL) damages are a common difficulty among ventricular assist devices (VAD). Repairing the electrical fibers inside the DL on a running pump is hazardous and requires technical expertise, which is not easily available on site. A new feature of the HeartMate3 (Abbott, U.S.A.) LVAD is a modular driveline that allows an easy exchange of the DL cord. In this report we analyze our experiences with this feature.Methods: We performed a retrospective analysis of 302 patients who underwent either HeartMate II or HeartMate 3 implantation between February 2004 and September 2021. Patients were screened for driveline faults and need for exchange or repair of driveline or VAD exchange. Documented were baseline characteristics, reasons for DL or VAD exchange, and complications. Follow‐up was three months after the procedure.Results: We present a cohort of 302 patients who underwent either HMII (n = 107;35.4%) or HM 3 (n = 195; 64.5%) implantation. Out of those, 40 patients (40/302; 13.2%) required driveline repair (DLRe) or exchange (DLEx). Out of 107 HMII patients, 9 showed severe DL damages (9/107; 8.4%). Six patients (6/9; 66.6%) underwent DLRe, two patients (2/6; 33.3%) required VAD exchange after DLRe, one patient (1/2;50%) experienced emergency VAD exchange after pump stop. The DLRe procedure in the other four patients (4/6; 66.6%) was successful. Due to damage to the internal driveline two patients (2/9; 22.2%) underwent emergency device exchange and one patient (1/9;11.1%) was listed for transplantation. 31 out 195 HM3 patients underwent exchange of the modular DL. In none of the cases, damages of the internal fibers were the reasons for the exchange. In 100% of the cases, damages of the external coating were the reason for DL exchange. In none of the cases, complications occurred after the exchange procedure.Conclusions: Driveline damages are a habitual, recurrent complication in VAD patients. The exchange of the modular driveline cable of the HM3 is feasible and safe compared to the conventional DL repair in HMII patients. Risky repair attempts and surgical LVAD exchange due to major damages of the electrical fibers can be avoided successfully by the new feature of HM3 driveline.
Background: Peripartum cardiomyopathy (PPCM) is a rare cause of heart failure (HF), presenting with left ventricular (LV) systolic dysfunction either at the end of pregnancy or in the months following delivery. In rare cases, PPCM leads to severe impairment of LV function, refractory cardiogenic shock or advanced HF. LV assist devices (LVAD) have been shown to be a feasible treatment option in advanced HF. However, little is known about long‐term outcomes and prognosis of PPCM patients undergoing LVAD implantation.Methods: A retrospective analysis of data from PPCM patients undergoing LVAD implantation in two tertiary centers with respect to long‐term outcomes was performed.Results: Twelve patients of median age 30 (18–39) years were included. Eight patients were experiencing cardiogenic shock (INTERMACS 1) at implantation. Seven patients were implanted within 1 month of their PPCM diagnosis. Median duration of LVAD support was 19 (2–92) months with median follow up of 67 (18–136) months (100% complete). In‐hospital and 1‐year mortality were 0% and 8.3%, respectively. Two patients died on LVAD support, four patients were successfully bridged to transplantation, two patients are still on LVAD, and four were successfully weaned due to sufficient LV recovery (one died after LV function deteriorated again).Conclusion: LVAD treatment of decompensated end‐stage PPCM is feasible. Early LVAD provision led to hemodynamic stabilization in our cohort and facilitated safe LV recovery in one third of these young female patients.
Literature on the air travel activities of patients supported by permanent mechanical assist devices is rare. To the best of our knowledge, no air travel guidelines or fitness prerequisites exist on whether and when ventricular assist device (VAD) patients are allowed to travel by plane after device implantation. In this study, we evaluated the topic of air travel after VAD implantation. This working group aimed to produce a report on air travel passengers supported by VADs, regarding their fitness to fly. Fifty left ventricular assist device (LVAD) patients were surveyed in a worldwide multicenter study. The single survey was performed with a multimethod design, including interviews conducted face‐to‐face, online, and on phone. Out of 50 patients, 97% described their traveling by aircraft as perfect and uneventful during the flight. Eighty‐five percent of the study participants consulted their medical practitioner before the flight. No patient reported the occurrence of a severe condition associated with flying. LVAD alarms, especially low flow alarms, did not occur in any of the devices. Thirty‐five percent of the surveyed patients, however, stated a major problem pertaining to the security check procedures at the airport. The results of this study suggest that commercial air travel is safe for stable patients on permanent VAD support and traveling can be resumed securely after VAD implantation. Conscientious preparation by packing necessary devices, fluids, medications, and careful preparation for the airport security check is recommended.
Background: Patients receiving left ventricle assist devices (LVADs) as bridge to recovery remain a minority with 1%–5% of LVADs explanted after improvement of myocardial function. Nevertheless, considering the growing population of patients supported with LVADs, an increasing demand of new explantation strategies is expected in the near future. A novel plug for LVAD explantation has been developed and its biocompatibility profile needs to be proved. This study tested the biocompatibility of this novel plug in an in vivo ovine model.Methods: Six adult Blackhead Persian female sheep received plug implantation on the cardiac apex via minimally invasive approach and were clinically observed up to 90 days. Echocardiography was performed to detect thrombus formation or further plug‐related complications. After the observation period, euthanasia was performed and samples including the plug and the surrounding tissues were obtained to be analyzed with correlative light and electron microscopy. Organ necrosis, ischemia and peripheral embolism were investigated.Results: Three animals survived surgery and completed the follow‐up time without experiencing clinical complications. Echocardiographic controls excluded the presence of an intracavitary thrombus in the left ventricle (LV). Autopsy confirmed no signs of local infection, LV thrombus or peripheral embolism. Light and electron microscopy revealed an intact epithelium covering a layer of connective tissue on the plug surface facing the heart lumen.Conclusions: This novel apical plug for LVAD explantation allows for endothelial and connective tissue growth on its ventricular side within 90 days from surgery. Further studies are required to fully demonstrate the biocompatibility of this apical plug and investigate the optimal anticoagulation regimen to be applied after implantation.
An intra‐cavitary left ventricular (LV) thrombus is a relative contraindication to LV assist device (LVAD) implantation based on increased thromboembolic risks. Herein, we present our experience with LVAD patients with or without preoperative diagnosis of LV‐thrombus. We retrospectively investigated 563 patients who received LVAD implantation between 2004 and 2018. Diagnosis of LV‐thrombus was verified with computed tomography scan, magnetic resonance imaging, echocardiography, or intraoperative LV inspection. The primary endpoint was 30‐day survival free of stroke and pump thrombosis. Overall, 72 patients (12.8%) had a diagnosis of LV‐thrombus. They were younger (51 years; IQR:41‐59), affected by severely reduced ejection fraction (15%; IQR:10‐20), more often presenting with dilated cardiomyopathy (61.8%) and INTERMACS profile 1 (33.3%). Preoperative atrial fibrillation was frequent in patients without LV‐thrombus (38.9%). Conventional sternotomy was the preferred approach in LV‐thrombus patients (77.8%), based on more HMII implantations in these patients (41.7%). Survival free of strokes and pump thrombosis at 30 days was comparable (P = .5751) between patients with (83.3%) or without LV‐thrombus (80.9%). LVAD implantation in patients with preoperative LV‐thrombus is safe and feasible. When managed through correct diagnostic and intraoperative strategies including accurate inspection of the LV cavity, these patients show similar 30‐day outcomes compared to patients without LV‐thrombus.