Tong Li

Dr. Tong Li

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2022 in Artificial Organs
Verified
Journal Article
Open access
SMSilvia Mariani
Silvia Mariani
MPMaria Elena De Piero
Maria Elena De Piero
JRJustine Mafalda Ravaux
Justine Mafalda Ravaux
ASAlexander Saelmans
Alexander Saelmans
MKMichal J. Kawczynski
Michal J. Kawczynski
RLRoberto Lorusso
Roberto Lorusso
Objective: Myocardial damage occurs in up to 25% of coronavirus disease 2019 (COVID‐19) cases. While veno‐venous extracorporeal life support (V‐V ECLS) is used as respiratory support, mechanical circulatory support (MCS) may be required for severe cardiac dysfunction. This systematic review summarizes the available literature regarding MCS use rates, disease drivers for MCS initiation, and MCS outcomes in COVID‐19 patients. Methods: PubMed/EMBASE were searched until October 14, 2021. Articles including adults receiving ECLS for COVID‐19 were included. The primary outcome was the rate of MCS use. Secondary outcomes included mortality at follow‐up, ECLS conversion rate, intubation‐to‐cannulation time, time on ECLS, cardiac diseases, use of inotropes, and vasopressors. Results: Twenty‐eight observational studies (comprising both ECLS‐only populations and ECLS patients as part of larger populations) included 4218 COVID‐19 patients (females: 28.8%; median age: 54.3 years, 95%CI: 50.7–57.8) of whom 2774 (65.8%) required ECLS with the majority (92.7%) on V‐V ECLS, 4.7% on veno‐arterial ECLS and/or Impella, and 2.6% on other ECLS. Acute heart failure, cardiogenic shock, and cardiac arrest were reported in 7.8%, 9.7%, and 6.6% of patients, respectively. Vasopressors were used in 37.2%. Overall, 3.1% of patients required an ECLS change from V‐V ECLS to MCS for heart failure, myocarditis, or myocardial infarction. The median ECLS duration was 15.9 days (95%CI: 13.9–16.3), with an overall survival of 54.6% and 28.1% in V‐V ECLS and MCS patients. One study reported 61.1% survival with oxy‐right ventricular assist device. Conclusion: MCS use for cardiocirculatory compromise has been reported in 7.3% of COVID‐19 patients requiring ECLS, which is a lower percentage compared to the incidence of any severe cardiocirculatory complication. Based on the poor survival rates, further investigations are warranted to establish the most appropriated indications and timing for MCS in COVID‐19.

18 January 2016 in Experimental and Therapeutic Medicine
Verified
Journal Article
Open access
PDF file
YXYizhi Xiao
Yizhi Xiao
XZXiaoxia Zuo
Xiaoxia Zuo
YYYunhui You
Yunhui You
HLHui Luo
Hui Luo
LDLiping Duan
Liping Duan
HZHongjun Zhao
Hongjun Zhao
Idiopathic inflammatory myopathy (IIM) is an autoimmune disease characterized by chronic muscle weakness and myositis with unknown etiology. IIM may affect the function of multiple organs and has a poor prognosis. In the present study, the causes of mortality in patients with IIM admitted to the Xiangya Hospital during the last 14 years were investigated. The investigation included an analysis of frequent causes of IIM, and of infections and associated complications. A cohort study was conducted on 676 patients with IIM that were admitted to Xiangya Hospital from January, 2001 to January, 2015. There were 49 patient mortalities (7.2% of the total cases), of which 34 mortalities were infection-associated and 15 were not infection-associated. The proportion of infection-associated IIM mortalities had increased since 2001. Of the 34 infection-associated mortalities, 31 cases (63.3%) were of fungal and bacterial infections, most frequently infecting the lungs and the blood. Klebsiella pneumoniae and Acinetobacter baumannii were the most commonly isolated pathogens, and co-infection with the two pathogens was observed in the majority of cases. In the IIM mortalities not associated with infection, there were 2 acute myocardial infarction cases, 2 acute interstitial lung disease cases, 4 malignancies and 1 case of each of the following: Arrhythmia, pneumothorax, ventilator weakness, pulmonary artery hypertension, gastrointestinal bleeding, liver failure and renal failure. Three mortalities were secondary to viral hepatitis in the present study. Pathogenic infection was the most frequent cause of mortality in patients with IIM. The remaining causes of mortality included secondary to heart failure, lung dysfunction and malignancy. Following the ubiquitous application of glucocorticoids and immunosuppressants, the proportion of infection-associated mortalities increased in patients with IIM. Thus, in addition to focusing on the primary disease, infection should receive increased attention during clinical practice.

29 April 2023 in The Journal of Heart and Lung Transplantation
Verified
Journal Article
Closed access
HTHongtao Tie
Hongtao Tie
TLTong Li
Tong Li
BHBi Huang
Bi Huang
SMSilvia Mariani
Silvia Mariani
TLTian Li
Tian Li
CDChen Dan
Chen Dan

8 October 2022 in Artificial Organs
Verified
Journal Article
Open access
AMAli Saad Merzah
Ali Saad Merzah
JHJasmin S. Hanke
Jasmin S. Hanke
TLTong Li
Tong Li
FMFadi A. Saad Merzah
Fadi A. Saad Merzah
MGMaria Gabriel
Maria Gabriel
GDGünes Dogan
Günes Dogan
Background: Driveline (DL) damages are a common difficulty among ventricular assist devices (VAD). Repairing the electrical fibers inside the DL on a running pump is hazardous and requires technical expertise, which is not easily available on site. A new feature of the HeartMate3 (Abbott, U.S.A.) LVAD is a modular driveline that allows an easy exchange of the DL cord. In this report we analyze our experiences with this feature.Methods: We performed a retrospective analysis of 302 patients who underwent either HeartMate II or HeartMate 3 implantation between February 2004 and September 2021. Patients were screened for driveline faults and need for exchange or repair of driveline or VAD exchange. Documented were baseline characteristics, reasons for DL or VAD exchange, and complications. Follow‐up was three months after the procedure.Results: We present a cohort of 302 patients who underwent either HMII (n = 107;35.4%) or HM 3 (n = 195; 64.5%) implantation. Out of those, 40 patients (40/302; 13.2%) required driveline repair (DLRe) or exchange (DLEx). Out of 107 HMII patients, 9 showed severe DL damages (9/107; 8.4%). Six patients (6/9; 66.6%) underwent DLRe, two patients (2/6; 33.3%) required VAD exchange after DLRe, one patient (1/2;50%) experienced emergency VAD exchange after pump stop. The DLRe procedure in the other four patients (4/6; 66.6%) was successful. Due to damage to the internal driveline two patients (2/9; 22.2%) underwent emergency device exchange and one patient (1/9;11.1%) was listed for transplantation. 31 out 195 HM3 patients underwent exchange of the modular DL. In none of the cases, damages of the internal fibers were the reasons for the exchange. In 100% of the cases, damages of the external coating were the reason for DL exchange. In none of the cases, complications occurred after the exchange procedure.Conclusions: Driveline damages are a habitual, recurrent complication in VAD patients. The exchange of the modular driveline cable of the HM3 is feasible and safe compared to the conventional DL repair in HMII patients. Risky repair attempts and surgical LVAD exchange due to major damages of the electrical fibers can be avoided successfully by the new feature of HM3 driveline.

27 September 2022 in Artificial Organs
Verified
Journal Article
Open access
DBDominik Berliner
Dominik Berliner
TLTong Li
Tong Li
SMSilvia Mariani
Silvia Mariani
RHRighab Hamdan
Righab Hamdan
JHJasmin S. Hanke
Jasmin S. Hanke
JSJan D. Schmitto
Jan D. Schmitto
Background: Peripartum cardiomyopathy (PPCM) is a rare cause of heart failure (HF), presenting with left ventricular (LV) systolic dysfunction either at the end of pregnancy or in the months following delivery. In rare cases, PPCM leads to severe impairment of LV function, refractory cardiogenic shock or advanced HF. LV assist devices (LVAD) have been shown to be a feasible treatment option in advanced HF. However, little is known about long‐term outcomes and prognosis of PPCM patients undergoing LVAD implantation.Methods: A retrospective analysis of data from PPCM patients undergoing LVAD implantation in two tertiary centers with respect to long‐term outcomes was performed.Results: Twelve patients of median age 30 (18–39) years were included. Eight patients were experiencing cardiogenic shock (INTERMACS 1) at implantation. Seven patients were implanted within 1 month of their PPCM diagnosis. Median duration of LVAD support was 19 (2–92) months with median follow up of 67 (18–136) months (100% complete). In‐hospital and 1‐year mortality were 0% and 8.3%, respectively. Two patients died on LVAD support, four patients were successfully bridged to transplantation, two patients are still on LVAD, and four were successfully weaned due to sufficient LV recovery (one died after LV function deteriorated again).Conclusion: LVAD treatment of decompensated end‐stage PPCM is feasible. Early LVAD provision led to hemodynamic stabilization in our cohort and facilitated safe LV recovery in one third of these young female patients.

17 January 2024 in Surgery
Verified
Journal Article
Closed access
PSPiotr Suwalski
Piotr Suwalski
EDEmil Julian Dąbrowski
Emil Julian Dąbrowski
Jakub BatkoJakub Batko
Jakub Batko
MPMichał Pasierski
Michał Pasierski
RLRadosław Litwinowicz
Radosław Litwinowicz
Mariusz KowalewskiMariusz Kowalewski
Mariusz Kowalewski