Shuo Zhang

Dr. Shuo Zhang

Shandong University, Jinan, Shandong, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
QHQiang Huang
Qiang Huang
Guibin ZouGuibin Zou
Guibin Zou
Shuo ZhangShuo Zhang
Shuo Zhang
HGHoulei Gao
Houlei Gao
Multi-terminal HVDC grid has extremely high demand for protection speed of DC lines, so the sampling time window of the main protection is very short, consequently, which affects its selectivity and reliability. To make up for the insufficiency of the non-unit main protection, this paper proposes a pilot protection scheme based on the voltage polarities of current-limiting reactors at the ends of DC lines. Analysis shows that the voltage polarities of terminal reactors at two ends of DC lines are both positive when internal fault occurs, while they are opposite for external faults. Based on the aforementioned characteristic difference, a pilot protection criterion is built to discriminate between internal and external faults. To avoid mal-operation of the protection on healthy pole generated by the coupling effect, the polarity mutation of reactor voltage on healthy pole due to coupling effect is analyzed when single-pole- to-ground fault occurs. Based on the analysis, the fault voltage of current-limiting reactor is integrated, and its polarity can be identified based on the integration value. At last, a four-terminal modular multilevel converter (MMC) based HVDC grid model is built in PSCAD/EMTDC, and the effectiveness of the protection scheme is verified by extensive simulations.

15 January 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Shuo ZhangShuo Zhang
Shuo Zhang
Guibin ZouGuibin Zou
Guibin Zou
Xiuyan WeiXiuyan Wei
Xiuyan Wei
CSChenjun Sun
Chenjun Sun
Hybrid DC circuit breaker (HCB) is currently the most promising DC circuit breaker (DCCB). However, since it requires hundreds of semiconductor switches to withstand high transient interruption voltage (TIV), the implementation cost is high. Besides, in the multi-terminal DC (MTDC) grid, three or more HCBs may be required at a DC bus, which worsens the disadvantages of HCBs in economy and volume. In order to solve this problem, this paper designs a diode-bridge multi-port HCB (DB-MPB) with its control procedures. By integrating the n HCBs at the DC bus to a single n-port HCB, the number of semiconductor switches and the footprint can be reduced, while the good current interruption performance can be still maintained. Besides, for the possibility of ultra-fast disconnector (UFD) failure, the proposed DB-MPB has the function of UFD failure protection. The effectiveness of the designed DB-MPB under different scenarios is verified by simulations and experimental tests. In addition, the performance comparisons in economy and functionality of the proposed DB-MPB with existed solutions are presented to highlight the advantages of the proposed solution.

1 September 2019 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
Shuo ZhangShuo Zhang
Shuo Zhang
GZGuibin Zou
Guibin Zou
BLBowei Li
Bowei Li
BXBin Xu
Bin Xu
JLJun Li
Jun Li

13 April 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Shuo ZhangShuo Zhang
Shuo Zhang
Guibin ZouGuibin Zou
Guibin Zou
XWXiuyan Wei
Xiuyan Wei
CZChengquan Zhang
Chengquan Zhang
The hybrid dc circuit breaker is one of the most promising dc circuit breakers (DCCBs). However, its cost is relatively high, and the completion of its fault isolation is significantly delayed because of the large current limiting inductors configured in the multiterminal dc grid. Besides, due to the utilization of overhead lines, the probability of temporary faults is much increased, which means there is a great possibility that the power supply can be rapidly restored by reclosing DCCBs. However, the temporary faults must be distinguished from the permanent faults before the reclosing operation to avoid damaging the fragile power electronic equipment. Therefore, considering the above issues, a novel multiport hybrid dc circuit breaker (MHCB) is proposed in this article. The MHCB mainly has three advantages: the reduced implementation cost by sharing the expensive main breaker among multiple lines, the reduced fault isolation time by bypassing the current limiting inductor during energy dissipation, and the ability to reclose softly. Extensive simulations and experiments verify the effectiveness of the device. In addition, the comparison of the new device and existed solutions is presented.

5 April 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Shuo ZhangShuo Zhang
Shuo Zhang
Guibin ZouGuibin Zou
Guibin Zou
FGFeng Gao
Feng Gao
Xiuyan WeiXiuyan Wei
Xiuyan Wei
CZChenghan Zhou
Chenghan Zhou
Voltage source converter–based multiterminal dc (MTdc) grids, including high- and medium-voltage levels, have attracted attention in recent years and developed fast. To protect the MTdc grids selectively, the dc circuit breaker (DCCB) is identified as the best choice. However, due to the high unit price and the required large number of DCCBs in the future large-scale MTdc grids, the total investment cost is unacceptable. Besides, the large volume and weight also limit their applications. To solve these problems, a variety of multiport dc circuit breakers (MPCBs) are proposed, which achieve significantly reduced costs and footprints by component sharing and device integration. This article first introduces the classifications and the basic principles of the existing MPCBs, and furthermore summarizes their technical requirements. Then, the economic and functional analysis of each MPCB is presented, and the performance comparisons among different topologies are elaborated. Finally, the challenges and future trends of the MPCBs are discussed and the findings are concluded.

9 September 2019 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
Shuo ZhangShuo Zhang
Shuo Zhang
Guibin ZouGuibin Zou
Guibin Zou
QHQiang Huang
Qiang Huang
BXBin Xu
Bin Xu
JLJun Li
Jun Li
This study proposes a novel non‐unit line protection for modular multilevel converter‐based (MMC) multi‐terminal high‐voltage direct current (MTDC) grids. On the basis of the symmetrical component analysis, the initial values of positive‐sequence voltage travelling waves (PSVTWs) generated by the fault are first investigated. Then, according to the TW theory and the inherent composition of the primary equipment of MMC‐MTDC grids, the initial values of PSVTWs on both sides of the series inductor are obtained in Laplace domain. Moreover, a fast fault line protection based on the positive‐sequence voltage on the series inductor at the line terminal is proposed. Besides, the method of the protection threshold determination is elaborated and is independent of simulation. Finally, extensive simulation studies are carried out in a four‐terminal MMC‐MTDC grid. Simulation results show the effectiveness of the proposed line protection method.