Multi-terminal HVDC grid has extremely high demand for protection speed of DC lines, so the sampling time window of the main protection is very short, consequently, which affects its selectivity and reliability. To make up for the insufficiency of the non-unit main protection, this paper proposes a pilot protection scheme based on the voltage polarities of current-limiting reactors at the ends of DC lines. Analysis shows that the voltage polarities of terminal reactors at two ends of DC lines are both positive when internal fault occurs, while they are opposite for external faults. Based on the aforementioned characteristic difference, a pilot protection criterion is built to discriminate between internal and external faults. To avoid mal-operation of the protection on healthy pole generated by the coupling effect, the polarity mutation of reactor voltage on healthy pole due to coupling effect is analyzed when single-pole- to-ground fault occurs. Based on the analysis, the fault voltage of current-limiting reactor is integrated, and its polarity can be identified based on the integration value. At last, a four-terminal modular multilevel converter (MMC) based HVDC grid model is built in PSCAD/EMTDC, and the effectiveness of the protection scheme is verified by extensive simulations.
30 September 2021 in IEEE Transactions on Smart Grid
The uncertainty in the direction and magnitude of fault current is a thorny issue for active distribution network (ADN) protection. Current differential protection (CDP) is suitable for ADN with complex operating modes and multiple types of DGs. However, the data synchronization conditions in transmission lines are usually not available in distribution systems with relatively low investment levels. Fault data self-synchronization (FDSS) algorithm is a low-cost data synchronization method specially used for the protection of distribution networks, but there will be large time synchronization errors under some extreme fault conditions. In this paper, the inherent defect of the conventional FDSS algorithm is first analyzed. Then an improved FDSS algorithm is proposed, which uses the current zero-crossing time and current slope polarity to estimate the starting delay difference at both terminals. On this basis, a corresponding CDP scheme is proposed. Compared with traditional CDP, the proposed scheme does not require additional synchronization equipment and high communication bandwidth. Finally, an ADN simulation model was built using PSCAD, and the improved FDSS algorithm program was implemented in MATLAB. Test results prove that the improved FDSS algorithm can effectively reduce the time synchronization error, and the corresponding CDP scheme is effective under various fault conditions.
15 January 2020 in IEEE Transactions on Industrial Electronics
Hybrid DC circuit breaker (HCB) is currently the most promising DC circuit breaker (DCCB). However, since it requires hundreds of semiconductor switches to withstand high transient interruption voltage (TIV), the implementation cost is high. Besides, in the multi-terminal DC (MTDC) grid, three or more HCBs may be required at a DC bus, which worsens the disadvantages of HCBs in economy and volume. In order to solve this problem, this paper designs a diode-bridge multi-port HCB (DB-MPB) with its control procedures. By integrating the n HCBs at the DC bus to a single n-port HCB, the number of semiconductor switches and the footprint can be reduced, while the good current interruption performance can be still maintained. Besides, for the possibility of ultra-fast disconnector (UFD) failure, the proposed DB-MPB has the function of UFD failure protection. The effectiveness of the designed DB-MPB under different scenarios is verified by simulations and experimental tests. In addition, the performance comparisons in economy and functionality of the proposed DB-MPB with existed solutions are presented to highlight the advantages of the proposed solution.
13 June 2022 in Protection and Control of Modern Power Systems
The emergence of distributed generators has changed the operational mode and fault characteristics of the distribution network, in a way which can severely influence protection. This paper proposes a d-axis-based current differential protection scheme. The d-axis current characteristics of inverter-interfaced distributed generators and synchronous generators are analyzed. The differential protection criterion using sampling values of the d-axis current component is then constructed. Compared to conventional phase-based current differential protection, the proposed protection reduces the number of required communication channels, and is suitable for distribution networks with inverter-interfaced distributed generators with complex fault characteristics. Finally, a 10 kV active distribution network model is built in the PSCAD platform and protection prototypes are developed in RTDS. Superior sensitivity and fast speed are verified by simulation and RTDS-based tests.
13 April 2021 in IEEE Transactions on Industrial Electronics
The hybrid dc circuit breaker is one of the most promising dc circuit breakers (DCCBs). However, its cost is relatively high, and the completion of its fault isolation is significantly delayed because of the large current limiting inductors configured in the multiterminal dc grid. Besides, due to the utilization of overhead lines, the probability of temporary faults is much increased, which means there is a great possibility that the power supply can be rapidly restored by reclosing DCCBs. However, the temporary faults must be distinguished from the permanent faults before the reclosing operation to avoid damaging the fragile power electronic equipment. Therefore, considering the above issues, a novel multiport hybrid dc circuit breaker (MHCB) is proposed in this article. The MHCB mainly has three advantages: the reduced implementation cost by sharing the expensive main breaker among multiple lines, the reduced fault isolation time by bypassing the current limiting inductor during energy dissipation, and the ability to reclose softly. Extensive simulations and experiments verify the effectiveness of the device. In addition, the comparison of the new device and existed solutions is presented.
5 April 2023 in IEEE Transactions on Power Electronics
Voltage source converter–based multiterminal dc (MTdc) grids, including high- and medium-voltage levels, have attracted attention in recent years and developed fast. To protect the MTdc grids selectively, the dc circuit breaker (DCCB) is identified as the best choice. However, due to the high unit price and the required large number of DCCBs in the future large-scale MTdc grids, the total investment cost is unacceptable. Besides, the large volume and weight also limit their applications. To solve these problems, a variety of multiport dc circuit breakers (MPCBs) are proposed, which achieve significantly reduced costs and footprints by component sharing and device integration. This article first introduces the classifications and the basic principles of the existing MPCBs, and furthermore summarizes their technical requirements. Then, the economic and functional analysis of each MPCB is presented, and the performance comparisons among different topologies are elaborated. Finally, the challenges and future trends of the MPCBs are discussed and the findings are concluded.