Hybrid DC circuit breaker (HCB) is currently the most promising DC circuit breaker (DCCB). However, since it requires hundreds of semiconductor switches to withstand high transient interruption voltage (TIV), the implementation cost is high. Besides, in the multi-terminal DC (MTDC) grid, three or more HCBs may be required at a DC bus, which worsens the disadvantages of HCBs in economy and volume. In order to solve this problem, this paper designs a diode-bridge multi-port HCB (DB-MPB) with its control procedures. By integrating the n HCBs at the DC bus to a single n-port HCB, the number of semiconductor switches and the footprint can be reduced, while the good current interruption performance can be still maintained. Besides, for the possibility of ultra-fast disconnector (UFD) failure, the proposed DB-MPB has the function of UFD failure protection. The effectiveness of the designed DB-MPB under different scenarios is verified by simulations and experimental tests. In addition, the performance comparisons in economy and functionality of the proposed DB-MPB with existed solutions are presented to highlight the advantages of the proposed solution.

5 April 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Shuo ZhangShuo Zhang
Shuo Zhang
Guibin ZouGuibin Zou
Guibin Zou
FGFeng Gao
Feng Gao
Xiuyan WeiXiuyan Wei
Xiuyan Wei
CZChenghan Zhou
Chenghan Zhou
Voltage source converter–based multiterminal dc (MTdc) grids, including high- and medium-voltage levels, have attracted attention in recent years and developed fast. To protect the MTdc grids selectively, the dc circuit breaker (DCCB) is identified as the best choice. However, due to the high unit price and the required large number of DCCBs in the future large-scale MTdc grids, the total investment cost is unacceptable. Besides, the large volume and weight also limit their applications. To solve these problems, a variety of multiport dc circuit breakers (MPCBs) are proposed, which achieve significantly reduced costs and footprints by component sharing and device integration. This article first introduces the classifications and the basic principles of the existing MPCBs, and furthermore summarizes their technical requirements. Then, the economic and functional analysis of each MPCB is presented, and the performance comparisons among different topologies are elaborated. Finally, the challenges and future trends of the MPCBs are discussed and the findings are concluded.

4 November 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Shuo ZhangShuo Zhang
Shuo Zhang
Guibin ZouGuibin Zou
Guibin Zou
Xiuyan WeiXiuyan Wei
Xiuyan Wei
CZChengquan Zhang
Chengquan Zhang
Two key challenges in meshed multi-terminal DC (MTDC) grids are line power flow management and fault current interruption, which can be solved by current flow controllers (CFCs) and hybrid DC circuit breakers (HCBs), respectively. However, the power losses and the implementation costs of CFCs and HCBs are relatively high. In order to overcome these drawbacks, a combined HCB (CHCB) is proposed in this paper by fully utilizing the core ideas of the interline dual H-bridge CFC and the HCB. The proposed device can substitute multiple HCBs at a DC bus with greatly reduced cost. In addition to the fault current interruption capability, the current flows in the adjacent lines can be controlled by the embedded multi-line CFC in the CHCB expanded from the existing interline dual H-bridge CFC. The system-level behavior of the proposed CHCB is similar to the separate solution of the typical HCB and the multi-line CFC. Extensive simulations and experiments verify the effectiveness of the proposed device. Besides, a comparison of the proposed CHCB and the separate solution is presented.

13 July 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Shuo ZhangShuo Zhang
Shuo Zhang
Guibin ZouGuibin Zou
Guibin Zou
Xiuyan WeiXiuyan Wei
Xiuyan Wei
CZChenghan Zhou
Chenghan Zhou
CZChengquan Zhang
Chengquan Zhang
The coordination configuration of current-limiting inductors (CLIs) and hybrid dc circuit breakers (HCBs) is currently the most commonly used fault handling method to ensure fault ride-through of multi-terminal dc (MTdc) grids after the dc-side fault occurs. However, the high cost of HCB limits its large-scale application. In addition, the installation of the large CLIs will adversely affect the HCB performance, such as extending the fault current interruption time and increasing the energy dissipation pressure of the arrester. To solve these problems, a multiport current-limiting hybrid dc circuit breaker (MCL-HCB) is proposed in this paper. Compared with the typical HCBs, the MCL-HCB can achieve full selective protection of all connected dc lines with significantly reduced investment costs. Besides, it can suppress the rising speed of the fault current by embedded CLIs, while eliminating their negative impacts on the fault current interruption. The feasibility and superiority of the proposed MCL-HCB are verified by simulations in the PSCAD/EMTDC software and experiments in the scaled-down experimental setup. Besides, the performance comparison between the MCL-HCB and existing solutions is elaborated.

9 August 2018 in Energies
Verified
Journal Article
Open access
PDF file
YZYu Zeng
Yu Zeng
Guibin ZouGuibin Zou
Guibin Zou
Xiuyan WeiXiuyan Wei
Xiuyan Wei
CSChenjun Sun
Chenjun Sun
LJLingtong Jiang
Lingtong Jiang
Nowadays, the efficient and reliable protection and location schemes for MMC-MVDC (Modular Multilevel Converter-Medium Voltage Direct Current) grid are few. This paper is the first to propose a scheme to not only protect the feeders and the busbar, but locate the segments in MMC-MVDC grid. To improve the reliability, this paper analyzes the transient characteristics of the pole-to-pole fault and then obtains the characteristic frequency band. Based on S-transform, STCFB (S-transform characteristic frequency band) Phase of fault component is utilized to construct the identification criterion for faulty feeder and faulty segment. The whole scheme can be divided into three steps, namely, protection starting criterion, faulty feeder and busbar protection criterion, and faulty segment location criterion. Firstly, the current gradient method is utilized to quickly detect the fault and start the protection device. Secondly, the non-unit protection criterion on busbar and feeders is proposed according to STCFB Phase of the voltage and current fault component. Thirdly, according to the STCFB Phase on both sides of the feeder segment, the faulty segment can be located. A radial MMC-MVDC distribution network model was built in PSCAD/EMTDC software to evaluate the performance of the protection and location method. Simulation results for different cases demonstrate that the proposed scheme has high accuracy, good adaptability and reliability.

26 October 2022 in IEEE Access
Verified
Journal Article
Open access
Xiuyan WeiXiuyan Wei
Xiuyan Wei
Guibin ZouGuibin Zou
Guibin Zou
Shuo ZhangShuo Zhang
Shuo Zhang
CXChunhua Xu
Chunhua Xu
The flexible DC distribution grid is suitable for distributed energy resource integration and DC load power supply. However, the fast-increasing fault current has a great impact on the system when a short circuit fault occurs. Besides, the existing main protections are easily affected by high resistance faults and converters. To solve the aforementioned problems, a pilot protection method using frequency domain (FD) impedance was proposed. Firstly, a direction criterion based on the polarity of FD reactance is constructed to identify the reverse fault. Furthermore, the values of FD reactance and resistance are used to distinguish the forward internal and external faults. The method uses only local information to identify the close-up fault, and the pilot protection criterion to identify the remote-end or high resistance faults. This combination of single-end and pilot protection criteria makes the method have high reliability and fast speed. Moreover, no data synchronization is needed. Finally, extensive simulations were utilized to verify the effectiveness of the proposed method.