In Kuwait, where the government subsidizes approximately 95% of residential electricity bills, most of the country’s energy consumption is for residential use. In particular, air-conditioning (AC) systems for cooling, which are used throughout the year, are responsible for residential electric energy consumption. This study aimed to reduce the amount of energy consumed for cooling purposes by developing a thermal comfort-based controller. Our study commenced by using a simulation model to investigate the possibility of energy reduction when using the predicted mean vote (PMV) for optimal control. The result showed that control optimization would enable the cooling energy consumption to be reduced by 33.5%. The influence of six variables on cooling energy consumption was then analyzed to develop a thermal comfort-based controller. The analysis results showed that the indoor air temperature was the most influential factor, followed by the mean radiant temperature, the metabolic rate, and indoor air velocity. The thermal comfort-based controller-version 1 (TCC-V1) was developed based on the analysis results and experimentally evaluated to determine the extent to which the use of the controller would affect the energy consumed for cooling. The experiments showed that the implementation of TCC-V1 control made it possible to reduce the electric energy consumption by 39.5% on a summer representative day. The results of this study indicate that it is possible to improve indoor thermal comfort while saving energy by using the thermal comfort-based controller in residential buildings in Kuwait.
The integration of photovoltaic (PV) into electric power systems has been widely explored and adopted to address the problems associated with the depletion of fossil fuels and the release of greenhouse gases. PV panels convert sunlight into electricity, minimizing the reliance on fossil fuels and mitigating environmental pollution. It is crucial to optimally utilize the PV power in the system; hence maximum power point tracking (MPPT) algorithms have been developed to ensure optimal performance of grid-connected PV systems at the maximum power point (MPP) despite changes in weather conditions. Moreover, deep reinforcement learning (DRL) developments provide a promising approach for optimizing grid-connected PV systems, replacing the conventional proportional-integral-derivative (PID) controllers. However, there is limited research evaluating the efficiency of these systems using DRL techniques. This paper proposes a new dandelion optimizer (DO)-based DRL for MPPT of grid-connected photovoltaic systems and evaluates the proposed method for a 100-MW PV plant connected to a 33-kV distribution system. The proposed DRL technique uses proximal policy optimization (PPO) and deep deterministic policy gradient (DDPG) algorithms for continuous states and discrete or continuous action spaces to adjust the PV-measured voltage based on a reference one produced via DO-PPO and DO-DDPG methods. To test the effectiveness and practicality of the introduced methods, simulations were conducted using actual input data of a 100 MW PV plant connected to a 33-kV distribution system for typical days in summer and winter seasons using MATLAB/Simulink software. The proposed implemented methods were evaluated by comparing their simulation results with other techniques: DO-PID, particle swarm optimization (PSO), and incremental conductance (InC-PI). The findings revealed that the efficiencies of the DC-DC boost and the voltage source converters using the introduced methods were 84.25%-85.90%, and 78.33%-81.10% on a summer day while they were 92.77%-95% and 86.70%-89.50% on a winter day, respectively, which proves that these methods were efficient and effective, indicating their promising potential for future applications.
Globally, energy standards for new buildings are being reinforced to improve energy efficiency, and remodeling policies are being promoted for old buildings. The South Korean Government is promoting green remodeling projects, and focusing on research and product development to improve the performance of old windows and curtain walls. In line with this, the present study proposes two remodeling methods using polymer dispersed liquid crystal (PDLC) films, which can adjust solar radiation for old office buildings. In addition, energy efficiency improvement and daylight performance according to remodeling were analyzed. Attaching PDLC films to the glass of old curtain walls was analyzed; this can reduce heating and cooling energy, reduce the annual discomfort glare occurrence rate, and increase the annual indoor appropriate illuminance ratio. Furthermore, producing a window by laminating a PDLC film between two sheets of glass and putting it over the existing curtain wall was also analyzed; this can reduce annual building energy consumption and the annual discomfort glare occurrence rate, and improve the annual indoor appropriate illuminance ratio. Therefore, PDLC film is expected to be applicable as a next-generation green remodeling material because using it in remodeling can improve energy efficiency of old office buildings and indoor daylight performance.
Electrochromic glass is anticipated as the next generation of solar control glass for construction because it can control the transmittance of the glass itself. This study analyzed building energy and light environment performance by applying electrochromic glass in triple glazing in order to verify both the solar control characteristics of electrochromic glass and its high insulation performance. This paper evaluates the performance of the electrochromic glass developed by our research team in Korea in five control conditions of varying temperatures and solar radiation levels. By analyzing the cooling and heating load, lighting energy, Daylight Glare Index (DGI), and interior illuminance when applying the selected conditions to office buildings, this paper discerns the optimal control conditions for electrochromic glass. To do so, the optical characteristic data of the electrochromic glass was analyzed via an experiment, and the creation of triple glazing for construction was conducted. The performance of electrochromic glass was evaluated by analyzing hourly and yearly data for cooling, heating load, and lighting energy during a typical day in summer and winter. From this analysis, the control condition with an outstanding performance from an energy perspective was identified. The performance of the light environment was assessed, and the EDPI overall evaluation index was used to find the electrochromic glass’ optimum control conditions for integrating energy and light environment.
Windows are essential in buildings; however, they have poor thermal performance, so extensive research has been conducted on improving their performance. In this study, we developed vacuum-glazed windows with excellent insulation via the in-vacuum method, which shortens the manufacturing time and vacuuming degree considerably. In addition, the configuration of the pillars, low-emissivity (low-e) coating, and frame from a thermal performance perspective was experimentally optimized. The results revealed that the optimal pillar placement spacing is 40 mm and that the low-e coating surface must be located inside the vacuum layer to maximize insulation performance. The vacuum-glazed window produced by the in-vacuum method was applied to an actual residential building to investigate its thermal performance, which was compared with that of a triple-glazed window. The results showed that the center-of-glazing heat flow of the vacuum-glazed window was approximately 0.8 W/m2K lower than that of the triple-glazed window. The difference between the average indoor and outdoor surface temperatures during the nighttime was found to be up to 35.1 °C for the vacuum-glazed window and 23.1 °C for the triple-glazed window. Therefore, the energy efficiency of the building can be greatly improved by applying vacuum windows manufactured via the in-vacuum method and optimized for the best thermal performance.