Objective: The high transparency of dental enamel in the near‐IR (NIR) light at 1,310‐nm can be exploited for imaging dental caries without the use of ionizing radiation (X‐rays). We present the results of the first in vivo imaging study in which NIR images were acquired of approximal contact surfaces.Methods: NIR imaging hand‐pieces were developed and attached to a compact InGaAs focal plane array and subsequently used to acquire in vivo NIR images of 33 caries lesions on 18 test subjects. The carious lesions were discernible on bitewing radiographs, but were not visible upon clinical examination.Results: NIR images were acquired in vivo from three directions and the majority of lesions examined were too small to require restoration, based on accepted bitewing radiograph criteria. All but one of the 33 lesions examined were successfully imaged from at least one direction.Conclusion: This first in vivo study of imaging at the 1,310‐nm wavelength region shows that NIR imaging has great potential as a screening tool for the detection of approximal lesions without the use of ionizing radiation. Lasers Surg. Med. 42:292–298, 2010.
In Kuwait, where the government subsidizes approximately 95% of residential electricity bills, most of the country’s energy consumption is for residential use. In particular, air-conditioning (AC) systems for cooling, which are used throughout the year, are responsible for residential electric energy consumption. This study aimed to reduce the amount of energy consumed for cooling purposes by developing a thermal comfort-based controller. Our study commenced by using a simulation model to investigate the possibility of energy reduction when using the predicted mean vote (PMV) for optimal control. The result showed that control optimization would enable the cooling energy consumption to be reduced by 33.5%. The influence of six variables on cooling energy consumption was then analyzed to develop a thermal comfort-based controller. The analysis results showed that the indoor air temperature was the most influential factor, followed by the mean radiant temperature, the metabolic rate, and indoor air velocity. The thermal comfort-based controller-version 1 (TCC-V1) was developed based on the analysis results and experimentally evaluated to determine the extent to which the use of the controller would affect the energy consumed for cooling. The experiments showed that the implementation of TCC-V1 control made it possible to reduce the electric energy consumption by 39.5% on a summer representative day. The results of this study indicate that it is possible to improve indoor thermal comfort while saving energy by using the thermal comfort-based controller in residential buildings in Kuwait.
Globally, energy standards for new buildings are being reinforced to improve energy efficiency, and remodeling policies are being promoted for old buildings. The South Korean Government is promoting green remodeling projects, and focusing on research and product development to improve the performance of old windows and curtain walls. In line with this, the present study proposes two remodeling methods using polymer dispersed liquid crystal (PDLC) films, which can adjust solar radiation for old office buildings. In addition, energy efficiency improvement and daylight performance according to remodeling were analyzed. Attaching PDLC films to the glass of old curtain walls was analyzed; this can reduce heating and cooling energy, reduce the annual discomfort glare occurrence rate, and increase the annual indoor appropriate illuminance ratio. Furthermore, producing a window by laminating a PDLC film between two sheets of glass and putting it over the existing curtain wall was also analyzed; this can reduce annual building energy consumption and the annual discomfort glare occurrence rate, and improve the annual indoor appropriate illuminance ratio. Therefore, PDLC film is expected to be applicable as a next-generation green remodeling material because using it in remodeling can improve energy efficiency of old office buildings and indoor daylight performance.
Windows are essential in buildings; however, they have poor thermal performance, so extensive research has been conducted on improving their performance. In this study, we developed vacuum-glazed windows with excellent insulation via the in-vacuum method, which shortens the manufacturing time and vacuuming degree considerably. In addition, the configuration of the pillars, low-emissivity (low-e) coating, and frame from a thermal performance perspective was experimentally optimized. The results revealed that the optimal pillar placement spacing is 40 mm and that the low-e coating surface must be located inside the vacuum layer to maximize insulation performance. The vacuum-glazed window produced by the in-vacuum method was applied to an actual residential building to investigate its thermal performance, which was compared with that of a triple-glazed window. The results showed that the center-of-glazing heat flow of the vacuum-glazed window was approximately 0.8 W/m2K lower than that of the triple-glazed window. The difference between the average indoor and outdoor surface temperatures during the nighttime was found to be up to 35.1 °C for the vacuum-glazed window and 23.1 °C for the triple-glazed window. Therefore, the energy efficiency of the building can be greatly improved by applying vacuum windows manufactured via the in-vacuum method and optimized for the best thermal performance.
The performance of the Operable Building Integrated Photovoltaic (OBIPV) system applied to the building envelope to reduce the building energy consumption varies significantly depending on the operation method and influence of the surrounding environment. Therefore, optimization through performance monitoring is necessary to maximize power generation of the system. This study used temperature-corrected normalized efficiency (NE*) to evaluate the power generation performance of the operation methods and predict that of the OBIPV system based upon the measured data. It was confirmed that power generation performance decreased when the photovoltaic (PV) operation angle changed, the system remaining the same. A decrease in power generation performance due to partial shading from an overhang was also observed. As a result of the power generation prediction for two months using NE*, the error of the measured values was found to be less than 3%. In addition, with or without any partial shading of the OBIPV system, its performance degradation was predicted with an annual electricity generation decrease by 36 kWh/yr (6.5%). Therefore, NE* can be used as an indicator for evaluating the power generation performance of PV systems, and to predict generation performance considering partial shading.