Nanna Sutter Rolighed

Dr. Nanna Sutter Rolighed

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2020 in Neurogastroenterology & Motility
Verified
Journal Article
Closed access
PDF file
MKMette Winther Klinge
Mette Winther Klinge
AHAnne‐Mette Haase
Anne‐Mette Haase
EMEsben Bolvig Mark
Esben Bolvig Mark
NRNanna Sutter Rolighed
Nanna Sutter Rolighed
LFLotte Vinskov Fynne
Lotte Vinskov Fynne
KKKlaus Krogh
Klaus Krogh

10 March 2020 in Neurogastroenterology & Motility
Verified
Journal Article
Open access
PDF file
NRNanna Sutter Rolighed
Nanna Sutter Rolighed
MKMette Winther Klinge
Mette Winther Klinge
EMEsben Bolvig Mark
Esben Bolvig Mark
GNGursharan Kaur Nandhra
Gursharan Kaur Nandhra
AHAnne‐Mette Haase
Anne‐Mette Haase
KKKlaus Krogh
Klaus Krogh
Background: The Motilis 3D‐Transit system allows ambulatory description of transit patterns throughout the gastrointestinal tract and offers an alternative method for studying gastric motility. We aimed to establish normative values for gastric motility assessed with the method.Method: A total of 132 healthy volunteers ingested the 3D‐Transit capsule for assessment of gastrointestinal transit times. Recordings from 125 subjects were used for definition of normative values. Forty‐six subjects were studied on two consecutive days. Recordings were reanalyzed using newly developed software providing information on gastric emptying (GE) as well as contraction frequency and movement during gastric contractions.Results: The median GE time was 2.7 hours (range 0.1‐21.2). In 89% of subjects, the capsule passed the pylorus within a postingestion period of 6 hours. The median frequency of gastric contractions was 3.1 per minute (range 2.6‐3.8). The frequency was higher in women (3.2, range 2.7‐3.8) than in men (3.0, range 2.6‐3.5) and increased with age (0.004 per year) (P < .05). The median amplitudes were 35° (range 4‐85) when based on rotation of the capsule and 11 mm (range 6‐31) when based on capsule change in position. The rotation amplitude was higher in women and decreased with increasing BMI (P < .05). The position amplitude was also higher in women and increased with the amount of calories in the test meal, but decreased with increasing BMI and age (P < .05). Day‐to‐day variation (P > .05) was considerable while inter‐rater variability was small.Conclusion and Inferences: We have established normative values for gastric motility assessed with the 3D‐Transit system.

1 December 2020 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
CBChristian Emil Brinck
Christian Emil Brinck
EMEsben Bolvig Mark
Esben Bolvig Mark
MKMette Winther Klinge
Mette Winther Klinge
CECecilie Ejerskov
Cecilie Ejerskov
NRNanna Sutter Rolighed
Nanna Sutter Rolighed
KKKlaus Krogh
Klaus Krogh
Capsule-based methods for assessment of gastrointestinal (GI) motility have seen great improvements in recent decades. The most recent development is the electromagnetic Motilis 3D-Transit system (3D-Transit). The aim of this paper is to review and discuss the development and technical properties of magnetic tracking of GI motility. We performed a comprehensive literature review on magnetic tracking in GI research. The motility tracking system was the first capsule-based magnetic system to be used in GI motility research. However, the potential of the system was hampered by its stationary and hospitalizing nature. This led to the development of the electromagnetic Motilis 3D-Transit system. The 3D-Transit system is a portable system that allows for assessment of both whole gut and regional transit times and contraction patterns in a fully ambulatory setting in the patients’ home environment with only minor restrictions on movements. The spatiotemporal resolution of 3D-Transit allows assessment of segmental colonic transit times and permits an analysis of gastric and colonic movements with a degree of detail unrivalled by other ambulatory methods, such as the wireless motility capsule. Recently, robust normative data on 3D-Transit have been published. This review provides a current perspective on the use of capsule-based magnetic tracking systems in GI research and how they represent a potentially valuable clinical resource for GI physicians and in GI research.

25 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MKMette W. Klinge
Mette W. Klinge
AHAnnemette Haase
Annemette Haase
NRNanna Sutter Rolighed
Nanna Sutter Rolighed
KKKlaus Krogh
Klaus Krogh
MSMark Scott
Mark Scott
ALAnders Bergh Lødrup
Anders Bergh Lødrup
Background/Objectives: Chronic nausea and vomiting (N/V) disorders are common in clinical practice. Our primary aim was to compare total and segmental gastrointestinal transit times as well as gastric contraction patterns in patients with chronic N/V syndrome to those of healthy volunteers (HVs). In the patient group, our secondary aim was to explore how symptoms and motility patterns were affected by a serotonin HT4 receptor agonist (Prucalopride). Methods: Patients with chronic N/V syndrome and HVs underwent baseline assessment of regional gastrointestinal (GI) motility/transit using the Motilis 3D-Transit system. Patients were then treated with Prucalopride 2 mg daily for 28 days, with the 3D-transit examination repeated within 10–20 days after treatment onset. Two self-administered questionnaires (the Gastrointestinal Symptom Rating Scale [GSRS] and Gastroparesis Cardinal Symptom Index [GCSI]) were used to assess patients’ symptoms. Results: A total of 19 patients (13 F; median age 25 years (IQR 22–39) and 55 HVs (25 F; median age 28 (24–35) were included. At baseline, no differences in regional GI transit times were found between groups. However, patients had a significantly lower gastric contraction amplitude than HVs (9 mmHg (IQR 8–11) vs. 12 (10–15: p < 0.001). In response to Prucalopride treatment, gastric emptying time was reduced from a median of 3.1 h to 1.6 h (p < 0.005). Further, the GCSI was significantly reduced from GCSI 3.0 (IQR 2.3–3.7) at baseline to GCSI 1.9 (IQR 1.3–3.2) with Prucalopride. Conclusions: Patients with chronic N/V syndrome have significantly lower gastric contraction amplitude than HVs and may symptomatically benefit from prokinetics. They do not, however, have evidence of panenteric dysmotility.