Ji Sang Yoon

Dr. Ji Sang Yoon

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
JYJi Sang Yoon
Ji Sang Yoon
HKHyunhye Kang
Hyunhye Kang
DJDong Wook Jekarl
Dong Wook Jekarl
SLSung-Eun Lee
Sung-Eun Lee
Eun-Jee OhEun-Jee Oh
Eun-Jee Oh
Serum erythropoietin (sEPO) is an initial screening tool for distinguishing polycythemia vera (PV) from secondary erythrocytosis (SE), but defining ‘subnormal’ sEPO levels for PV diagnosis remains contentious, complicating its clinical utility. This study compares the diagnostic performance of sEPO across established subnormal limits, including reference interval (RI), clinical decision limit (CDL), and functional reference limit. sEPO levels were analyzed in 393 healthy donors (HDs) and 90 patients (41 PV and 49 SE), who underwent bone marrow biopsy and genetic tests due to erythrocytosis. The RI (2.5–97.5 percentile from HDs) of sEPO was 5.3–26.3 IU/L. A CDL of 3.1 IU/L, determined by ROC analysis in erythrocytosis patients, had a sensitivity of 80.5% and specificity of 87.8% for diagnosing PV. A functional reference limit of 7.0 IU/L, estimated based on the relationship between sEPO and hemoglobin, hematocrit, and WBC, increased sensitivity to 97.6% but decreased specificity to 46.7%. Using 5.3 IU/L as a ‘subnormal’ limit identified all three JAK2-negative PV cases, increasing the sensitivity and negative predictive value to 97.6% and 97.0%, respectively. Combining the RI, CDL, and functional reference limit may improve PV diagnostic accuracy.

13 October 2025 in Annals of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
JYJi Sang Yoon
Ji Sang Yoon
JKJoo An Kwon
Joo An Kwon
JSJeong Seob Shin
Jeong Seob Shin
HSHyun Soo Seok
Hyun Soo Seok
IYIn Young Yoo
In Young Yoo
YPYeon-Joon Park
Yeon-Joon Park
Ji Sang Yoon, M.D., Joo An Kwon, M.T., Jeong Seob Shin, M.T., Hyun Soo Seok, M.T., In Young Yoo, M.D., Ph.D., and Yeon-Joon Park, M.D., Ph.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2025.0246

21 July 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
HLHyeyoung Lee
Hyeyoung Lee
ACAe-Ran Choi
Ae-Ran Choi
HPHye-Sun Park
Hye-Sun Park
JKJoungOk Kim
JoungOk Kim
SPSeo-A Park
Seo-A Park
Eun-Jee OhEun-Jee Oh
Eun-Jee Oh
Background/Objectives: Since the World Health Organization (WHO) recommended HIV self-testing as an alternative to traditional facility-based testing in 2016, it has been increasingly adopted worldwide. This study aimed to evaluate the performance of the ConfiSign HIV Self-Test (GenBody Inc., Republic of Korea), a newly developed blood-based immunochromatographic assay for the qualitative detection of total antibodies (IgG and IgM) against HIV-1/HIV-2. Methods: The evaluation included four components: (1) retrospective analysis of 1400 archived serum samples (400 HIV-positive and 1000 HIV-negative samples), (2) prospective self-testing by 335 participants (112 HIV-positive participants and 223 individuals with an unknown HIV status, including healthy volunteers), (3) assessment using seroconversion panels and diverse HIV subtypes, and (4) analytical specificity testing for cross-reactivity and interference. The Elecsys HIV combi PT and Alinity I HIV Ag/Ab Combo assays were used as reference assays. Results: In retrospective testing, the ConfiSign HIV Self-Test achieved a positive percent agreement (PPA) of 100%, a negative percent agreement (NPA) of 99.2%, and a Cohen’s kappa value of 0.986, showing excellent agreement with the reference assays. In the prospective study, the test showed 100% sensitivity and specificity, with a low invalid result rate of 1.8%. All HIV-positive samples, including those with low signal-to-cutoff (S/Co) values in the Alinity I assay, were correctly identified. The test also reliably detected early seroconversion samples and accurately identified a broad range of HIV-1 subtypes (A, B, C, D, F, G, CRF01_AE, CRF02_AG, and group O) as well as HIV-2. No cross-reactivity or interference was observed with samples that were positive for hepatitis viruses, cytomegalovirus, Epstein–Barr virus, varicella zoster virus, influenza, HTLV-1, HTLV-2, or malaria. Conclusions: The ConfiSign HIV Self-Test demonstrated excellent sensitivity, specificity, and robustness across diverse clinical samples, supporting its reliability and practicality as a self-testing option for HIV-1/2 antibody detection.