RUBEN PASCUAL JIMENEZ

Mr. RUBEN PASCUAL JIMENEZ

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2023 in IEEE Access
Verified
Journal Article
Open access
RJRUBEN PASCUAL JIMENEZ
RUBEN PASCUAL JIMENEZ
Carlos A. PlateroCarlos A. Platero
Carlos A. Platero
MSMarcos Esteban Sánchez
Marcos Esteban Sánchez
EBEduardo Rivero Barneto
Eduardo Rivero Barneto
The massive integration of renewable energies into the grid towards the de-carbonisation of the power system has a major impact on the stability of the grid. This has led the European Union to establish guidelines on how renewable plants should be connected to the grid, in order to continue to guarantee their operation and stability. These requirements are contained in the European Grid Code. In this code, there are requirements concerning voltage control, reactive power capacity, fault-ride-through and short-circuit current contribution capabilities of renewable power plants. These plants, in particular those powered by photovoltaic inverters, have issues of reactive power capacity, so in order to be able to connect to the grid, they usually require an oversized of the inverters or the installation of reactive power compensation elements, such as capacitor banks, static VAR compensator or synchronous condensers. Moreover, the fault-ride-through and short-circuit current contribution are difficult to fulfil as they are inverter-based generators have a low capacity to supply short-circuit current and, in some cases, they disconnect from the grid. These facts have produced large power losses and protection malfunctions in power system with high photovoltaic power penetration. This paper studies the compliance of the European Grid Code of a 500 MW photovoltaic power plant with and without a synchronous condenser. The results show that not only the use of the synchronous condenser helps for reactive power regulation but also for fault-ride-through and short-circuit current contribution.

1 December 2023 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
RJRUBEN PASCUAL JIMENEZ
RUBEN PASCUAL JIMENEZ
KMKumar Mahtani
Kumar Mahtani
EREduardo Rivero
Eduardo Rivero
Carlos A. PlateroCarlos A. Platero
Carlos A. Platero
Interturn faults (ITF) at the main machine field winding in brushless synchronous machines (BSM) are not easy to detect as the scarcity of measurements in the rotor. This paper presents a new field winding ITF severity estimation technique based on deep learning algorithms. The theoretical exciter field current is calculated through an artificial neural network, from the machine output values, and then compared to the measured exciter field current. The estimation and the comparison are carried out without need of other than the machine electrical outputs and the exciter field current measurements. To verify the proposed technique, numerous healthy and faulty condition tests were performed on a special laboratory testbench, with more than 7 million measurements in healthy and more than 1 million in different faulty conditions. So as firstly to train the neural network with healthy operation datasets, and secondly to test its capability to estimate the fault severity level. The use of deep neural networks has proven to enhance the accuracy of the exciter field current estimation with respect to previous theoretical model-based methods, enabling to increase the sensitivity and the reliability of the fault detection and fault severity calculation.

6 May 2025 in Machines
Verified
Journal Article
Open access
PDF file
RJRUBEN PASCUAL JIMENEZ
RUBEN PASCUAL JIMENEZ
MSMarcos Esteban Sánchez
Marcos Esteban Sánchez
JGJose Manuel Guerrero
Jose Manuel Guerrero
Carlos A. PlateroCarlos A. Platero
Carlos A. Platero
This work presents the development of an adaptive thermal protection system for synchronous machines (SMs), taking into consideration the final cooling temperature and the operation point of the machine. This system aims to improve current thermal protections, which consist of a fixed alarm and trip thresholds regardless of the generator’s operating point or ambient temperature. A recurrent neural network (RNN)-based approach has been employed to predict SM temperatures during operation. Multiple tests have been conducted on a specially designed test bench. Inside the windings and iron core of the 5.5 kVA generator, multiple Pt100 sensors have been installed to train the neural network with real temperature values, enabling accurate predictions. The selected RNN model is Long Short-Term Memory (LSTM). Its inputs include electrical variables and the inlet and outlet air temperatures of the SM’s cooling system. The results show that the model accurately defines warning and trip thresholds, significantly improving thermal protection, as these thresholds are no longer fixed values. Additionally, the study suggests validating the model under cooling system failures and exploring its application in water-cooled systems. This research is supported by a patent on real-time thermal diagnostics for synchronous machines, highlighting its potential contribution to predictive maintenance and the monitoring of power generation systems.

26 November 2024 in Electronics
Verified
Journal Article
Open access
PDF file
KMKumar Mahtani
Kumar Mahtani
JDJulien Decroix
Julien Decroix
RJRUBEN PASCUAL JIMENEZ
RUBEN PASCUAL JIMENEZ
JGJose Manuel Guerrero
Jose Manuel Guerrero
Carlos A. PlateroCarlos A. Platero
Carlos A. Platero
This paper presents an advanced automatic fault classification method for detecting rotating rectifier faults in brushless synchronous machines (BSMs). The proposed approach employs a multilayer perceptron (MLP) neural network to classify the operational states of the rotating rectifier, including healthy conditions and common fault types: open-diode (OD), shorted-diode (SD), and open-phase (OP). Key machine measurements, available on an ordinary basis in the industry, such as active power (P), reactive power (Q), stator voltage (U), and excitation current (Ie), are used as inputs for this model, allowing for non-invasive, real-time fault detection. This model achieved an overall classification accuracy of 93.4%, with a precision of 94.9% for fault detection and strong recall performance across multiple fault types. The neural network’s robustness is enhanced by advanced data processing techniques, including Gaussian filtering and class balancing through the synthetic minority over-sampling technique (SMOTE). Experimental testing on a modified 5-kVA BSM setup, where rectifier faults were systematically induced, was used to train the network and validate the model’s performance. This method provides a promising tool for real-time condition monitoring of BSMs, improving machine reliability and minimizing downtime in industrial applications.

9 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RJRUBEN PASCUAL JIMENEZ
RUBEN PASCUAL JIMENEZ
EREduardo Rivero
Eduardo Rivero
JGJose Manuel Guerrero
Jose Manuel Guerrero
KMKumar Mahtani
Kumar Mahtani
Carlos A. PlateroCarlos A. Platero
Carlos A. Platero
There are numerous methods for detecting interturn faults (ITFs) in the field winding of synchronous machines (SMs). One effective approach is based on comparing theoretical and measured excitation currents. This method is unaffected by rotor temperature in static excitation SMs. However, this paper investigates the influence of rotor temperature in brushless synchronous machines (BSMs), where rotor temperature significantly impacts the exciter excitation current. Extensive experimental tests were conducted on a special BSM with measurable rotor temperature. Given the challenges of measuring rotor temperature in industrial machines, this paper explores the feasibility of using stator temperature in the exciter field current estimation model. The theoretical exciter field current is calculated using a deep neural network (DNN), which incorporates electrical brushless synchronous generator output values and stator temperature, and it is subsequently compared with the measured exciter field current. This method achieves an error rate below 0.5% under healthy conditions, demonstrating its potential for simple implementation in industrial BSMs for ITF detection.

1 September 2026 in IEEE Industry Applications Magazine
Verified
Journal Article
Closed access
MMMiguel Martinez-Lozano
Miguel Martinez-Lozano
JGJose Manuel Guerrero
Jose Manuel Guerrero
RJRUBEN PASCUAL JIMENEZ
RUBEN PASCUAL JIMENEZ
DTDavid Talavera
David Talavera
KMKumar Mahtani
Kumar Mahtani
Carlos A. PlateroCarlos A. Platero
Carlos A. Platero