YingLiang Ma

Dr. YingLiang Ma

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2024 in IEEE Access
Verified
Journal Article
Open access
NBNadia Bibi
Nadia Bibi
FWFazli Wahid
Fazli Wahid
YMYingLiang Ma
YingLiang Ma
SASikandar Ali
Sikandar Ali
Irshad Ahmed AbbasiIrshad Ahmed Abbasi
Irshad Ahmed Abbasi
KHKhyber
Khyber
In order to improve patient outcomes, brain tumors—which are notorious for their catastrophic effects and short life expectancy, particularly in higher grades—need to be diagnosed accurately and treated with care. Patient survival chances may be hampered by incorrect medical procedures brought on by a brain tumor misdiagnosis. CNNs and computer-aided tumor detection systems have demonstrated promise in revolutionizing brain tumor diagnostics through the application of ML techniques. One issue in the field of brain tumor detection and classification is the dearth of non-invasive indication support systems, which is compounded by data scarcity. Conventional neural networks may cause problems such as overfitting and gradient vanishing when they use uniform filters in different visual settings. Moreover, these methods incur time and computational complexity as they train the model from scratch and extract the pertinent characteristics. This paper presents an InceptionV4 neural network architecture-based Transfer Learning-based methodology to address the shortcomings in brain tumor classification methods. The goal is to deliver precise diagnostic assistance while minimizing calculation time and improving accuracy. The model makes use of a dataset that contains 7022 MRI images that were obtained from figshare, the SARTAJ dataset, and Br35H, among other sites. The suggested InceptionV4 architecture improves its ability to categorize brain tumors into three groups and normal brain images by utilizing transfer learning approaches. The suggested InceptionV4 model achieves an accuracy rate of 98.7% in brain tumor classification, indicating the model’s remarkable performance. This suggests a noteworthy progression in the precision of diagnosis and computational effectiveness to support practitioners making decisions.

30 September 2014 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
XWXianliang Wu
Xianliang Wu
James HousdenJames Housden
James Housden
YMYingLiang Ma
YingLiang Ma
BRBenjamin Razavi
Benjamin Razavi
Kawal RhodeKawal Rhode
Kawal Rhode
DRDaniel Rueckert
Daniel Rueckert
Echocardiography is a potential alternative to X-ray fluoroscopy in cardiac catheterization given its richness in soft tissue information and its lack of ionizing radiation. However, its small field of view and acoustic artifacts make direct automatic segmentation of the catheters very challenging. In this study, a fast catheter segmentation framework for echocardiographic imaging guided by the segmentation of corresponding X-ray fluoroscopic imaging is proposed. The complete framework consists of: 1) catheter initialization in the first X-ray frame; 2) catheter tracking in the rest of the X-ray sequence; 3) fast registration of corresponding X-ray and ultrasound frames; and 4) catheter segmentation in ultrasound images guided by the results of both X-ray tracking and fast registration. The main contributions include: 1) a Kalman filter-based growing strategy with more clinical data evaluation; 2) a SURF detector applied in a constrained search space for catheter segmentation in ultrasound images; 3) a two layer hierarchical graph model to integrate and smooth catheter fragments into a complete catheter; and 4) the integration of these components into a system for clinical applications. This framework is evaluated on five sequences of porcine data and four sequences of patient data comprising more than 3000 X-ray frames and more than 1000 ultrasound frames. The results show that our algorithm is able to track the catheter in ultrasound images at 1.3 s per frame, with an error of less than 2 mm. However, although this may satisfy the accuracy for visualization purposes and is also fast, the algorithm still needs to be further accelerated for real-time clinical applications.

1 May 2020
Verified
Conference Paper
Closed access
ANAnh Nguyen
Anh Nguyen
DKDennis Kundrat
Dennis Kundrat
GDGiulio Dagnino
Giulio Dagnino
WCWenqiang Chi
Wenqiang Chi
MAMohamed E. M. K. Abdelaziz
Mohamed E. M. K. Abdelaziz
GYGuang-Zhong Yang
Guang-Zhong Yang
Accurate real-time catheter segmentation is an important pre-requisite for robot-assisted endovascular intervention. Most of the existing learning-based methods for catheter segmentation and tracking are only trained on smallscale datasets or synthetic data due to the difficulties of ground-truth annotation. Furthermore, the temporal continuity in intraoperative imaging sequences is not fully utilised. In this paper, we present FW-Net, an end-to-end and real-time deep learning framework for endovascular intervention. The proposed FW-Net has three modules: a segmentation network with encoder-decoder architecture, a flow network to extract optical flow information, and a novel flow-guided warping function to learn the frame-to-frame temporal continuity. We show that by effectively learning temporal continuity, the network can successfully segment and track the catheters in real-time sequences using only raw ground-truth for training. Detailed validation results confirm that our FW-Net outperforms stateof-the-art techniques while achieving real-time performance.

1 June 2014 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Open access
RKRashed Karim
Rashed Karim
YMYingLiang Ma
YingLiang Ma
MJMunjung Jang
Munjung Jang
James HousdenJames Housden
James Housden
SWSteven E. Williams
Steven E. Williams
Kawal RhodeKawal Rhode
Kawal Rhode
Surface flattening in medical imaging has seen widespread use in neurology and more recently in cardiology to describe the left ventricle using the bull's-eye plot. The method is particularly useful to standardize the display of functional information derived from medical imaging and catheter-based measurements. We hypothesized that a similar approach could be possible for the more complex shape of the left atrium (LA) and that the surface flattening could be useful for the management of patients with atrial fibrillation (AF). We implemented an existing surface mesh parameterization approach to flatten and unfold 3D LA models. Mapping errors going from 2D to 3D and the inverse were investigated both qualitatively and quantitatively using synthetic data of regular shapes and computer tomography scans of an anthropomorphic phantom. Testing of the approach was carried out using data from 14 patients undergoing ablation treatment for AF. 3D LA meshes were obtained from magnetic resonance imaging and electroanatomical mapping systems. These were unfolded using the developed approach and used to demonstrate proof-of-concept applications, such as the display of scar information, electrical information and catheter position. The work carried out shows that the unfolding of complex cardiac structures, such as the LA, is feasible and has several potential clinical uses for the management of patients with AF. (C) 2014 The Authors. Published by Elsevier Ltd. All rights reserved.

5 August 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
YMYingLiang Ma
YingLiang Ma
DZDiwei Zhou
Diwei Zhou
LYLei Ye
Lei Ye
RHR. James Housden
R. James Housden
AFAnsab Fazili
Ansab Fazili
KRKawal S. Rhode
Kawal S. Rhode
Objective: Catheters and wires are used extensively in cardiac catheterization procedures. Detecting their positions in fluoroscopic X-ray images is important for several clinical applications such as motion compensation and co-registration between 2D and 3D imaging modalities. Detecting the complete length of a catheter or wire object as well as electrode positions on the catheter or wire is a challenging task. Method: In this paper, an automatic detection framework for catheters and wires is developed. It is based on path reconstruction from image tensors, which are eigen direction vectors generated from a multiscale vessel enhancement filter. A catheter or a wire object is detected as the smooth path along those eigen direction vectors. Furthermore, a real-time tracking method based on a template generated from the detection method was developed. Results: The proposed framework was tested on a total of 7,754 X-ray images. Detection errors for catheters and guidewires are 0.56 ± 0.28 mm and 0.68 ± 0.33 mm, respectively. The proposed framework was also tested and validated in two clinical applications. For motion compensation using catheter tracking, the 2D target registration errors (TRE) of 1.8 mm ± 0.9 mm was achieved. For co-registration between 2D X-ray images and 3D models from MRI images, a TRE of 2.3 ± 0.9 mm was achieved. Conclusion: A novel and fully automatic detection framework and its clinical applications are developed. Significance: The proposed framework can be applied to improve the accuracy of image-guidance systems for cardiac catheterization procedures.

17 October 2018 in Medical Physics
Verified
Journal Article
Open access
PDF file
YMYingLiang Ma
YingLiang Ma
MAMazen Alhrishy
Mazen Alhrishy
SNSrinivas Ananth Narayan
Srinivas Ananth Narayan
PMPeter Mountney
Peter Mountney
Kawal RhodeKawal Rhode
Kawal Rhode
Purpose: Catheters and guidewires are used extensively in cardiac catheterization procedures such as heart arrhythmia treatment (ablation), angioplasty, and congenital heart disease treatment. Detecting their positions in fluoroscopic X‐ray images is important for several clinical applications, for example, motion compensation, coregistration between 2D and 3D imaging modalities, and 3D object reconstruction.Methods: For the generalized framework, a multiscale vessel enhancement filter is first used to enhance the visibility of wire‐like structures in the X‐ray images. After applying adaptive binarization method, the centerlines of wire‐like objects were extracted. Finally, the catheters and guidewires were detected as a smooth path which is reconstructed from centerlines of target wire‐like objects. In order to classify electrode catheters which are mainly used in electrophysiology procedures, additional steps were proposed. First, a blob detection method, which is embedded in vessel enhancement filter with no additional computational cost, localizes electrode positions on catheters. Then the type of electrode catheters can be recognized by detecting the number of electrodes and also the shape created by a series of electrodes. Furthermore, for detecting guiding catheters or guidewires, a localized machine learning algorithm is added into the framework to distinguish between target wire objects and other wire‐like artifacts. The proposed framework were tested on total 10,624 images which are from 102 image sequences acquired from 63 clinical cases.Results: Detection errors for the coronary sinus (CS) catheter, lasso catheter ring and lasso catheter body are 0.56 ± 0.28 mm, 0.64 ± 0.36 mm, and 0.66 ± 0.32 mm, respectively, as well as success rates of 91.4%, 86.3%, and 84.8% were achieved. Detection errors for guidewires and guiding catheters are 0.62 ± 0.48 mm and success rates are 83.5%.Conclusion: The proposed computational framework do not require any user interaction or prior models and it can detect multiple catheters or guidewires simultaneously and in real‐time. The accuracy of the proposed framework is sub‐mm and the methods are robust toward low‐dose X‐ray fluoroscopic images, which are mainly used during procedures to maintain low radiation dose.