Longlei Bai

Prof. Dr. Longlei Bai


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Bo LuoBo Luo
Bo Luo
HWHuan Wu
Huan Wu
MWMengyao Wang
Mengyao Wang
FWFangrui Wang
Fangrui Wang
LBLonglei Bai
Longlei Bai
JYJiang You
Jiang You
Monitoring coupler parameters in underwater wireless power transfer (UWPT) systems is crucial for improving the system transmission characteristics. Due to the eddy current effect, the equivalent circuits of the magnetic coupler are more complex and contain more parameters than those in air-based circuits. Traditional parameter identification methods, which rely on solving circuit matrix equations, often struggle with the complex UWPT systems or require significant computational resources to solve high-order multivariate equations. This article proposes a coupler parameter identification method based on the adaptive moment estimation with a weighted adjustment (Adam-W) optimization algorithm to address the multiparameter identification problems in the UWPT system. This method transforms the problem of solving high-order matrix equations into an optimization problem to address multiparameter identification problem caused by seawater eddy effect, which is challenging for traditional methods. In addition, it facilitates online monitoring of the characteristic parameters of the system's coupler by detecting the system's front-end input current and voltage without wireless communication and additional sensor modules, and exhibits better reliability in underwater environments. The experimental results show that the proposed Adam-W algorithm achieves a high parameter identification accuracy within 1 s and 94 iterations with an average error of 2.78%. Comparably, an average error of 56.74% is achieved by gradient descent and 41.49% by adaptive moment estimation, and 37.42% by particle swarm optimization in 150 iterations. The proposed Adam-W algorithm achieves higher accuracy in parameter identification of the UWPT system within a shorter time and demonstrates better applicability in seawater environments.

21 September 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LGLei Guo
Lei Guo
WCWeidong Cao
Weidong Cao
LBLonglei Bai
Longlei Bai
JZJingkang Zhang
Jingkang Zhang
LXLimeng Xing
Limeng Xing
LZLijun Zhou
Lijun Zhou
The problem to identify the type of source generating discharges detected during campaigns of partial discharge (PD) measurements in cable terminal is of utmost importance in the quality control and state detection of power supply system of high-speed railway train. The purpose of this paper is to provide a novel PD feature and a potential tool for cable terminal PD identification. The traditional PD type of high-speed train cable terminal is usually identified by PD test parameters, such as amplitude, PD times and discharge energy. These features contain limited information and are easily affected by external factors, resulting in large numerical fluctuations, making the reliability of the test results low, which makes the operation, maintenance and repair decision of high-speed train cables very difficult. Therefore, this paper proposes a method that can extract rich feature information from PD data, and can distinguish PD types accurately and reliably by combining with classification algorithm. Firstly, to make full use of the characteristics of PD data, the single-scale PRPD images are transformed into multi-scale PRPD images by using image pyramid theory. Then, the first-order texture statistics, the second-order texture statistics, and the higher-order texture statistics are extracted from the multi-scale PRPD space. Finally, the input features are optimized and classified by random forest, and compared with other feature extraction algorithms. The results show that this method can identify PD type accurately and reliably, and the recognition accuracy is better than that of single PD discharge feature.

7 September 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LZLijun Zhou
Lijun Zhou
LBLonglei Bai
Longlei Bai
JZJingkang Zhang
Jingkang Zhang
WCWeidong Cao
Weidong Cao
EXEnxin Xiang
Enxin Xiang
In the alpine region, there are many flashover failures of ethylene-propylene rubber (EPR) cable terminations due to cavity discharges in China high-speed railways(CHR). The cable termination with cavity defects is used as test samples and a low-temperature PD test system is set up to study the characteristics of partial discharge(PD) of cavity defects in cable termination in those regions. Influences of the different temperatures on internal discharge in EPR insulation at -40°C and 20°C have been analyzed. When the applied temperature dropped to -40°C, the PD initiation voltage and extinction voltage decreased by 31% and 28%, respectively, and the discharge pulse appeared at both positive and negative half-cycles. The results showed that, at 20°C, the discharge was mainly caused by the internal discharge of the gas-filled cavity. Apart from the internal discharge of the gas-filled cavity, a marked trace of surface discharge was also detected at -40°C. Besides, the characteristics of PD development at -40°C are closely related to the discharge phase distribution and the asymmetry of the spectrum. The research can further reveal the development and evolution of partial discharge of the gas-filled cavity, and provide a basis for judging the severity of termination at low temperature.

25 April 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LBLonglei Bai
Longlei Bai
MSMingwei Su
Mingwei Su
LSLiangshun Sun
Liangshun Sun
SFShaogui Fan
Shaogui Fan
SXShuai Xun
Shuai Xun
HPHui Peng
Hui Peng
There is a significant positive proportional correlation between the condition of ethylene propylene diene monomer (EPDM) insulation and partial discharge (PD) characteristics in electric multiple units (EMUs) cable termination. Especially for the cable terminations with long service life, the aging effect of EPDM insulation material is significant due to long-term high-current load. In this article, electrical deterioration and PD development of EPDM insulation under long-term thermal degradation is conducted. During the test process, the phase-resolved PD (PRPD) analysis, PD inception voltage (PDIV), physicochemical properties, and flashover voltage of EPDM samples with different thermal degradation are measured. The relationship between the thermal degradation extent of EPDM insulation and PD characteristics is also proposed. The results show that electrical deterioration of the aged sample can be divided into four gradations by PD amplitude and pulse repetition rate. In the four gradations, the shape of the PRPD spectrum in every gradation changes significantly with different thermal degradations. Surface morphologies of EPDM insulation show different features such as gully areas and white particles. The results of the Fourier transform infrared (FTIR) spectroscopy test indicate that the increase of oxygen-containing groups and free radicals are the key reasons for the rapid PD development process of cable insulation under different electrical gradations and thermal-oxygen degradations.

4 March 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
LBLonglei Bai
Longlei Bai
JYJu Ye
Ju Ye
ZMZhiyong Ma
Zhiyong Ma
ZZZiye Zhang
Ziye Zhang
Chaoqiang JiangChaoqiang Jiang
Chaoqiang Jiang
LSLiangshun Sun
Liangshun Sun
In the realm of underwater wireless power transmission systems, it is crucial to acquire system parameters accurately to ensure output stability. However, measuring these parameters in underwater environments presents a huge challenge. As a result, simplifying measurements through parameter identification becomes essential. The circuit model of the underwater wireless power transfer (WPT) system may require adjustments due to seawater conductivity, and utilizing current parameter identification methods is applicable to air, which can lead to notable inaccuracies in underwater parameter identification. This article presents an analytical model of the mutual inductance in the underwater WPT system, analyzes its impact on output power and transmission efficiency, and proposes a mutual inductance and load parameter identification method suitable for underwater WPT systems. This method identifies mutual inductance and load values by measuring the input impedance of the equivalent load network on the inverter side at both resonant and nonresonant frequencies. The parameter identification model of the proposed underwater WPT system has been theoretically derived and experimentally verified using the seriesseries (SS) compensation topology. The experimental results illustrate that the proposed parameter identification method effectively identifies both the mutual inductance model and the load of the underwater WPT system, with the load identification error being less than 2% and the mutual inductance identification error being less than 5%. Furthermore, mutual inductance and load information can be obtained from the primary side without communication, and the output voltage is controlled with an accuracy of less than 1.2% through parameter identification.

6 June 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Bo LuoBo Luo
Bo Luo
YLYuezhong Liu
Yuezhong Liu
YZYiming Zhang
Yiming Zhang
LBLonglei Bai
Longlei Bai
YZYao Zhang
Yao Zhang
Ruikun MaiRuikun Mai
Ruikun Mai
Electronically controlled pneumatic (ECP) system is essential to ensure the railway transportation system's braking safety. Traditionally, the ECP system needs a long cable to supply power for each train body's brake controller. However, a train has many bumps, and the transmission lines and plugs easily fall off simultaneously. It brings severe challenges to the safe and reliable operation of the railway system. This paper proposes a capacitive power transfer (CPT) system to supply power for a long-distance and multiple-load ECP brake system to solve this problem. The proposed system has the following characteristics: 1. It can supply power to multiple loads simultaneously; 2. The variation of load resistance will not affect the other load; 3. The output of each load will not be largely affected by the coupler misalignment. The transmitter of the proposed CPT system adopts CL compensation, while the receivers adopt LCCL topology. The receiver not only receives the electric power for the load but also transfers the power to the next load. A scaled-down experimental prototype with three loads was implemented to verify the proposed theory. The experimental results agree well with the analysis. With a 200mm misalignment (2/3 length of coupler plates), the output power can reach 83.32W (150W rated). The change rate of the output voltage is less than 12% when other receivers are moved out.