Background: Computed tomography to body divergence (CTBD) is one of the main barriers to bronchoscopic techniques for the diagnosis of peripherally located lung nodules. Cone-beam CT (CBCT) guidance is being rapidly adopted to correct for this phenomenon and to potentially increase diagnostic outcomes. In this trial, we hypothesized that the addition of mobile CBCT (m-CBCT) could improve the rate of tool in lesion (TIL) and the diagnostic yield of shape-sensing robotic-assisted bronchoscopy (SS-RAB). Methods: This was a prospective, single-arm study, which enrolled patients with peripheral lung nodules of 1–3 cm and compared the rate of TIL and the diagnostic yield of SS-RAB alone and combined with mCBCT. Results: A total of 67 subjects were enrolled, the median nodule size was 1.7 cm (range, 0.9–3 cm). TIL was achieved in 23 patients (34.3%) with SS-RAB alone, and 66 patients (98.6%) with the addition of mCBCT (p < 0.0001). The diagnostic yield of SS-RAB alone was 29.9% (95% CI, 29.3–42.3%) and it was 86.6% (95% CI, 76–93.7%) with the addition of mCBCT (p < 0.0001). There were no pneumothoraxes or any bronchoscopy-related complications, and the median total dose–area product (DAP) was 50.5 Gy-cm2. Conclusions: The addition of mCBCT guidance to SS-RAB allows bronchoscopists to compensate for CTBD, leading to an increase in TIL and diagnostic yield, with acceptable radiation exposure.
Peripheral bronchoscopy with the use of thin/ultrathin bronchoscopes and radial-probe endobronchial ultrasound (RP-EBUS) has been associated with a fair diagnostic yield. Mobile cone-beam CT (m-CBCT) could potentially improve the performance of these readily available technologies. We retrospectively reviewed the records of patients undergoing bronchoscopy for peripheral lung lesions with thin/ultrathin scope, RP-EBUS, and m-CBCT guidance. We studied the performance (diagnostic yield and sensitivity for malignancy) and safety (complications, radiation exposure) of this combined approach. A total of 51 patients were studied. The mean target size was 2.6 cm (SD, 1.3 cm) and the mean distance to the pleura was 1.5 cm (SD, 1.4 cm). The diagnostic yield was 78.4% (95 CI, 67.1–89.7%), and the sensitivity for malignancy was 77.4% (95 CI, 62.7–92.1%). The only complication was one pneumothorax. The median fluoroscopy time was 11.2 min (range, 2.9–42.1) and the median number of CT spins was 1 (range, 1–5). The mean Dose Area Product from the total exposure was 41.92 Gy·cm2 (SD, 11.35 Gy·cm2). Mobile CBCT guidance may increase the performance of thin/ultrathin bronchoscopy for peripheral lung lesions in a safe manner. Further prospective studies are needed to corroborate these findings.
Cirrhosis, a marker of severe liver diseases, limits future liver remnant (FLR) growth, preventing many cancer patients from undergoing surgery. While portal vein blockade (PVB) techniques are used to stimulate liver regeneration, 20–30% of patients still fail to achieve the required growth. Although mesenchymal stem cell (MSC) therapy improves PVB, its efficacy is limited by poor cell retention. To address this, we utilized alginate hydrogels to deliver MSCs and improve their retention. MSCs were loaded in the hydrogel and injected intraportally in cirrhotic rats. Liver volume, weights, enzyme levels, and histology were monitored. Results showed that the hydrogel maintained 89.0 ± 3.0% cell viability and gradually released MSCs for over two weeks. Furthermore, the rats injected with the MSC-loaded hydrogel demonstrated higher liver volumes (FLR ratio of 0.57 ± 0.32) and weights (FLR ratio of 0.84 ± 0.05). The treated rats exhibited more improved liver enzymes (AST: 72.75 ± 14.17 U/L, ALP: 135.67 ± 41.20 U/L, ALT: 46.00 ± 2.94 U/L) and decreased fibrotic areas in the liver (4.52 ± 0.22%) compared to the control group. Histology revealed increased retention when MSCs were delivered with the hydrogel (37.30 ± 16.10 MSCs/mm2) compared to cells alone (21.70 ± 22.10 MSCs/mm2). Overall, the MSC-loaded hydrogels enhanced the growth and reduced the fibrosis of the liver by promoting cell retention and efficacy in cirrhotic rats. This approach holds significant potential for improving outcomes among cancer patients, offering a promising therapeutic strategy for liver regeneration and treatment of liver diseases.
Resorbable medical devices provide temporary functionality before degrading into safe byproducts. One application is absorbable inferior vena cava filters (IVCFs), which prevent pulmonary embolism in high-risk patients with contraindications to anticoagulants. However, current absorbable IVCFs are limited by radiolucency and local clot formation risks. This study aimed to develop radiopaque, drug-loaded resorbable IVCFs with enhanced imaging and therapeutic capabilities. Poly-p-dioxanone (PPDO) sutures were infused with gadolinium nanoparticles (GdNPs) and dipyridamole (DPA), an anti-thrombotic agent. GdNPs were synthesized with an average diameter of 35.76 ± 3.71 nm. Gd content was 371 ± 1.6 mg/g (PPDO-Gd) and 280 ± 0.3 mg/g (PPDO-Gd + DPA), while the DPA content was 18.20 ± 5.38 mg/g (PPDO-DPA) and 12.91 ± 0.83 mg/g (PPDO-Gd + DPA). Suture thickness (0.39–0.49 cm, p = 0.0143) and melting temperature (103.61–105.90, p = 0.0002) statistically differed among the different groups, while load-at-break did not (4.39–5.38, p = 0.2367). Although suture thickness and melting temperatures differed significantly, load-at-break was preserved and did not alter the mechanical and degradation properties of the various IVCFs. Micro-computed tomography revealed enhanced radiopacity for Gd-containing IVCFs (2713 ± 105 HU for PPDO-Gd, 1516 ± 281 HU for PPDO-Gd + DPA). Radiopacity decreased gradually over 10–12 weeks. Clot-trapping efficacy was maintained, and no hemolysis or cellular toxicity was observed. In conclusion, the GdNP- and DPA-infused PPDO IVCFs demonstrated improved radiopacity, anti-thrombotic potential, and compatibility with routine imaging, without compromising mechanical strength or safety.