Osvaldo Rodríguez-Quiroz

Dr. Osvaldo Rodríguez-Quiroz

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2018 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
CDCarmen E. Dominguez-Flores
Carmen E. Dominguez-Flores
DMDavid Monzon-Hernandez
David Monzon-Hernandez
JMJosue Israel Moreno-Basulto
Josue Israel Moreno-Basulto
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
Uladzimir (or Vladimir) Petrovich MinkovichUladzimir (or Vladimir) Petrovich Minkovich
Uladzimir (or Vladimir) Petrovich Minkovich
IRIván Hernández Romano
Iván Hernández Romano
A simple to fabricate, cost-effective, robust, and highly accurate fiber optic temperature sensor is proposed and experimentally demonstrated. The sensor head consists of an in-fiber Fabry-Perot interferometer (FFPI) embedded in a mold made of a polyester resin. FFPI, which in general present good strain sensitivity and low temperature sensitivity, was assembled by splicing a microsegment of capillary fiber (CF) of 14.66 μm between two single-mode fibers (SMFs). The reflected spectrum of the FFPI exhibited a single interference dip within a span of 80 nm. The dimensions of the resin mold can be modified by changing the ambient temperature, which in turn changes the length of the FFPI air-cavity. The dip of the reflected spectrum is shifted towards shorter (larger) wavelengths when external temperature is decreased (increased). The large free spectral range (FSR) allowed to monitor the temperature changes by either a wavelength or an intensity interrogation scheme. Using a laser and an optical power meter it was possible to demonstrate a real-time temperature sensor with a sensitivity of -60.79 nW/°C and a resolution of 0.5 °C, in the range of 10-30 °C. We believe that the practicality of this real-time sensor can be very attractive for environmental sensing application.

9 July 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CDCarmen E. Dominguez-Flores
Carmen E. Dominguez-Flores
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
DMDavid Monzon-Hernandez
David Monzon-Hernandez
JAJoaquin Ascorbe
Joaquin Ascorbe
Jesús M. CorresJesús M. Corres
Jesús M. Corres
FAFrancisco J. Arregui
Francisco J. Arregui
An optical fiber tip interferometer for the measurement of relative humidity (RH) and temperature is proposed. The optical fiber structure used, a dual-cavity optical fiber Fabry-Perot interferometer (DFFPI), is simply-to-fabricate, compact, and robust. The reflectance (RDFFPI) of the interferometer is sensitive to the refractive index (RI) and temperature of the external medium. Consequently, when the cross-section of the fiber tip was coated with a SnO2 thin film, whose RI changes according to the humidity of the surrounding ambient, the measurement of the RH was possible. An increment of the RH produced a decrement of RI of the SnO2 thin film, then the reflectance of the fiber tip end-face diminished, and this produced a decrement of the visibility of the interference fringes. The analysis of the RDFFPI was carried out in the Fourier domain, using a novel processing method it was possible to establish that the amplitude of two peaks of Fourier spectrum changed at a ratio of 39.49x10-3 %RH-1 in the range of 40 to 90 RH%. On the other hand, the temperature of the humidity chamber was monitored, from 25 to 60 °C at a fixed RH%, by analyzing the phase shift of the interference pattern produced by the changes in the optical path length of the cavities. The good sensitivity, stability, reproducibility, and compactness of the fiber tip RH sensor make this proposal very appealing in a wide range of applications.

13 June 2019 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
CDCarmen E. Dominguez-Flores
Carmen E. Dominguez-Flores
DMDavid Monzon-Hernandez
David Monzon-Hernandez
CMCarlos Moreno-Hernandez
Carlos Moreno-Hernandez
The reflectance of a hybrid fiber Fabry-Perot interferometer (HFFPI) modulated by the Fresnel reflection at the fiber tip was used to assess the refractive index (RI) of liquid samples. Notwithstanding the closeness of RI values between samples and fiber core, well-defined interference spectra in Fourier domain were obtained after a robust signal processing algorithm. Then, the analysis of these spectra allowed us to derive a mathematical expression to obtain the RI value of the fiber tip surrounding media. Next, to assess the fiber refractometer measuring capability a series of liquid samples, typically used for RI calibration, with values ranging from 1.3924 to 1.5882 were measured. A standard deviation of $7 \text{x} 10^{-4}$ between the measured and actual RI values was estimated. Finally, the refractometer was used to monitor the RI of a sample, with a high thermo-optic coefficient (TOC), while it was heated. The accurate and compact all-fiber refractometer proposed here exhibited immunity to optical power fluctuations and one of the largest dynamic ranges reported. This set of combined features make it very attractive for real-time label-free biosensing applications.

1 August 2020 in Optics & Laser Technology
Verified
Journal Article
Closed access
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
CDCarmen E. Domínguez-Flores
Carmen E. Domínguez-Flores
DMDavid Monzón-Hernández
David Monzón-Hernández
Eden Morales-NarváezEden Morales-Narváez
Eden Morales-Narváez
VMVladimir P. Minkovich
Vladimir P. Minkovich
DLDaniel López-Cortés
Daniel López-Cortés

19 November 2020 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
CDCarmen E. Dominguez-Flores
Carmen E. Dominguez-Flores
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
DMDavid Monzon-Hernandez
David Monzon-Hernandez
In this work, we propose a signal processing algorithm to enlarge the refractive index dynamic range (RIDR) of the Fresnel reflection-based fiber Fabry-Perot (FR-FFP) sensors. In this approach, the reflected spectrum of the FR-FFP interferometer is modulated by an impulse function. The processed optical spectrum includes the superposition of the original wavelength-modulated interference pattern and an ultra-narrow peak, produced by the impulse function. The wavelength of that peak coincides with a maximum of the interference fringe. In Fourier domain, the spectrum exhibits the characteristic interference peaks superimposed to a broad step. In Fourier domain the amplitude of one of the interference peaks is modulated by refractive index (RI) of the external medium, but the amplitude of the step is not affected. It was possible to stablish a simple correspondence between the amplitude of the interference peak and the RI of the external medium in a wide dynamic range [1.000, 2.000]. The inclusion of the impulse function, which produces the step in the Fourier domain, eliminates the RI ambiguity of the FR-FFPI allowing the enlargement of the RIDR.

1 February 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
JRJose Rodriguez-Delgado
Jose Rodriguez-Delgado
Juan Francisco Villarreal-ChiuJuan Francisco Villarreal-Chiu
Juan Francisco Villarreal-Chiu
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Glycine is an essential amino acid involved in synthesizing a variety of important biomolecules, and its concentration can influence numerous biochemical processes, including the severity of symptoms in a wide range of conditions in humans, such as cancer, schizophrenia, major depression, and diabetes. While a few costly or labour-intensive methods are currently available, we have developed a new enzymatic biosensor that can accurately measure glycine levels with remarkable simplicity. By employing immobilized laccase enzymes in combination with a surface plasmon resonance (SPR) device, our system achieved a limit of detection (LOD) of 9.95 mM and a limit of quantification (LOQ) of 33.19 mM. In addition, it demonstrated a recovery rate of 97.64 ± 7.71%. Moreover, the biosensor maintained consistent signal intensity over 21 days and supported a total of 60 analyses using the same immobilized enzyme setup, demonstrating excellent reusability. Notably, this study marks the first time glycine has been determined using an enzymatic SPR-based platform.