The present study investigated the effectiveness of electromagnetic fields in preventing calcium carbonate (CaCO3) fouling in cooling water. Four different frequencies and two different voltages were adopted to induce electromagnetic fields directly in water with constant water temperature and constant flow velocity. Artificial hard water was used. The solution conductivities decreased by 17–25% from their initial values in the electromagnetic anti-fouling treatment (EAT) cases, depending on different frequencies of electric pulses, whereas the untreated case dropped by 31%. The particle size became small and the crystal structure changed into loose style after EAT. The EAT device independently developed by the State Key Laboratory had been validated as an effective apparatus in preventing CaCO3 fouling in cooling water.
The reliability and service life of power cables is closely related to the cable ampacity and temperature rise. Therefore, studying the temperature field distribution and the cable ampacity is helpful to improve the construction guidelines of cable manufacturers. Taking a 8.7/15 kV YJV 1 × 400 XLPE three-loop power cable as the research object, cable temperature is calculated by IEC-60287 thermal circuit method and numerical simulation method, respectively. The results show that the numerical simulation method is more in line with the actual measured temperature, and the relative error is only 0.32% compared with the actual measured temperature. The temperature field and air velocity field of cluster cables with different laying methods are analyzed by finite element method. The corresponding cable ampacity are calculated by secant method. The results show that when the cable is laid at the bottom of the cable trench, the cable current is 420 A, which is 87.5% of the regular laying. Under irregular laying mode, the temperature of cable is higher than that of regular laying mode and the cable ampacity is lower than that of regular laying mode. At the same time, a multiparameter online monitoring system is developed to online monitor the temperature, water level and smoke concentration of the cable.
The advent of smart grids has facilitated data-driven methods for detecting electricity theft, with a preponderance of research efforts focused on user electricity consumption data. The multi-dimensional power state data captured by Advanced Metering Infrastructure (AMI) encompasses rich information, the exploration of which, in relation to electricity usage behaviors, holds immense potential for enhancing the efficiency of theft detection. In light of this, we propose the Catch22-Conv-Transformer method, a multi-dimensional feature extraction-based approach tailored for the detection of anomalous electricity usage patterns. This methodology leverages both the Catch22 feature set and complementary features to extract sequential features, subsequently employing convolutional networks and the Transformer architecture to discern various types of theft behaviors. Our evaluation, utilizing a three-phase power state and daily electricity usage data provided by the State Grid Corporation of China, demonstrates the efficacy of our approach in accurately identifying theft modalities, including evasion, tampering, and data manipulation.
Overhead ground wires typically have strong axial tension and are prone to structural defects caused by corrosion and lightning strikes, which could lead to serious safety hazards. Therefore, it is important to detect defects accurately and quickly to avoid those problems. Existing defect detection methods for overhead ground wires are mainly traditional metal defect detection methods, including eddy current detection, ultrasonic detection, and manual visual inspection. However, those methods have problems of low detection efficiency, high environmental requirements, and insufficient reliability. To solve the above problems, this paper studies a novel type of defect detection technology for overhead ground wire. Firstly, the magnetic leakage characteristics around the defects of overhead ground wires are analyzed, and the defect detection device is designed. Then, the influence of air gap, lift-off distance, defect width, and cross-sectional loss rate on the magnetic flux leakage signal is studied, a novel defect detection method for overhead ground wire is proposed, and experimental verification is carried out. The results show that the proposed method can accurately locate and quantify the defect, which has the advantages of good reliability and high efficiency and lays the foundation for preventing accidents caused by defective overhead ground wires.
Electricity theft is a major source of non-technical losses in distribution networks, threatening both economic revenues and power supply reliability. This study addresses the identification of nodes exhibiting anomalous load behavior (anomalous nodes) in 10 kV distribution feeders. Based on the IEEE-33 bus benchmark system, the disturbance patterns induced by abnormal consumption are analyzed. The results show that voltage and current fluctuations intensify with increasing electrical distance from the power source, while branch loss peaks localize at the affected terminals and propagate unidirectionally along the power flow path. Building on these findings, an improved density-based spatial clustering of applications with noise (DBSCAN) method is proposed, integrating five spatial network features and sixteen temporal electrical features extracted from voltage, current, and power series. Prior to clustering, the features are standardized and reduced via principal component analysis (PCA), retaining over 90% of the cumulative variance. Validation on a hybrid dataset demonstrates that the proposed method achieves 90.7% accuracy, 87.5% recall, and an F1-score of 0.895, outperforming traditional K-means and approaching supervised CNN models without requiring labeled data. These results confirm the method’s robustness and suitability for practical deployment in distribution networks.
The lung is one of the most vital organs in the human body, and its condition is closely correlated with overall health. Electrical impedance tomography (EIT), as a biomedical imaging technique, often produces low-quality reconstructed images due to its inherent ill-posedness in solving the inverse problem. To address this issue, this paper proposes a soft-threshold region segmentation algorithm with a relaxation factor. This algorithm segments the reconstructed lung images into internal regions, edge regions, and background regions, resulting in clearer boundaries in the reconstructed images. This facilitates the intuitive identification of regions of interest by healthcare professionals. Additionally, this segmentation algorithm is suitably combined with a dimension-reduced Tikhonov regularization algorithm. By utilizing the joint capabilities of these algorithms, the partition points belonging to the background region can be excluded from the sought grayscale vector, thereby improving the ill-posedness of the image reconstruction process and enhancing the quality of image reconstruction. Finally, a 16-electrode human lung EIT simulation model is established for the thoracic region and verified through simulation. Experimental validation is conducted using a human lung tank simulation platform to further demonstrate the effectiveness of the proposed method.