Yongye Wu

Dr. Yongye Wu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2021 in Actuators
Verified
Journal Article
Open access
PDF file
YWYongye Wu
Yongye Wu
Zhanlong ZhangZhanlong Zhang
Zhanlong Zhang
RXRui Xiao
Rui Xiao
PJPeiyu Jiang
Peiyu Jiang
ZDZijian Dong
Zijian Dong
JDJun Deng
Jun Deng
The converter transformer is a special power transformer that connects the converter bridge to the AC system in the HVDC transmission system. Due to the special structure of the converter transformer, it is necessary to test its operation state during its manufacture and processing to ensure the safety of its future connection to the grid. Numerous studies have shown that vibration signals in transformers can reflect their operating state. Therefore, in order to achieve an effective identification of the operation state of the converter transformer, this paper proposes a method for identifying the operation state of the converter transformer based on vibration detection technology and a deep belief network optimization algorithm. This paper firstly describes the background, principle and application of vibration detection technology, using vibration measurement systems with piezoelectric acceleration sensors, piezoelectric actuators and data acquisition instruments to collect vibration signals at different measurement points on the converter transformer in states of no-load and on-load. By analyzing the time-frequency characteristics of the vibration signals, fast Fourier transform (FFT), wavelet packet decomposition (WPD) and time domain indexes (TDI) are combined into a fused feature extraction method to extract the eigenvalues of the vibration signals, so that the fused eigenvectors of the signals can be constructed. Considering the excellent performance of deep learning in classification, the deep belief network is used to classify the signals’ eigenvectors. To effectively improve the network classification efficiency, the sparrow search algorithm was introduced to build a mathematical model based on the behavioral characteristics of sparrow populations and combine the model with a deep belief network, so as to achieve adaptive parameter optimization of the network and accurate classification of the signals’ eigenvectors. The proposed method is applied to a 500 kV converter transformer for experimental verification. The experimental results show that the fused feature extraction method was able to fully extract the features of the vibration signal, and the deep belief network optimization algorithm had higher classification accuracy and better operational efficiency, and was able to effectively achieve accurate identification of the operation state of the converter transformer. In addition, the method achieved a precision response to the detection results of the vibration sensors, contributing to future improvements in converter transformer manufacturing technology.

21 March 2019 in Mathematics
Verified
Journal Article
Open access
PDF file
Zhanlong ZhangZhanlong Zhang
Zhanlong Zhang
YWYongye Wu
Yongye Wu
RZRuixuan Zhang
Ruixuan Zhang
PJPeiyu Jiang
Peiyu Jiang
GLGuohua Liu
Guohua Liu
ZDZijian Dong
Zijian Dong
Most power transformer faults are caused by iron core and winding faults. At present, the method that is most widely used for transformer iron core and winding faults identification is the vibration analysis method. The vibration analysis method generally determines the degree of fault by analyzing the energy spectrum of the transformer vibration signal. However, the noise reduction step in this method is complicated and costly, and the effect of denoising needs to be further improved to make the fault identification results more accurate. In addition, it is difficult to perform an accurate determination of the early mild failure of the transformer due to the effect of noise on the results. This paper presents a novel mathematical statistics method based on the vibration signal to optimize the vibration analysis method for the short-circuit failure of the transformer winding. The proposed method was used for linear analysis of the transformer vibration signal with different degrees of short-circuit failure of the transformer winding. By comparing the slope value of the transformer vibration signal cumulative probability distribution curve and analyzing the energy spectrum of the signal, the degree of short-circuit failure of the transformer winding was identified quickly and accurately. This method also simplified the signal denoising process in transformer fault detection, improved the accuracy of fault detection, reduced the time of fault detection, and provided good predictability for early mild faults of the transformer, thereby reducing the hidden hazards of operating the power transformer. The proposed optimization procedure offers a new research idea in transformer fault identification.

12 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YDYouquan Dai
Youquan Dai
Zhanlong ZhangZhanlong Zhang
Zhanlong Zhang
ZDZijian Dong
Zijian Dong
YWYongye Wu
Yongye Wu
ZGZhihao Gao
Zhihao Gao
The detection of corona-related defects in transmission lines has been included in the work of transmission line defect detection. Ultraviolet detection technology has gradually been widely applied in the field of corona discharge detection. However, the current research on the application of ultraviolet detection technology in transmission lines is relatively simple and mainly limited to using changes in the photon count to determine whether corona discharge has occurred. To address this, this study used a mini corona cage to simulate transmission lines and measured the changes in the photon count, spot area, and corona current in the corona inception process of different types of smooth, stainless-steel conductors. This study also investigated the variations in the photon count and spot area depending on conductor corona intensity, ultraviolet imager gain, and observation distance. The results show that the photon count and spot area can, to some extent, reflect the intensity of corona discharge. Both the photon count and spot area exhibited quadratic relationships with the voltage. As the observation distance increased, both the photon count and spot area showed exponential decay. The photon count exhibited a trend of initially increasing, then decreasing, and finally increasing again with the increase of gain, while the spot area showed exponential growth with increasing gain. The photon count and spot area can complement each other to identify and characterize the intensity of corona discharge.

15 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YSYang Song
Yang Song
LXLan Xiong
Lan Xiong
ZLZhenyou Liu
Zhenyou Liu
YWYongye Wu
Yongye Wu
Zhanlong ZhangZhanlong Zhang
Zhanlong Zhang
The lung is one of the most vital organs in the human body, and its condition is closely correlated with overall health. Electrical impedance tomography (EIT), as a biomedical imaging technique, often produces low-quality reconstructed images due to its inherent ill-posedness in solving the inverse problem. To address this issue, this paper proposes a soft-threshold region segmentation algorithm with a relaxation factor. This algorithm segments the reconstructed lung images into internal regions, edge regions, and background regions, resulting in clearer boundaries in the reconstructed images. This facilitates the intuitive identification of regions of interest by healthcare professionals. Additionally, this segmentation algorithm is suitably combined with a dimension-reduced Tikhonov regularization algorithm. By utilizing the joint capabilities of these algorithms, the partition points belonging to the background region can be excluded from the sought grayscale vector, thereby improving the ill-posedness of the image reconstruction process and enhancing the quality of image reconstruction. Finally, a 16-electrode human lung EIT simulation model is established for the thoracic region and verified through simulation. Experimental validation is conducted using a human lung tank simulation platform to further demonstrate the effectiveness of the proposed method.