Feng Guojin

Dr. Feng Guojin

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2017 in Materials
Verified
Journal Article
Open access
PDF file
HSHaibin Sun
Haibin Sun
JXJiamin Xiao
Jiamin Xiao
SZSuwan Zhu
Suwan Zhu
YHYue Hu
Yue Hu
FGFeng Guojin
Feng Guojin
LZLi Zhao
Li Zhao
Femtosecond (fs)-laser hyperdoped silicon has aroused great interest for applications in infrared photodetectors due to its special properties. Crystallinity and optical absorption influenced by co-hyperdoped nitrogen in surface microstructured silicon, prepared by fs-laser irradiation in gas mixture of SF6/NF3 and SF6/N2 were investigated. In both gas mixtures, nitrogen and sulfur were incorporated at average concentrations above 1019 atoms/cm3 in the 20–400 nm surface layer. Different crystallinity and optical absorption properties were observed for samples microstructured in the two gas mixtures. For samples prepared in SF6/N2, crystallinity and light absorption properties were similar to samples formed in SF6. Significant differences were observed amongst samples formed in SF6/NF3, which possess higher crystallinity and strong sub-band gap absorption. The differing crystallinity and light absorption rates between the two types of nitrogen co-hyperdoped silicon were attributed to different nitrogen configurations in the doped layer. This was induced by fs-laser irradiating silicon in the two N-containing gas mixtures.

11 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XLXufeng Liu
Xufeng Liu
ZZZhenyuan Zhang
Zhenyuan Zhang
FGFeng Guojin
Feng Guojin
Based on parallel light, a device for measuring sample emissivity under vacuum and low temperature was established. In this paper, a new emissivity measurement formula was designed, which replaces the derivation of Kirchhoff’s law of thermal radiation. The device is designed with a light-weight blackbody, an improved cooling speed, and an improved PID temperature control system to achieve a good temperature stability, close to 1 mK. The device is capable of measuring within a wavelength range of 4 μm to 16 μm. The results of the uncertainty assessment show that the uncertainty of the normal emissivity is better than 1.6% in the range of 4 μm to 7 μm, and better than 0.6% in the range of 7 μm to 14 μm (k = 1) at 0 °C.

1 January 2020 in Journal of Applied Optics
Verified
Journal Article
Closed access
PDF file
MYMa Yuxuan
Ma Yuxuan
FGFeng Guojin
Feng Guojin
LZLiu Zilong
Liu Zilong
ZQZhang Qiaoxiang
Zhang Qiaoxiang
ZCZheng Chundi
Zheng Chundi
LYLi Yuxiao
Li Yuxiao
In order to study the influence of different microstructures on the plane blackbody reflectance, 40 kinds of plane blackbody samples with surface microstructures composed of different cone gear types (square cone and circular cone), height and density were designed. The same process was adopted on the samples surface, and the same type of surface absorption coating was sprayed to reduce the surface reflection. The reflectance of the samples in the visible and near-infrared bands was measured by the spectrometer. The measurement results show that the microstructure can reduce the reflectance from 1.4% in the plane state to nearly 0.4%. When other conditions are consistent, the higher the height of the cone gear and the denser the cone gear, the lower the reflectance of the plane blackbody; different cone gear types have no significant effect on the reflectance; compared with the simulation value obtained by the Tracepro, the higher the height of the cone gear, the denser the cone gear surface, the greater the relative error, and the relative error is in the range of 10% ~ 65%.

2 October 2025 in Thermo
Verified
Journal Article
Open access
PDF file
TLTianshuo Li
Tianshuo Li
ZZZhenyuan Zhang
Zhenyuan Zhang
FGFeng Guojin
Feng Guojin
XCXinhua Chen
Xinhua Chen
ZHZiqi Hao
Ziqi Hao
Infrared thermography for human skin temperature measurement, when calibrated with standard blackbodies, suffers from errors due to the mismatch in emissivity between a blackbody and human skin. This study introduces a novel calibration method utilizing a human skin-like gradient radiation source to enhance measurement accuracy. A custom radiation source with six temperature points and skin-like emissivity was developed. Thermal imagers were calibrated using this source, and their performance was compared against traditional blackbody calibration. The proposed method reduced the calibration error to 0.04 °C, a significant improvement over the 0.15 °C error obtained with blackbody calibration. Calibration with a skin-like radiation source proves superior to the blackbody method, enabling high-accuracy (less than 0.1 °C) human skin temperature measurement for improved fever screening.

19 July 2025 in Materials
Verified
Journal Article
Open access
PDF file
SHShufang He
Shufang He
SLShuai Li
Shuai Li
CDCaihong Dai
Caihong Dai
JLJinyuan Liu
Jinyuan Liu
YWYanfei Wang
Yanfei Wang
JWJinghui Wang
Jinghui Wang
Measuring the emissivity of an infrared radiant sample with high accuracy is important. Previous studies reported on the multi- or two-temperature calibration methods, which used a reference blackbody (or blackbodies) to eliminate the background radiation, and assumed that the background radiation was independent of temperature. However, in practical measurements, this assumption does not hold. To solve the above problems, this study proposes a modified two-temperature calibration method and facility. The two temperature points are set in a certain small interval based on the proposed calculation method; based on the indication of the approximation that the emissivities of the sample and the background radiations remain the same at these two temperatures, the emissivities can be calculated with measurement signals at these two temperatures, and a reference blackbody is not needed. An experimental facility was built up and three samples with emissivities around 0.100, 0.500, and 0.900 were measured in (8~14) μm. The relative expanded uncertainties were 9.6%, 4.0%, and 1.5% at 60 °C, respectively, and 8.8%, 5.8%, and 1.2% at 85 °C (k = 2), respectively. The experimental results showed consistency with the results obtained using other methods, indicating the effectiveness of the developed method. The developed method might be suitable for samples whose emissivities are temperature insensitive.

3 November 2010
Verified
Conference Paper
Closed access
FGFeng Guojin
Feng Guojin
YWYu Wang
Yu Wang
PLPing Li
Ping Li
CZChundi Zheng
Chundi Zheng
QZQiaoxiang Zhang
Qiaoxiang Zhang
YHYingwei He
Yingwei He
In the progress of wavenumber traceability using polystyrene films, different peak-seeking algorithms are discussed in this paper. Conclusion shows that in commonly used methods, spline method, center of gravity method and the second derivative method, spline method is better than the others with simple algorithm and good agreement. It is strongly recommended to use in practical for calibrating FTIR spectrometer.