We aimed to assess the crystallography, microstructure and flexural strength of zirconia-based ceramics made by stereolithography (SLA). Two additively manufactured 3 mol% yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP: LithaCon 3Y 230, Lithoz; 3D Mix zirconia, 3DCeram Sinto) and one alumina-toughened zirconia (ATZ: 3D Mix ATZ, 3DCeram Sinto) were compared to subtractively manufactured 3Y-TZP (control: LAVA Plus, 3M Oral Care). Crystallographic analysis was conducted by X-ray diffraction. Top surfaces and cross-sections of the subsurface microstructure were characterized using scanning electron microscopy (SEM). Biaxial flexural strength was statistically compared using Weibull analysis. The additively and subtractively manufactured zirconia grades revealed a similar phase composition. The residual porosity of the SLA 3Y-TZPs and ATZ was comparable to that of subtractively manufactured 3Y-TZP. Weibull analysis revealed that the additively manufactured LithaCon 3Y 230 (Lithoz) had a significantly lower biaxial flexural strength than 3D Mix ATZ (3D Ceram Sinto). The biaxial flexural strength of the subtractively manufactured LAVA Plus (3M Oral Care) was in between those of the additively manufactured 3Y-TZPs, with the additively manufactured ATZ significantly outperforming the subtractively manufactured 3Y-TZP. Additively manufactured 3Y-TZP showed comparable crystallography, microstructure and flexural strength as the subtractively manufactured zirconia, thus potentially being a good option for dental implants.
Background: Facial impression methods have been used to fabricate auricular prostheses; however, deformation due to the weight of the impression material remains. This study aimed to investigate the accuracy of auricular three-dimensional (3D) data obtained using a 3D optical extraoral scanner and an intraoral scanner compared with that of a conventional facial impression method. Methods: Six auricles were digitized using an extraoral scanner with and without a reference board around the auricle and an intraoral scanner. Auricle casts fabricated using auricle impressions were scanned using a laboratory scanner. All obtained data were superimposed, and the 3D deformations of the different methods were evaluated using measurement mapping and root mean square (RMS) values. The length, width, and height of the auricular casts and scanned data were measured and compared with the sizes of the original auricles measured using a caliper. Results: Large displacements of the back and margins of the ears were observed, and the RMS values ranged from 0.5–2.4 mm. Larger widths and smaller heights of the scanned and impression data were observed compared to the anthropometric ear data. Conclusions: The study concluded that the fabrication of auricular prostheses using optical scanning is clinically acceptable. All examined scanning techniques demonstrated discrepancies within acceptable limits when compared to the conventional facial impression method.