The WHO has classified Helicobacter pylori as a group 1 carcinogen for stomach cancer since early 1994. However, despite the high prevalence of Helicobacter pylori infection, only about 3% of infected people eventually develop gastric cancer.Biomolecular detections of Helicobacter pylori(HP) were compared using specially modified sensors and fluorine immobilized on a carbon nanotube (HFCNT) electrode, which yielded sensitive results. Handheld voltammetric circuits were used for optimization. An anodic voltammogram of HP molecular oxidation was obtained at 0.0 V ± 0.1 (versus the Ag/AgCl/KCl) in a 0.1 ± 0.2 M NH4H2PO4 electrolyte solution. Under optimized conditions, the analytical working range was 2.98 × 103–22.127 × 10−3 CFU/mL HP using square wave (SW) stripping voltammetry, precision of R2 = 0.9857 ± 0.0005 (SWSV), the detection limit approached to 2.5 × 102 CFU/mL HP (S/N = 3).The developed techniques have been applied to diagnosis of early-stage HP infections using stomach tissue from healthy humans and gastric patients.
COVID-19 antibody detection is dependent on highly specialized, time-consuming techniques, such as PCR separation, DNA amplification, and other methods such as spectrophotometric absorption. For these reasons, specialized technical training is necessary because individual diagnostic treatment is difficult. We have attempted to perform rapid sensing with a detection time of only 30 s. Additionally, we used a wearable multi-layer graphene oxide nanocolloid synthetic skin tattoo probe assay for influenza and COVID-19 virus detection with an electrochemical antigen–antibody redox ionic titration circuit. Cyclic voltametric−2 V~2.0 V potential windows were used. The diagnostic detection limit was determined using stripping anodic and cathodic amplifiers, and the working probe was fabricated with a graphene molecule structure with a virus antigen-immobilized amplifier. With redox potential strength obtained within −1.0 V~−1.3 V ionic activity, anodic and cathodic current linearly increased in the phosphate-buffered saline 5 mL electrolyte. The results indicate that instant detection was enabled via individual and wearable tattoo sensors.
Background/Objective: In-vivo d iabetes detection of glucose were sought using square-wave anodic stripping voltammetry (SW), with bismuth-immobilized carbon nanotube paste electrode (BCE). Methods: The optimum analytical results indicated sensitive peak signals on the BCE. The raw voltammogram was approached within the 1 mgL-1-14 mgL-1 and 10 ugL-1-140 ugL-1, detection limits with preconcentration times of 100 and 200 sec. Results: The relative standard deviation was 0.02 % (n = 15) of 10.0 mgL-1 under optimum conditions. The analytical detection limit (S/N) was attained at 8 ugL-1. The handmade microsensor was directly used in vivo on the living fish brain and human urine.Conclusion: The method was applied at real time in vivo, without requiring any pretreatment and other ionic electrolyte solutions. It can be used for medicinal and other materials requiring biological-fluid detection in real time. This study was designed to be suitable for real-time unmanned remote diagnosis and therapeutic drug injection into the body, micro-needle long-term administration, wearable artificial skin tattoo sensor, and real-time control. In addition, the glasses monitor was designed to be suitable for multitasking and multi-user control.
Background/Objective; In-vivo diabetes detection of glucose were sought using square-wave anodic stripping voltammetry (SW), with bismuth-immobilized carbon nanotube paste electrode (BCE). Methods:The optimum analytical results indicated sensitive peak signals on the BCE. The raw voltammogram was approached within the 1mgL-1-14mgL-1 and 10ugL-1-140 ugL-1, detection limits with preconcentration times of 100 and 200 sec. Results:The relative standard deviation was 0.02 % (n=15) of 10.0 mgL-1 under optimum conditions. The analytical detection limit (S/N) was attained at 8 ugL-1. The handmade microsensor was directly used in vivo on the living fish brain and human urine. Conclusion: The method was applied at real time in vivo, without requiring any pretreatment and other ionic electrolyte solutions. It can be used for medicinal and other materials requiring biological-fluid detection in real time. This study was designed to be suitable for real-time unmanned remote diagnosis and therapeutic drug injection into the body, micro-needle long-term administration, wearable artificial skin tattoo sensor, and real-time control. In addition, the glasses monitor was designed to be suitable for multitasking and multi-user control.